Tech Library

Calculators & unit converters

Choose a tool, enter your values, and get an instant calculation.

Use a decimal dot (for example 1000.5), without commas or grouping separators. Scientific notation such as 1e3 is supported.

Display decimals
Display precision only changes results, never your input. Small nonzero values use scientific notation.

Basic units

Pressure

Convert pressure units using the same reference. Negative values can represent gauge vacuum; absolute pressure cannot be negative.

Formula & conditions

1 bar = 100 kPa = 0.1 MPa. kgf/cm² denotes force per area; mH₂O uses the conventional water column. Unit conversion does not convert gauge to absolute pressure.

Temperature

Switch between °C, °F, and K for process conditions, shipping limits, and client reports without mental math.

Formula & conditions

Base: °C. °F = °C×9/5+32; K = °C+273.15.

Length & area

Convert lengths and surface areas between metric and US customary units for vessel sizes, piping runs, and membrane or filter areas in quotes and field work.

Formula & conditions

Length: 1 m = 3.28084 ft = 39.3701 in. Area: 1 m² = 10.7639 ft².

Hydraulics

Flow rate

Express the same flow as m³/h, US or UK GPM, L/s, or m³/day so you can match pump curves, supplier datasheets, and daily production figures.

Formula & conditions

Base: m³/h. 1 m³/h = 4.40286 US GPM = 3.66615 UK GPM = 0.27778 L/s = 24 m³/d.

Pipe velocity & diameter

Choose the unknown quantity, enter the other two, and calculate pipe velocity, internal diameter or flow. Display precision does not change your inputs.

Formula & conditions

Q in m³/h, D = internal diameter in mm, v in m/s. v = Q ÷ (3600 × π × (D/2000)²). Nominal pipe size is not the internal diameter.

Calculated result: 0.35 m/s

Velocity reference bands

Illustrative bands: 1–2 m/s; 0.5–1 or 2–2.5 m/s; outside 0.5–2.5 m/s. Suitability also depends on water quality, pipe material, pressure loss and surge analysis.

Current: 0.35 m/s

Volume & mass (bulk density)

Convert bulk volume and mass for filter media (e.g. carbon, resin): enter ρ in kg/L, then align m³, L, gallons, or ft³ with kg, lb, or metric tons for purchasing and logistics.

Formula & conditions

Mass = volume × bulk density (ρ in kg/L). Density changes retain your last volume or mass input. Presets are examples; use measured or specified material density.

Presets

Volume

Mass

Water chemistry

Water hardness (full)

Convert between hardness scales used in boilers, softening, and international specs. All units are tied to mmol/L as Ca²⁺ using the constants in the project spec.

Formula & conditions

Base: mmol/L (Ca²⁺). mg/L as CaCO₃ = mmol/L × 100.0869; °dH = mmol/L × 5.6077; °fH = mmol/L × 10.0087; gpg = mmol/L × 5.8469; meq/L = mmol/L × 2.

Concentration matrix

Relate ppm, ppb, mg/L, μg/L, and mass % for solutions. Mass % uses solution density ρ (g/cm³); dilute water-like defaults use ρ = 1.0.

Formula & conditions

ppm (mg/kg) = mg/L ÷ ρ; ppb (μg/kg) = μg/L ÷ ρ. Mass % = mg/L ÷ (ρ × 10,000). At ρ = 1, ppm ≈ mg/L.

Molarity ↔ mass concentration

Convert molarity (mol/L) to mass concentration (g/L, mg/L) using molecular weight—typical for dosing NaOH, HCl, and other reagents.

Formula & conditions

g/L = (mol/L) × molar mass; mg/L = g/L × 1000. Use the actual chemical formula, including hydration water. Purity and solution strength are separate factors.

EC → TDS (estimate)

Estimate total dissolved solids from electrical conductivity using a tunable factor k (typical for natural waters and NaCl-like mixtures).

Formula & conditions

TDS (mg/L) ≈ EC (μS/cm) × k. Default k = 0.67; allowed 0.4–1.

TDS estimation is an approximation based on the selected k-factor; use lab TDS for compliance and design decisions.

k presets:
Estimated TDS: 335.00 mg/L

Testing & water quality

Mesh ↔ micron (ASTM E11)

Map standard sieve mesh numbers to nominal opening size in millimetres and micrometres for media specification (e.g. activated carbon 8×30).

Formula & conditions

Single mesh uses ASTM E11 nominal openings (mm). Range mode reports the span between two mesh openings (e.g. 8 and 30) for typical commercial cuts.

Mode:

Nominal opening

1.70 mm · 1700.00 μm

Micron = mm × 1000.

SDI — silt density index

Field estimate of fouling potential from timed 500 mL filtration intervals. Uses the same time units for T_i and T_f; T_total is the test duration in minutes.

Formula & conditions

SDI = ((1 − T_i/T_f) × 100) / T_total. If (1 − T_i/T_f) > 75%, the test is invalid (ASTM D4189-style plugging rule).

Use consistent units for T_i and T_f (typically seconds). For design decisions, follow ASTM D4189 and site QA.

Must be > 0.

Must be ≥ T_i.

SDI15 = 2.22Below 3 (SDI₁₅ reference)

Compare only matching test durations. SDI₅ and SDI₁₀ are not interchangeable with SDI₁₅ limits; use the selected membrane model requirements.

Alkalinity — species distribution

Split phenolphthalein (P) and total/methyl-orange (M) alkalinity into hydroxide, carbonate, and bicarbonate (as CaCO₃ equivalents) for dosing and scaling insight.

Formula & conditions

P must not exceed M. Results are alkalinity equivalents as CaCO₃, not ion mass concentrations. The model assumes carbonate-system alkalinity dominates; significant borate, phosphate or organic buffers need another analysis.

OH⁻

0.00

mg/L as CaCO₃

CO₃²⁻

0.00

mg/L as CaCO₃

HCO₃⁻

120.00

mg/L as CaCO₃

Alkalinity balance (CaCO₃ equivalents)

  • Exact model:Σ(OH⁻ + CO₃²⁻ + HCO₃⁻) = 120.00 mg/L · M = 120.00 mg/Lmatches M

Share of M (approximate)

100%

OH⁻ 0.0% · CO₃²⁻ 0.0% · HCO₃⁻ 100.0%

More tools

RO permeate flux — GFD

Calculate membrane flux in GFD and L/m²/h from permeate flow and total active membrane area. Compare the result with the selected membrane and operating conditions.

Formula & conditions

L/m²/h = flow × 1000 ÷ active area. GFD uses US gallons and square feet; both outputs are calculated from the same unrounded inputs.

Flux: 16.83 GFD (28.57 L/m²/h reference)