Back to Water glossary

Water glossary

Chlorine as a Water Disinfectant - Properties, Production, and Applications

Explore chlorine's properties, historical discovery, production methods, and its critical role as a water disinfectant in various applications.

Chlorine: A Comprehensive Guide to its Role in Water Treatment

Chlorine is one of the most widely utilized disinfectants in water treatment due to its broad-spectrum efficacy against most microorganisms and its cost-effectiveness. This guide details its discovery, properties, production, and critical applications in disinfection.

Discovery of Chlorine

Chlorine gas (Cl₂) was first prepared in its pure form by the Swedish chemist Carl Wilhelm Scheele in 1774. He achieved this by heating manganese dioxide (MnO₂) with hydrochloric acid (HCl). The reaction is represented as:

MnO₂ + 4HCl -> MnCl₂ + Cl₂ + 2H₂O

Scheele observed that chlorine gas was water-soluble and possessed bleaching capabilities for various materials. In 1810, Sir Humphry Davy, an English chemist, confirmed chlorine as an element and named it after the Greek word 'chloros', meaning yellow-greenish, describing its characteristic color.

Properties of Chlorine

Chlorine (Cl₂) is a reactive halogen; this group also includes fluorine (F), bromine (Br), iodine (I) and astatine (At). Halogens form many compounds, including metal salts, but not all such salts are water-soluble.

A chlorine atom contains 17 electrons. Its outermost shell has seven electrons, leaving space for one additional electron. This characteristic leads to the formation of either free, charged ions or covalent bonds, completing its outer electron shell.

Chlorine can form both highly stable compounds, such as sodium chloride (NaCl, common salt), and highly reactive ones, like hydrogen chloride (HCl). When hydrogen chloride dissolves in water, it forms hydrochloric acid, which is known for its strong corrosive properties, even capable of corroding stainless steel under concentrated conditions.

Transport and Storage

Given its reactive and corrosive nature, strict safety precautions are essential during the transport, storage, and use of chlorine.

Protect chlorine/hypochlorite solutions from unsuitable light and heat according to the product specification. Photochemical pathways vary; the following equation is an overall decomposition example, not proof that splitting water and releasing atomic oxygen is the sole mechanism:

2HOCl -> 2H⁺ + 2Cl⁻ + O₂

Chlorine Production Methods

Chlorine is primarily produced from chloride compounds through electrolytic or chemical oxidation processes.

Electrolytic Production

Brine electrolysis is a principal industrial method. Chloride ions are oxidized at the anode to chlorine gas, while cathodic products depend on the cell design. Hydrogen gas (H₂) and sodium hydroxide (NaOH) streams require controlled separation, handling and ventilation.

Three main electrolytic methods are employed:

  1. Diaphragm Cell Method: A porous diaphragm separates coated titanium anodes from steel cathodes. Controlled brine flow limits hydroxide back-migration; dissolved salt remains in the caustic stream and requires downstream processing. The diaphragm is not an ion-selective barrier that yields salt-free caustic.

    • Anode reaction (+ pole): 2Cl⁻ -> Cl₂ + 2e⁻
    • Cathode reaction (- pole): 2H₂O + 2e⁻ -> 2OH⁻ + H₂
  2. Mercury Cell Method: This method uses a mercury electrode, yielding purer reaction products. A positive titanium pole and a flowing mercury negative pole are used. At the negative pole, sodium ions (Na⁺) react to form sodium amalgams. These amalgams then react with water in a second reaction vessel to produce sodium hydroxide and hydrogen, keeping the hydrogen gas separate from the chlorine gas formed at the positive pole.

    • Electrolysis cell anode (+ pole): 2Cl⁻ -> Cl₂ + 2e⁻
    • Electrolysis cell cathode (- pole): Na⁺ + e⁻ -> Na
    • Second reaction vessel: 2Na + 2H₂O -> 2Na⁺ + 2OH⁻ + H₂
  3. Membrane Method: Similar to the diaphragm method, but a selective membrane only allows positive ions to pass, resulting in a relatively pure form of sodium hydroxide.

European Production Context: Mercury-cell electrolysis is historical technology subject to phase-out requirements; undated technology shares do not represent current European production. Membrane and diaphragm caustic can require concentration, while 50 mass-% is a product-concentration example, not a universal cell outlet specification.

Chemical Oxidation

Chlorine can also be produced by oxidizing hydrogen chloride with atmospheric oxygen, known as the 'Deacon process', using copper(II) chloride (CuCl₂) as a catalyst:

4HCl + O₂ -> 2H₂O + 2Cl₂

For laboratory-scale production, hydrochloric acid can be oxidized with manganese dioxide:

MnO₂ + 4HCl -> MnCl₂ + 2H₂O + Cl₂

When gaseous chlorine is added to water, a hydrolysis reaction occurs:

Cl₂ + H₂O = H⁺ + Cl⁻ + HOCl

Applications of Chlorine

Chlorine is extensively applied due to its high reactivity, forming compounds with many substances and facilitating bonds between otherwise unreactive substances. When chlorine bonds with carbon-containing substances, organic compounds like plastics, solvents, and oils are formed. It often replaces hydrogen atoms in substitution reactions within molecules.

Medical Science: Chlorine is vital in medicine, used as a disinfectant and a component of many medicines and medical herbs. Chloroform (CHCl₃), a chlorine-containing compound, was an early anesthetic.

Chemical Industry: Tens of thousands of chlorine-containing products exist, including glues, paints, solvents, foam rubbers, car bumpers, food additives, pesticides, and antifreeze. Polyvinyl chloride (PVC) is a widely used chlorine-containing plastic found in drainpipes, insulation, flooring, windows, and bottles.

Industrial Use Distribution: The following undated proportions are illustrative historical figures, not current market statistics:

  • Organic Chemicals (e.g., plastics): Approximately 65% of industrialized chlorine.
  • Bleach and Disinfectants: About 20%.
  • Inorganic Compounds: The remaining portion, used to produce compounds with elements like zinc (Zn), iron (Fe), and titanium (Ti).

Chlorine as a Disinfectant

Chlorine has been used for over two centuries to deactivate pathogenic microorganisms in drinking water, swimming pools, wastewater, household disinfection, and textile bleaching. Its widespread adoption significantly contributed to extending human life expectancy by controlling waterborne diseases.

Chlorine as a Bleach

Bleach typically consists of chlorine gas dissolved in an alkaline solution, such as sodium hydroxide (NaOH). This forms hypochlorite ions (OCl⁻) through an autoredux reaction, creating sodium hypochlorite (NaOCl), an effective and stable disinfectant.

Caution: Bleach must not be combined with acids, as this destabilizes hypochlorite, releasing poisonous chlorine gas.

Bleaching powder is a chlorinated-lime mixture, often represented approximately as CaOCl₂, produced from calcium hydroxide Ca(OH)₂. It is not identical to pure calcium hypochlorite. Its active chlorine forms hypochlorous acid (HOCl) and hypochlorite ions (OCl⁻) in water; use the actual product specification.

Mechanism of Chlorine Disinfection

Chlorine disinfects by reactions with microbial proteins, enzymes, membranes and other susceptible components. Oxidation and chlorination can impair cellular function; the mechanism is not a universal replacement of enzyme hydrogen atoms alone.

When chlorine is added to water, hypochlorous acid (HOCl) forms:

Cl₂ + H₂O -> HOCl + H⁺ + Cl⁻

Depending on the pH, hypochlorous acid partially dissociates into hypochlorite ions (OCl⁻):

HOCl + H₂O -> H₃O⁺ + OCl⁻

One overall hypochlorite decomposition pathway can be represented as:

2OCl⁻ -> 2Cl⁻ + O₂

Free chlorine includes hypochlorous acid (HOCl) and hypochlorite ions (OCl⁻). HOCl generally provides faster microbial inactivation, but the ratio of effectiveness depends on the organism and conditions; there is no universal percentage advantage or need to invoke freely released atomic oxygen.

The neutral hypochlorous acid can more effectively penetrate the negatively charged cell walls and protective layers of pathogenic microorganisms compared to the negatively charged hypochlorite ion, leading to their inactivation or reproductive failure.

pH strongly affects free-chlorine speciation and treatment. Near ambient temperature, pH 7.5 is approximately the equal HOCl/OCl⁻ point; lower pH favors HOCl and higher pH favors OCl⁻. Temperature, target organisms, corrosion and the applicable water-quality requirements must also be considered rather than using a universal optimum pH band.

Free and Bound Active Chlorine

When chlorine is added to water, it first reacts with dissolved organic and inorganic compounds. The amount of chlorine consumed in these initial reactions is termed "chlorine demand." Chlorine that has reacted in this way is no longer available for disinfection.

Chlorine can also react with ammonia (NH₃) to form chloramines, which are compounds containing chlorine, nitrogen, and hydrogen. These are referred to as "bound active chlorine compounds." While they contribute to disinfection, they react much more slowly than "free active chlorine" (hypochlorous acid and hypochlorite ions).

Chlorine Dosing

Chlorine dosing must account for the water's chlorine demand. The dose must be sufficient to ensure a residual amount of chlorine remains for effective disinfection. Chlorine demand is influenced by the organic matter content, pH, contact time, and temperature of the water. Chlorine reactions with organic matter can also produce disinfection byproducts (DBPs), such as trihalomethanes (THMs) and halogenated acetic acids (HAAs).

Dosing Methods:

  • Ordinary Chlorination: Simple addition of chlorine without prior treatment.
  • Pre- and Post-chlorination: Adding chlorine before and after other treatment stages.
  • Rechlorination: Adding chlorine to treated water at various points in the distribution system to maintain disinfection.

Breakpoint Chlorination

Breakpoint chlorination increases dose through combined-chlorine formation and destruction until a free residual can be maintained. Develop the actual-water breakpoint curve and required contact time; a 1 mg/L (1 ppm) example is not a universal disinfection dose, and breakpoint achievement alone does not prove complete pathogen control.

Applied Chlorine Concentrations

Chlorine is transported and stored as a pressurized liquefied gas; pressure depends on temperature and container conditions, not a fixed universal 10 bar value. Applied dose must cover measured demand and validated residual/contact time; 0.2-0.4 mg/L (0.2-0.4 ppm) alone does not guarantee bacterial inactivation in every water.

For large municipal and industrial water treatment plants, chlorine gas is commonly used. Smaller applications often utilize calcium or sodium hypochlorite.

Factors Affecting Chlorine Disinfection Effectiveness

The efficacy of chlorine disinfection is determined by:

  • Chlorine concentrations
  • Contact time
  • Temperature
  • pH
  • Number and types of microorganisms
  • Concentrations of organic matter in the water

Disinfection Time for Fecal Pollutants with Chlorinated Water

The following CDC examples apply to free chlorine at 1 mg/L (1 ppm), pH 7.5 or less and 25 °C (77 °F) or higher, without cyanuric acid. They are not universal treatment-design values; cyanuric acid increases required times:

Pathogen TypeDisinfection Time (1 mg/L Chlorine Residual)
E. coli O157:H7 bacterium< 1 minute
Hepatitis A virus~ 16 minutes
Giardia parasite~ 45 minutes
Cryptosporidium~ 15,300 minutes (10.6 days)

Note: Cryptosporidium is highly resistant to chlorine disinfection.

Health Effects of Chlorine

The human body's response to chlorine exposure depends on the concentration in the air, duration, and frequency of exposure, as well as individual health and environmental conditions. Short-term inhalation of small amounts can cause respiratory issues like coughing, chest pains, and fluid accumulation in the lungs. Skin and eye irritations are also possible.

Chlorine gas is acutely toxic, with effects depending on concentration and exposure. It is heavier than air and was used as a chemical weapon during World War I. Contact with moist eyes and respiratory tissues produces damaging reactive chemistry; injury is not explained by dissolving mucosa to enter blood. Severe inhalation can cause pulmonary edema.

Legislation and Standards for Chlorine in Water

European Union (EU)

Directive 98/83/EC is a historical reference. Apply Directive (EU) 2020/2184 and the relevant national rules, including microbial safety, residual control and byproduct requirements; absence of a single EU free-chlorine parameter does not mean unrestricted dosing.

World Health Organization (WHO)

The cited WHO chemical fact sheet gives a health-based guideline value of 5 mg/L (5 ppm) for free chlorine, not a target dose or a universally binding legal maximum. The operational example of at least 0.5 mg/L (0.5 ppm) after 30 minutes at pH 8 or less must be interpreted with actual demand, temperature, organism and treatment requirements.

United States of America (USA)

The national drinking water standards set a maximum residual chlorine level of 4 mg/L (4 ppm). While chlorine remains the primary disinfectant due to its cost-effectiveness, the use of chlorine gas in wastewater treatment has decreased. This shift is largely due to concerns over disinfection byproducts (e.g., THMs) and the regulatory burden associated with managing toxic chemicals under the Clean Air Act (CAA) Risk Management Plan (RMP) by the EPA. Consequently, many wastewater treatment plants have transitioned from chlorine gas to sodium hypochlorite.

AquaChain Engineering Tip

Monitor pH, actual free residual and effective contact time together, using the applicable organism-specific requirements. A lower pH may increase the HOCl fraction, but adjust it only within material, corrosion and end-use limits; pH control alone does not prove safe disinfection.

For more information on water disinfection, refer to our guide on Drinking Water Preparation.

Frequently Asked Questions

Q1: What is the primary difference between hypochlorous acid (HOCl) and hypochlorite ions (OCl⁻) in disinfection?

A1: HOCl is electrically neutral and generally disinfects faster than negatively charged OCl⁻. Its relative effectiveness depends on the organism and exposure conditions; do not apply a fixed universal percentage advantage.

Q2: Why is breakpoint chlorination used in water treatment?

A2: Breakpoint chlorination can satisfy the actual water demand and reduce combined chlorine sufficiently to maintain a measurable free residual. Confirm ammonia, dose, byproducts and validated contact time; breakpoint alone does not guarantee effective disinfection.

Q3: What are the main concerns regarding disinfection byproducts (DBPs) when using chlorine?

A3: The main concern with DBPs is the formation of compounds like trihalomethanes (THMs) and halogenated acetic acids (HAAs) when chlorine reacts with organic matter in the water. These DBPs can have potential health risks, leading to regulations and efforts to minimize their formation or shift towards alternative disinfectants in certain applications.

References