ProMinent is a German dosing and water-treatment technology company whose history begins in 1960 with Chemie & Filter GmbH in Heidelberg.The brand is influential in chemical metering, disinfection, sensors, controllers, and packaged dosing systems where accurate dosage, safety interlocks, and online measurement determine treatment stability.

Prominent Sensors's position in instrumentation and sensors is defined by product families such as Reliable sensors.The portfolio is best understood inside online water-quality measurement, process control, chemical dosing feedback, plant monitoring, and safety interlocks, where engineers compare the technology route, family boundaries, and duty fit before narrowing to individual models.

Representative series on this page include DULCOTEST LF/LFT/LFTK, DULCOTEST PHEI 112 pH and DULCOTEST RHES Pt SE.Engineers should compare measured parameter, range and accuracy, wetted materials, calibration workflow, and control-system communication.

20

Indexed models

2

Product families

0

Subgroups

Model index

Dong san pham va huong dan lua chon

Cach chon Instrumentation & Sensors cua Prominent Sensors

Phan nay tra loi hai cau hoi: Prominent Sensors co nhung dong san pham chinh nao, va can so sanh nhung thong so nao truoc khi chon model cu the.

Buoc 1: Chon dong san pham theo ung dung

Cac dong san pham chinh tren trang nay gom Reliable sensors and General. Hay chon dong phu hop voi muc tieu xu ly, dang thiet bi va dieu kien van hanh truoc, sau do dung chi muc model ben duoi de so sanh thong so cu the.

Buoc 2: Xac nhan model bang thong so chinh

Sau khi chon dong san pham, hay so sanh measurement parameter, sample condition, signal integration, and maintenance frequency. Du an thay the cung phai kiem tra dieu kien lap dat, giao dien va kha nang tuong thich voi he thong hien huu; du an moi can xem them cach van hanh, bao tri va nguon phu tung hoac vat tu.

Product family overview

2 product familys on this page.

Reliable sensors

19 models in this family. Representative models: DULCOTEST LF/LFT/LFTK, DULCOTEST PHEI 112 pH, DULCOTEST RHES Pt SE.

General

1 model in this family. Representative models: Prominent dulco turb c en L.Prominent dulco turb c en L.

Quick Model Index

Fast lookup for 20 indexed products

Search models, families, applications, or parameters; compare 2–4 candidates, save or export the shortlist, and open it on another device by link or QR code.

Products & documents

Showing 20 of 20 models

Select 2–4 models to compare. Your shortlist is saved on this device and can travel by link or QR code.

Ask with selected models

DULCOTEST LF/LFT/LFTK

Reliable sensors

Measuring range: approx. 0.01 ... 20 mS/cm · Electrical connection on the measuring device: 2- or 4-wire measuring line · Operating temperature: -5 ... 50 °C

The DULCOTEST LF/LFT/LFTK is a conductivity sensor for measuring electrolytic conductivity in aqueous media, featuring epoxy resin shafts and special graphite electrodes.

DetailsPDF

DULCOTEST PHEI 112 pH

Reliable sensors

pH-range: 0 … 14 (1 … 12 for optimum service life) · Operating temperature: 0 ... 80 °C · Maximum pressure: 6 bar

The DULCOTEST PHEI 112 pH sensor is designed for general water applications in industrial and municipal wastewater, cooling water, process water.

DetailsPDF

DULCOTEST RHES Pt SE

Reliable sensors

Redox voltage: -1000 ... +1000 mV · Operating temperature: 0 ... 60 °C · Maximum pressure: 3.0 bar

The DULCOTEST RHES Pt SE is a redox sensor designed for applications such as swimming pool, whirlpool, and drinking water treatment.

DetailsPDF

DULCOTEST RHEIC Pt SE

Reliable sensors

Electrical connection: SN6 plug-in head, rotatable with a ProMinent cable · ORP voltage: -1500 ... +1500 mV · Temperature: 0 … 80 °C

The DULCOTEST RHEIC Pt SE is a potentiometric sensor for measuring ORP in various water applications, including wastewater, cooling water, and process water.

DetailsPDF

DULCOTEST BCR

Reliable sensors

Temperature: 5 to 45 °C (BCR 1-mA, BRE 3-CAN-P) or 1 to 40 °C (CBR 1-mA, CBR 1-CAN-P) · Max. pressure: 1.0 bar (BCR 1-mA, CBR 1-mA, CBR 1-CAN-P) or 3.0 bar (BRE 3-CAN-P) · Intake flow: 30 to 60 l/h

DULCOTEST BCR sensors measure total available bromine from BCDMH and other oxidative disinfectants, as well as total chlorine in contaminated water up to pH 9.5.

DetailsPDF

DULCOTEST CDE

Reliable sensors

Selection cues: measuring range · accuracy · output signal and process connection

The Prominent Sensors DULCOTEST CDE is a standard, membrane-covered amperometric sensor for measuring chlorine dioxide in clear, uncontaminated drinking water.

DetailsPDF

DULCOTEST CLB

Reliable sensors

General Measuring Ranges: 0.01 – 200 mg/l, special measuring range up to 1,000 mg/l · Temperature Compensation: Integrated in most models, except for CLE 3-DMT and CLB series · Intake Flow: 30–60 l/h

The DULCOTEST CLB is a cost-effective amperometric sensor for measuring free chlorine in clear water and electrolysis processes. It operates at a maximum pressure of 3.

DetailsPDF

DULCOTEST DO

Reliable sensors

Temperature: 0 … 50 °C · Intake flow: Minimum: 0.05 m/s

The Prominent Sensors DULCOTEST DO sensors are designed for measuring dissolved oxygen in water.

DetailsPDF

DULCOTEST FLEP 010 0100 SE

Reliable sensors

pH range: 5.5 – 9.5 (optimized up to pH 9.5) · Electrical connection: SN6 plug-in head · Temperature: 1 – 35 °C

The DULCOTEST FLEP 010-SE and FLEP 0100-SE are potentiometric fluoride sensors utilizing a LaF₃ crystal for direct measurement.

DetailsPDF

DULCOTEST PER

Reliable sensors

Measuring ranges: 20 ppm to 100,000 ppm (10%). Specific orderable range: 20.0…2,000.0 mg/l. Measuring ranges up to 100,000 ppm available on request · Measuring range: 1...20, 10...200, 100...2000 mg/l, switchable · With 20 mg/l range: 5 µS/cm

The DULCOTEST PER is an amperometric sensor for measuring hydrogen peroxide in various water applications, offering precise real-time analysis.

DetailsPDF

DULCOTEST PHEE

Reliable sensors

pH-range: 1...12 · Temperature: 0...60 °C · Diaphragms: 3 ceramic diaphragms

This Prominent Sensors DULCOTEST PHEE 112 S is a pH combination probe designed for semi-solid or pasty media such as foodstuffs. It features three ceramic diaphragms.

DetailsPDF

DULCOTEST RHEN Pt SE

Reliable sensors

Redox voltage/ORP: -1000...+1000 mV · Medium temperature: 0...80 °C · Conductivity: > 150 µS/cm

The DULCOTEST RHEN Pt SE is a redox combination probe with a platinum metal electrode and ceramic diaphragm designed for wastewater applications.

DetailsPDF

DULCOTEST OZE

Reliable sensors

Temperature range: 5 … 40 °C · pH range: 4.0 … 11.0 · Measuring range: 0.02…2.0 mg/l

The DULCOTEST OZE is a sensor line designed for measuring ozone in water. Available in OZE3 mA and OZR1 mA variants, these sensors operate at a maximum pressure of 1.

DetailsPDF

DULCOTEST PAA

Reliable sensors

pH range: 1.0 … 9.0 (peracetic acid stability range) · Output signal: 4…20 mA ≈ measuring range, temperature-compensated, uncalibrated, not electrically isolated · Temperature: 1 … 45 °C

The Prominent Sensors DULCOTEST PAA is a membrane-covered amperometric sensor designed for measuring peracetic acid in contaminated water.

DetailsPDF

DULCOTEST PHEF

Reliable sensors

pH-range: 0...12 · Temperature: 0...50 °C · Max. pressure: 7 bar

The Prominent Sensors PHEF 012 SE is a pH combination probe designed for use in aggressive solutions like those containing hydrofluoric acid.

DetailsPDF

DULCOTEST Pt 100/1000

Reliable sensors

Measuring range: 0 – 100 °C · Output signal: 4-20 mA · Electrical connection: SN6

These DULCOTEST temperature sensors are designed for direct measurement or temperature compensation in various water treatment applications.

DetailsPDF

DULCOTEST CGE

Reliable sensors

pH range: 5.5 … 9.5 · Temperature: 5 … 45 °C · Max. pressure: 3.0 bar

The DULCOTEST CGE sensors are designed for the online measurement of total available chlorine, offering high resistance to surfactants and cyanuric acid.

DetailsPDF

DULCOTEST CTE

Reliable sensors

pH range: 5.5 … 9.5 · Temperature range: 5 … 45 °C · Max. pressure: 3.0 bar

The DULCOTEST CTE sensors provide reliable online measurement of total chlorine, including free and combined forms.

DetailsPDF

DULCOTEST RHEK Pt SF

Reliable sensors

Redox voltage (ORP): -1000...+1000 mV · Medium temperature: 0...60 °C · Conductivity: > 150 µS/cm

The DULCOTEST RHEK Pt SF is a redox (ORP) sensor designed for applications such as swimming pools and potable water.

DetailsPDF

Prominent dulco turb c en L.Prominent dulco turb c en L

General

Selection cues: measuring range · accuracy · output signal and process connection

The Prominent dulco turb c en L is an instrument for turbidity measurement.

DetailsPDF

Brand Products & Technical Documents

20 product profiles with integrated document access

Each card keeps the curated model introduction and combines the readable datasheet page, OEM PDF, and official source. Product understanding and document access now share one card set.

Reliable sensors

19 product profiles

Instrumentation & Sensors
ProMinent logo

Product profile

DULCOTEST LF/LFT/LFTK

The DULCOTEST LF/LFT/LFTK is a conductivity sensor for measuring electrolytic conductivity in aqueous media, featuring epoxy resin shafts and special graphite electrodes.

Instrumentation & Sensors
ProMinent logo

Product profile

DULCOTEST PHEI 112 pH

The DULCOTEST PHEI 112 pH sensor is designed for general water applications in industrial and municipal wastewater, cooling water, process water.

Instrumentation & Sensors
ProMinent logo

Product profile

DULCOTEST RHES Pt SE

The DULCOTEST RHES Pt SE is a redox sensor designed for applications such as swimming pool, whirlpool, and drinking water treatment.

Instrumentation & Sensors
ProMinent logo

Product profile

DULCOTEST RHEIC Pt SE

The DULCOTEST RHEIC Pt SE is a potentiometric sensor for measuring ORP in various water applications, including wastewater, cooling water, and process water.

Instrumentation & Sensors
ProMinent logo

Product profile

DULCOTEST BCR

DULCOTEST BCR sensors measure total available bromine from BCDMH and other oxidative disinfectants, as well as total chlorine in contaminated water up to pH 9.5.

Instrumentation & Sensors
ProMinent logo

Product profile

DULCOTEST CDE

The Prominent Sensors DULCOTEST CDE is a standard, membrane-covered amperometric sensor for measuring chlorine dioxide in clear, uncontaminated drinking water.

Show remaining Reliable sensors profiles (13)
Instrumentation & Sensors
ProMinent logo

Product profile

DULCOTEST CLB

The DULCOTEST CLB is a cost-effective amperometric sensor for measuring free chlorine in clear water and electrolysis processes. It operates at a maximum pressure of 3.

Instrumentation & Sensors
ProMinent logo

Product profile

DULCOTEST DO

The Prominent Sensors DULCOTEST DO sensors are designed for measuring dissolved oxygen in water.

Instrumentation & Sensors
ProMinent logo

Product profile

DULCOTEST FLEP 010 0100 SE

The DULCOTEST FLEP 010-SE and FLEP 0100-SE are potentiometric fluoride sensors utilizing a LaF₃ crystal for direct measurement.

Instrumentation & Sensors
ProMinent logo

Product profile

DULCOTEST PER

The DULCOTEST PER is an amperometric sensor for measuring hydrogen peroxide in various water applications, offering precise real-time analysis.

Instrumentation & Sensors
ProMinent logo

Product profile

DULCOTEST PHEE

This Prominent Sensors DULCOTEST PHEE 112 S is a pH combination probe designed for semi-solid or pasty media such as foodstuffs. It features three ceramic diaphragms.

Instrumentation & Sensors
ProMinent logo

Product profile

DULCOTEST RHEN Pt SE

The DULCOTEST RHEN Pt SE is a redox combination probe with a platinum metal electrode and ceramic diaphragm designed for wastewater applications.

Instrumentation & Sensors
ProMinent logo

Product profile

DULCOTEST OZE

The DULCOTEST OZE is a sensor line designed for measuring ozone in water. Available in OZE3 mA and OZR1 mA variants, these sensors operate at a maximum pressure of 1.

Instrumentation & Sensors
ProMinent logo

Product profile

DULCOTEST PAA

The Prominent Sensors DULCOTEST PAA is a membrane-covered amperometric sensor designed for measuring peracetic acid in contaminated water.

Instrumentation & Sensors
ProMinent logo

Product profile

DULCOTEST PHEF

The Prominent Sensors PHEF 012 SE is a pH combination probe designed for use in aggressive solutions like those containing hydrofluoric acid.

Instrumentation & Sensors
ProMinent logo

Product profile

DULCOTEST Pt 100/1000

These DULCOTEST temperature sensors are designed for direct measurement or temperature compensation in various water treatment applications.

Instrumentation & Sensors
ProMinent logo

Product profile

DULCOTEST CGE

The DULCOTEST CGE sensors are designed for the online measurement of total available chlorine, offering high resistance to surfactants and cyanuric acid.

Instrumentation & Sensors
ProMinent logo

Product profile

DULCOTEST CTE

The DULCOTEST CTE sensors provide reliable online measurement of total chlorine, including free and combined forms.

Instrumentation & Sensors
ProMinent logo

Product profile

DULCOTEST RHEK Pt SF

The DULCOTEST RHEK Pt SF is a redox (ORP) sensor designed for applications such as swimming pools and potable water.

General

1 product profile

Instrumentation & Sensors
ProMinent logo

Product profile

Prominent dulco turb c en L.Prominent dulco turb c en L

The Prominent dulco turb c en L is an instrument for turbidity measurement.

Prominent Sensors Instrumentation & Sensors | Models & Datasheets | AquaChain Guide