Back to Water glossary

Water glossary

Deionized and Demineralized Water: Production Methods and Purity Measurement

Explore the processes for producing deionized and demineralized water, including distillation, ion exchange, and reverse osmosis. Learn about critical purity measurement techniques and pH considerations for ultrapure water.

Understanding Pure Water: Definitions and Production Methods

Achieving high-purity water is essential across numerous industries, from pharmaceuticals to semiconductor manufacturing. While terms like "distilled," "deionized," and "demineralized" are often used interchangeably, they refer to distinct purification processes and resulting water qualities.

Distilled Water

Distillation is one of the oldest and most recognized methods for water purification. It involves boiling water in a "still" to create vapor, which is then condensed back into liquid form in a cooling unit. This process effectively separates water from non-volatile dissolved contaminants, such as salts, which are left behind in the boiling vessel.

However, distillation has limitations:

  • Volatile Contaminants: If contaminants are volatile (e.g., certain alcohols), they can also vaporize and recondense with the water, reducing purity.
  • Carry-over: Bursting bubbles at the boiling surface can carry small amounts of non-volatile material into the vapor stream.
  • Ionic Purity: Distillation quality depends on the apparatus, carryover and storage; 1.0 MΩ·cm is not a universal maximum. The ideal pure-water resistivity is approximately 18.2 MΩ·cm at 25°C.
  • pH: Pure water is neutral near pH 7.0 at 25°C; atmospheric CO₂ lowers the measured pH. There is no fixed distilled-water pH range independent of exposure and contamination.
  • Re-contamination: Distilled water is highly susceptible to re-contamination if not handled and stored properly.

Deionized Water

Deionization (DI) uses ion exchange resins to remove dissolved ionic salts. Removal is limited by resin capacity, leakage and operating conditions, not guaranteed 100%. It does not by itself establish removal of uncharged organics, bacteria or viruses. Incidental trapping or specialized adsorption is not a validated general microbial barrier; EDI provides electrically driven ion removal.

Another advanced method for producing deionized water is electrodeionization (EDI), which combines ion exchange resins with ion-selective membranes and a direct current to continuously remove ions without chemical regeneration.

Demineralized Water

Demineralization is a broader term encompassing any process used to remove minerals from water. While it can refer to various methods, it is most commonly associated with ion exchange processes.

Ultrapure Water (UPW)

Ultrapure water is highly treated water characterized by extremely high resistivity and minimal organic content. It is a critical component in sensitive industries such as semiconductor manufacturing, pharmaceuticals, and power generation.

Deionization Technologies

Deionization primarily relies on ion exchange, a process where electrically charged dissolved substances (ions) are bound to positively or negatively charged sites on a resin as water passes through a packed column. Different configurations of ion exchange systems are employed to achieve various qualities of deionized water.

Two-Bed Ion Exchange Systems

These systems typically consist of two separate vessels: one containing a cation-exchange resin in the hydrogen (H⁺) form, and the other containing an anion-exchange resin in the hydroxyl (OH⁻) form.

  1. Cation Exchange: The hydrogen-form cation resin exchanges dissolved cations such as Na⁺, Ca²⁺ and Mg²⁺ for H⁺, subject to capacity and leakage.
  2. Anion Exchange: Hydroxide-form anion resin exchanges anions such as Cl⁻, SO₄²⁻ and HCO₃⁻ for OH⁻. Strong-base resin can also remove weakly ionized reactive silica; silica should not be represented only as SiO₃²⁻ at ordinary water pH.
  3. Water Formation: The released hydrogen and hydroxide ions combine to form pure water (H⁺ + OH⁻ → H₂O).

Properly designed systems remove dissolved ions and reactive silica to specified residual limits; colloidal silica is not reliably removed by ion exchange alone. For high CO₂ load, an interstage degasifier can reduce dissolved CO₂ to a few milligrams per liter (mg/L), depending on design, reducing strong-base anion load and regeneration chemicals.

Strong Acid Cation (SAC) + Strong Base Anion (SBA) Systems

This is the simplest two-bed arrangement, capable of producing deionized water suitable for a wide range of applications.

Strong Acid Cation (SAC) + Weak Base Anion (WBA) + Strong Base Anion (SBA) Systems

This variation provides the same high quality of deionized water but offers economic advantages when treating water with high concentrations of strong anions (e.g., chlorides and sulfates). An additional weak base anion exchanger is installed before the final strong base anion exchanger.

  • CO₂ Removal: An optional CO₂ removal unit can be placed either after the cation exchanger or between the two anion exchangers.
  • Regeneration Efficiency: Suitable NaOH regenerant fractions from the strong-base bed can be reused for the weak-base bed, reducing chemical demand. Regeneration design and effluent composition must be controlled; silica-rich initial fractions may need diversion to prevent weak-base resin fouling.
  • Organic Protection: The weak base resin also helps protect the strong base resin from fouling by organic matter present in the raw water.

Mixed-Bed Deionization

In mixed-bed deionizers, cation-exchange and anion-exchange resins are intimately mixed and contained within a single pressure vessel. This configuration creates an "infinite" series of cation and anion exchangers, leading to exceptionally high water purity.

  • Regeneration Process:

    1. Separation: During regeneration, the two resins are hydraulically separated; the lighter anion resin rises to the top, while the heavier cation resin settles at the bottom.
    2. Regeneration: Caustic soda is used to regenerate the anion resin, and a strong acid regenerates the cation resin.
    3. Rinsing: Excess regenerant is removed by rinsing each bed separately.
    4. Remixing: The resins are then remixed by agitation with compressed air.
  • Advantages:

    • Produces very high-purity water with consistent quality throughout the cycle.
    • Achieves an almost neutral pH.
    • Rinse-water demand depends on resin, contamination and regeneration design; it is not universally lower than a two-bed system.
  • Disadvantages:

    • Lower exchange capacity compared to two-bed systems.
    • More complicated operating procedure due to the separation and remixing steps.

Reverse Osmosis (RO)

Beyond ion exchange, reverse osmosis (RO) is another highly effective process for producing deionized water. RO is considered the finest filtration technology available, capable of removing particles as small as individual ions from a solution.

  • Mechanism: RO purifies water by applying pressure to force water molecules through a semi-permeable membrane, leaving behind salts and other impurities. This process improves the color, taste, and overall properties of the fluid.
  • Rejection Capabilities: RO can reduce salts, sugars, proteins, particles, dyes, microbes and pyrogens under suitable conditions. A generic 150-250 Daltons range is not a universal molecular-weight cutoff, and >99.9% microbial/pyrogen rejection cannot be assumed without challenge validation and demonstrated membrane/system integrity.
  • System Configurations: Single-pass RO can meet selected water-quality targets. Double-pass RO improves ionic purity, but ultrapure-water production commonly also requires EDI or ion-exchange polishing, microbial control and appropriate storage/distribution.
  • Operating Pressure: The driving force for RO purification is pressure, typically ranging from 3.4 to 69 bar (50 to 1000 psig).
  • Efficiency: RO often uses less energy than phase-change purification and can reduce downstream ion-exchange regeneration load. Overall energy and chemical demand depend on feed quality, recovery, cleaning and the complete treatment train.
  • Ion Separation: The separation of ions by RO is aided by their electrical charge. Dissolved ions, such as salts, are more likely to be rejected by the membrane than uncharged substances like many organics. Generally, the larger the charge and the larger the particle, the higher the rejection rate.

Reverse Osmosis

Measuring Water Purity

Water purity can be assessed using various analytical methods, each providing different insights into contaminant levels.

General Purity Indicators

  • Weight of Dissolved Material: This involves determining the mass of dissolved solids (solutes) in a given volume of water.
  • Colligative Properties: Impurities affect the physical properties of water, such as increasing its boiling point or lowering its freezing point.
  • Refractive Index: The refractive index, which measures how transparent materials bend light waves, is also influenced by the presence of solutes.

Electrical Conductivity or Resistivity

One of the quickest and most common methods to estimate water purity is by measuring its electrical conductivity or resistance. Very pure water conducts electricity poorly, meaning it has high electrical resistance (or low conductivity). This method is highly sensitive to the presence of dissolved ions.

pH Value

Pure water is neutral near pH 7.0 at 25°C, not acidic by definition. Its neutral pH changes with temperature. Fresh high-purity water rapidly absorbs atmospheric CO₂, lowering pH through carbonic-acid equilibria:

CO₂ + H₂O ⇌ H₂CO₃ (carbonic acid); H₂CO₃ + H₂O ⇌ H₃O⁺ (hydronium ion) + HCO₃⁻ (bicarbonate ion)

Air exposure can produce a pH near 5.8 in example conditions; the final value and time depend on CO₂ partial pressure, temperature and contamination, not a fixed property of distilled water.

Challenges in Measuring Ultrapure Water pH

Measuring the pH of ultrapure water presents unique challenges:

  • Rapid Contamination: High-purity water quickly absorbs atmospheric CO₂ and other contaminants, changing pH and increasing conductivity. A small CO₂ concentration does not justify a universal pH 4.5 claim or unchanged ionic purity.
  • Low Conductivity: The extremely low conductivity of ultrapure water can interfere with the accuracy of standard pH meters, making reliable measurements difficult.

High resistivity near 18.2 MΩ·cm at 25°C supports low ionic contamination and near-neutral pH under ultrapure-water conditions. A value of 10.0 MΩ·cm may correspond roughly to pH 6.6-7.6 in a simple acid/base model, but resistivity alone does not uniquely determine pH in a general sample and cannot establish microbial or organic purity.

Illustrative pH Values of Common Substances (Composition-Dependent)

SubstancepH Range
Battery Acid1.0
Stomach Acid1.0-2.0
Soft Drinks2.0-4.0
Wines2.3-3.8
Cola2.5
Coffee4.85-5.13 (study examples; preparation-dependent)
Orange Juice3.5
Beer4.0-5.0
Distilled Water5.8
Milk6.5

A slightly acidic pH after air exposure does not establish systemic acidification, but neither pH nor the deionized/distilled label proves drinking-water safety. Industrial or laboratory water should not be consumed unless its chemical and microbial quality, contact materials and storage satisfy applicable potable-water requirements.

AquaChain Engineering Tip

For ion exchange systems, effective pre-treatment (e.g., multi-media filtration, activated carbon filtration, or ultrafiltration) is crucial to protect resins from fouling by suspended solids, organics, and chlorine. Implementing robust pre-treatment extends resin life, reduces regeneration frequency, and maintains consistent high-quality water production.

Frequently Asked Questions

Q1: What is the primary difference between deionized and demineralized water? A1: Deionized water specifically refers to water treated by ion exchange to remove ionized salts. Demineralized water is a broader term for any process that removes minerals, often also referring to ion exchange but can include other methods like reverse osmosis.

Q2: Why is the pH of ultrapure water difficult to measure accurately? A2: Ultrapure water rapidly absorbs atmospheric carbon dioxide, forming carbonic acid and lowering its pH. Additionally, its very low conductivity can interfere with the accuracy of standard pH meters, making reliable measurements challenging.

Q3: Is drinking deionized water harmful to human health? A3: Deionization alone does not establish drinking-water safety. Use water produced and controlled for potable use, with appropriate chemical and microbial quality and safe contact materials/storage; do not drink laboratory or industrial process water merely because its conductivity is low.