Back to RO Membranes
3M logo

International brand dossier

3M-Liqui-Cel® Membrane Contactors

3M Liqui-Cel and Liqui-Flux records should be read as 3M membrane contactor and membrane-filtration technologies.Liqui-Cel is used for dissolved gas control such as degassing and carbonation management, while Liqui-Flux UF modules support filtration duties where compact membrane modules and established 3M component supply are useful.

3M-Liqui-Cel® Membrane Contactors's position in RO/NF membranes and related equipment is defined by product families such as Debubbling, Gas transfer, Degassing (low surface tension fluids) and Application / guidance.

The portfolio is best understood inside brackish water, seawater desalination, ultrapure water, process separation, reuse, degassing, and membrane system packaging, where engineers compare the technology route, family boundaries, and duty fit before narrowing to individual models.Representative series on this page include MM Series 0.5 x 1, MM Series 0.75 x 1 and MM Series 1.7 x 5.5.Engineers should compare element size, salt rejection, permeate flow, pressure rating, fouling resistance, connection type, and vessel fit.

30

Indexed models

4

Product families

0

Subgroups

Model index

Product range and selection

How to choose 3M-Liqui-Cel® Contactors Closed Circuit Reverse Osmosis

This section answers two questions: which main product families 3M-Liqui-Cel® Contactors offers, and which parameters to compare before choosing a specific model.

Step 1: Choose a product family by application

The main families shown on this page are Debubbling, Gas transfer, Degassing (low surface tension fluids), and Application / guidance. Start with the treatment objective, equipment format, and operating duty, then use the model index below to compare exact specifications.

Step 2: Confirm the model by key parameters

After choosing a product family, compare feed salinity, target salt rejection, permeate flow, operating pressure, fouling tendency, and element size and connection. Replacement projects should also verify installation or loading conditions, interfaces, and compatibility with the existing system; new projects should consider operating practice, maintenance, and spare-parts or consumables availability.

Product family overview

4 product familys on this page.

Debubbling

5 models in this family. Representative models: MM Series 0.5 x 1, MM Series 0.75 x 1, MM Series 1.7 x 5.5.

Gas transfer

13 models in this family. Representative models: EXF Series 2.5 x 8, EXF Series 4 x 13, EXF Series 4 x 28.

Degassing (low surface tension fluids)

6 models in this family. Representative models: SP Series 0.5 x 1, SP Series 1 x 3, SP Series 2 x 6.

Application / guidance

6 models in this family. Representative models: 3M Liqui-Cel General brochure, 3M liqui-Cel Inlet & sweep gas guideline, 3M Liqui-Cel cleaning & storage.

Quick Model Index

Fast lookup for 30 indexed products

Search models, families, applications, or parameters; compare 2–4 candidates, save or export the shortlist, and open it on another device by link or QR code.

Products & documents

Showing 30 of 30 models

Select 2–4 models to compare. Your shortlist is saved on this device and can travel by link or QR code.

Ask with selected models

MM Series 0.5 x 1

Debubbling

Liquid Flow Guidelines: 5 – 30 ml/min (Liquid must flow on the shellside) · Weight (approximate) - Dry: 10 grams · Membrane/Potting Material: Polypropylene / Epoxy

The 3M™ Liqui-Cel™ MM-0.5x1 Series is a membrane contactor designed for gas transfer applications.

DetailsPDF

MM Series 0.75 x 1

Debubbling

Liquid Flow Guidelines: 15 - 200 ml/min · Maximum Shellside LIQUID Working Temperature/Pressure: 5-25°C, 3.1 barg (41-77°F, 45 psig) · Membrane/Potting Material: Polypropylene / Epoxy

This 3M™ Liqui-Cel™ MM-0.75x1 Series Membrane Contactor features a no baffle disc design with X40 fiber membrane material.

DetailsPDF

MM Series 1.7 x 5.5

Debubbling

Liquid Flow Guidelines: <2500 ml/min · Nominal diameter: 43 mm (1.7 in) · Nominal length: 182 mm (7.2 in) or 114 mm (4.5 in) – See the official PDF for exact dimensions and specific orientations

The 3M™ Liqui-Cel™ MM-1.7x5.5 Series Membrane Contactor is designed for gas or vacuum transfer applications with a polycarbonate housing.

DetailsPDF

MM Series 1.7 x 8.75

Debubbling

Weight (approximate): 186 grams (dry) · Membrane/Potting Material: Polypropylene/Polyurethane · Housing Material: Polycarbonate

The 3M™ Liqui-Cel™ MM-1.7x8.75 Series is a membrane contactor designed for degassing liquids. It features a parallel flow.

DetailsPDF

MM Series 1.7 x 10

Debubbling

Liquid Flow Guidelines: <2000 ml/min · Maximum Lumenside LIQUID Working Temperature/Pressure: 5-20°C, 8 barg · Maximum Applied Shellside Gas Temperature/Pressure: 20°C, 6 barg

The 3M™ Liqui-Cel™ MM-1.7x10 Series Membrane Contactor is designed for gasification and degassing applications.

DetailsPDF

EXF Series 2.5 x 8

Gas transfer

Maximum Applied Gas Pressure: 4.8 barg at 25°C (70 psig at 77°F) (This is for integrity testing; normal operating pressures are typically lower.) · Overall length: 254 mm (10.0 in) or 277 mm (10.9 in) depending on orientation · Diameter: 67 mm (2.6 in) to 77 mm (3.1 in)

The 3M-Liqui-Cel EXF-2.5x8 is a membrane contactor designed for gas removal from liquids.

DetailsPDF

EXF Series 4 x 13

Gas transfer

Liquid Flow Guidelines: 0.5–3.4 m³/hr (2–15 gpm) · Overall length: 512 mm (20.1 in) · Diameter: 116 mm (4.6 in)

The 3M™ Liqui-Cel™ EXF-4x13 is an Extra-Flow membrane contactor designed for gas transfer applications in water treatment.

DetailsPDF

EXF Series 4 x 28

Gas transfer

Liquid Flow Guidelines: 0.9 – 6.8 m³/hr (4 – 30 gpm) · Overall Length: 889 mm (35.0 in) · Diameter (main): 116 mm (4.6 in)

The 3M™ Liqui-Cel™ EXF-4x28 is an Extra-Flow membrane contactor designed for gas transfer applications.

DetailsPDF

EXF Series 6 x 28

Gas transfer

Liquid Flow Guidelines: 1 – 11 m³/hr (5 – 50 gpm) · Maximum Applied Gas Pressure: 4.1 barg at 25°C (60 psig at 77°F) · Membrane/Potting Material: Polypropylene/Epoxy

The 3M™ Liqui-Cel™ EXF-6x28 Series is a membrane contactor available with X50 fiber for CO₂ removal or X40 fiber for O₂ removal.

DetailsPDF

EXF Series 8 x 20

Gas transfer

Liquid Flow Guidelines: 1 – 11 m³/hr (5 – 50 gpm) · Maximum Applied Gas Pressure: 5.2 barg at 25°C (75 psig at 77°F) · Housing Material: 316L SS Housing, ABS Cartridge Shell

The 3M™ Liqui-Cel™ EXF-8x20 Series is a membrane contactor recommended for gas transfer applications, including oxygen and carbon dioxide removal.

DetailsPDF

EXF Series 8 x 20 Stainless steel housing

Gas transfer

Liquid Flow Guidelines: 1 – 11 m³/hr (5 – 50 gpm) · Maximum Applied Gas Pressure: 2.1 barg at 25°C (30 psig at 77°F) (for integrity testing at ambient temperatures; normal operating pressures are typically lower) · Pressure Guideline: Liquid pressure should always exceed gas pressure

The 3M™ Liqui-Cel™ EXF-8x20 is an industrial series membrane contactor designed for CO₂ removal and other gas transfer applications.

DetailsPDF

EXF Series 8 x 40

Gas transfer

Liquid Flow Rate: 7 – 28 m³/hr (30 – 125 gpm) · Maximum Applied Gas Pressure: 2.1 barg at 25°C (30 psig at 77°F) · Length: 1502 mm (59.2 in)

The 3M™ Liqui-Cel™ EXF-8x40 Series is an extra-flow membrane contactor with a center baffle, designed for high-pressure O₂ removal.

DetailsPDF

EXF Series 8 x 80

Gas transfer

Liquid Flow Guidelines: 7 – 28 m³/hr (30 – 125 gpm) · Maximum Applied Gas Pressure: 2.1 barg at 25°C (30 psig at 77°F) (for integrity testing at ambient temperatures; normal operating pressures are typically lower) · Overall Length: 2518 mm (99.2 in)

The 3M Liqui-Cel EXF-8x80 Series is a membrane contactor designed for high-pressure gas transfer applications like O₂ removal.

DetailsPDF

EXF Series 8 x 40/8 x 80 cartridge

Gas transfer

Weight (Dry, approximate): 11 kg (25 lbs) · Cartridge Shell and Center Tube Material: ABS · End Cap Adapter and Inner Connector Material: ABS

The EXF Series 8 x 40/8 x 80 cartridge is a membrane contactor designed for high-pressure oxygen removal and other gas transfer applications.

DetailsPDF

EXF Series 10 x 28

Gas transfer

Liquid Flow Guidelines: 10 – 57 m³/hr (44 – 250 gpm) · Pressure Limits Basis: Pressures are based on fluid group 2 (other) liquids and gases per the European Union Pressure Equipment Directive 2014/68/EU · Membrane/Potting Material: Polypropylene / Epoxy

The 3M-Liqui-Cel® EXF-10x28 Series Membrane Contactor is designed for gas transfer applications like CO₂ or O₂ removal from liquids.

DetailsPDF

EXF Series 10 x 28

Gas transfer

Liquid Flow Guidelines: 10 – 48 m³/hr (44 – 210 gpm) · Maximum Shellside LIQUID Working Temperature/Pressure: 5-50°C, 4.1 barg (41-122°F, 60 psig) · Maximum Applied Gas Pressure: 4.1 barg at 25°C (60 psig at 77°F)

The 3M™ Liqui-Cel™ EXF-10x28 is an industrial series membrane contactor designed for liquid degassing applications.

DetailsPDF

EXF Series 14 x 28

Gas transfer

Liquid Flow Guidelines: 16 – 91 m³/hr (70 – 400 gpm) · Maximum Applied Gas Pressure: 4.1 barg at 25°C (60 psig at 77°F) · Overall length (with Nylon End Caps): 1156 mm (45.5 in)

The 3M Liqui-Cel EXF-14x28 Series Membrane Contactor is designed for gas transfer applications, featuring an Extra-Flow with Center Baffle cartridge.

DetailsPDF

EXF Series 14 x 40

Gas transfer

Liquid Flow Guidelines: 16 – 125 m³/hr (70 – 550 gpm) · Maximum Applied Gas Pressure: 4.1 barg at 25°C (60 psig at 77°F) · Overall length with engineered thermoplastic end caps: 1466 mm (57.7 in)

The 3M™ Liqui-Cel™ EXF-14x40 Series is a membrane contactor designed for O₂ removal and other gas transfer applications.

DetailsPDF

SP Series 0.5 x 1

Degassing (low surface tension fluids)

Liquid Flow Guidelines: 5 – 30 ml/min (Liquid must flow on the shellside) · Membrane/Potting Material: Polyolefin / Epoxy · Material: Black Polyethylene

The 3M-Liqui-Cel SP-0.5x1 Series is a membrane contactor designed for gas transfer applications.

DetailsPDF

SP Series 1 x 3

Degassing (low surface tension fluids)

Liquid Flow Guidelines: 15 - 60 ml/min (Liquid must flow on the shellside) · Typical Membrane Surface Area: 294 cm² · Membrane/Potting Material: Polyolefin / Polyethylene

The SP Series 1x3 is a membrane contactor designed for degasification of low surface tension liquids.

DetailsPDF

SP Series 2 x 6

Degassing (low surface tension fluids)

Liquid Flow Guidelines: 100 ml/min – 1 liter/min (Liquid must flow on the shellside) · Overall Length: 143 mm (5.6 in) · Diameter: 56 mm (2.2 in)

The 3M™ Liqui-Cel™ SP-2x6 Series is a membrane contactor for gas/liquid contacting applications. It features a no baffle radial flow cartridge configuration.

DetailsPDF

SP Series 2.5 x 8

Degassing (low surface tension fluids)

Liquid Flow Guidelines (Shellside): 0.1 – 0.7 m³/hr (0.5 – 3 gpm) · Oxygen Removal % vs. Water Flow Rate: Shows the percentage of oxygen removal relative to water flow rate (in m³/hr and gpm) at different vacuum levels (50 torr, 75 torr) · Maximum Applied Gas Pressure: 4.1 barg at 25°C (60 psig at 77°F)

The 3M™ Liqui-Cel™ SP-2.5x8 Series is a membrane contactor designed for liquid degassing and gas transfer applications.

DetailsPDF

SP Series 4 x 13

Degassing (low surface tension fluids)

Liquid Flow Guidelines: 0.2 – 3.4 m³/hr (1–15 gpm) · Maximum Applied Gas Pressure: 4.1 barg at 25°C (60 psig at 77°F) · Nominal Dimensions (Polypropylene housing): 116 mm (4.6 in), 85 mm (3.3 in), 413.6 mm (16.3 in). See full housing drawing on 3M.com/Liqui-Cel for additional details

The SP Series 4x13 is an Extra-Flow membrane contactor with a center baffle, constructed with a polypropylene housing and polyolefin membrane.

DetailsPDF

SP Series 4 x 28

Degassing (low surface tension fluids)

Liquid Flow Guidelines: 1.1-6.8 m³/hr (5-30 gpm) · Maximum Applied Gas Pressure: 4.1 barg at 25°C (60 psig at 77°F) · Material: Polypropylene, 316L SS (32 Ra finish)

The 3M-Liqui-Cel SP Series 4x28 is a membrane contactor designed for degassing and gas transfer applications, available with fluoroelastomer or perfluoroelastomer seals.

DetailsPDF

3M Liqui-Cel General brochure

Application / guidance

Transverse flow: Liquid flows into the liquid inlet, crosses the hollow fibers, and then exits through the opposite port. No baffle is used. A vacuum or strip gas can be applied to either gas port · Radial flow: A plugged center tube on one side forces liquid radially over the hollow fibers. Primarily used for degassing low surface tension fluids · Extra-flow in high pressure vessel: An RO-style vessel generates a much higher maximum pressure. Liquid is directed radially across the membrane array by a baffle

3M™ Liqui-Cel™ Membrane Contactors are gas transfer devices that use microporous hollow fiber membranes to remove, add, or control dissolved gases in liquids.

DetailsPDF

3M liqui-Cel Inlet & sweep gas guideline

Application / guidance

Selection cues: rejection · permeate flow · membrane area and operating pressure

This document provides guidelines for inlet water and sweep gas quality for 3M™ Liqui-Cel™ Membrane Contactors.

DetailsPDF

3M Liqui-Cel cleaning & storage

Application / guidance

Water pressure: Max 2 bar (29 psi) · Water temperature: Max 85°C (185°F) · Chlorine: 100 ppm for 15 min (Once/month). Use Hypochlorite at high pH only; avoid Chlorine Dioxide

These 3M Liqui-Cel EXF Series membrane contactors are designed for removing or adding dissolved gases and bubbles to compatible liquids in industrial and food and...

DetailsPDF

3M Liqui-Cel operating manual

Application / guidance

Cleaning Pressure Differential: For 2.5x8-inch, 4-inch, and 10-inch membrane contactors, lumen side pressure should never exceed shell side pressure during cleaning · High Pressure: Similar to Extra-Flow but with a different housing concept for high-pressure applications (e.g., 8 x 40 and 8 x 80-inch contactors) · Power Supply: Always use a grounded power supply of the appropriate voltage matching the system’s vacuum pump or blower voltage, with 15 amp fuse protection and a local disconnect switch

The 3M™ Liqui-Cel™ Extra-Flow Membrane Contactors are designed to add or remove dissolved gases from liquid streams using microporous polypropylene hollow fibers.

DetailsPDF

3M Liqui-Cel membrane contactor power plant thailand

Application / guidance

Membrane Pore Size: 0.03 µm · Pressure: 1.6 bar min · pH: 6.5-8

This 3M Liqui-Cel membrane contactor is designed for CO₂ removal in power plant applications, operating downstream of a double-pass RO system.

DetailsPDF

3M Liqui Cel inlet water &amp; sweep gas guideline L

Application / guidance

Silt Density Index: <3 · Turbidity (NTU): <0.5

This product provides guidelines for inlet water and sweep gas conditions for 3M™ Liqui-Cel™ Membrane Contactors. Recommended pre-treatment includes softening.

DetailsPDF

Brand Products & Technical Documents

30 product profiles with integrated document access

Each card keeps the curated model introduction and combines the readable datasheet page, OEM PDF, and official source. Product understanding and document access now share one card set.

Debubbling

5 product profiles

Closed Circuit Reverse Osmosis
3M logo

Product profile

MM Series 0.5 x 1

The 3M™ Liqui-Cel™ MM-0.5x1 Series is a membrane contactor designed for gas transfer applications.

Closed Circuit Reverse Osmosis
3M logo

Product profile

MM Series 0.75 x 1

This 3M™ Liqui-Cel™ MM-0.75x1 Series Membrane Contactor features a no baffle disc design with X40 fiber membrane material.

Closed Circuit Reverse Osmosis
3M logo

Product profile

MM Series 1.7 x 5.5

The 3M™ Liqui-Cel™ MM-1.7x5.5 Series Membrane Contactor is designed for gas or vacuum transfer applications with a polycarbonate housing.

Closed Circuit Reverse Osmosis
3M logo

Product profile

MM Series 1.7 x 8.75

The 3M™ Liqui-Cel™ MM-1.7x8.75 Series is a membrane contactor designed for degassing liquids. It features a parallel flow.

Closed Circuit Reverse Osmosis
3M logo

Product profile

MM Series 1.7 x 10

The 3M™ Liqui-Cel™ MM-1.7x10 Series Membrane Contactor is designed for gasification and degassing applications.

Gas transfer

13 product profiles

Closed Circuit Reverse Osmosis
3M logo

Product profile

EXF Series 2.5 x 8

The 3M-Liqui-Cel EXF-2.5x8 is a membrane contactor designed for gas removal from liquids.

Closed Circuit Reverse Osmosis
3M logo

Product profile

EXF Series 4 x 13

The 3M™ Liqui-Cel™ EXF-4x13 is an Extra-Flow membrane contactor designed for gas transfer applications in water treatment.

Closed Circuit Reverse Osmosis
3M logo

Product profile

EXF Series 4 x 28

The 3M™ Liqui-Cel™ EXF-4x28 is an Extra-Flow membrane contactor designed for gas transfer applications.

Closed Circuit Reverse Osmosis
3M logo

Product profile

EXF Series 6 x 28

The 3M™ Liqui-Cel™ EXF-6x28 Series is a membrane contactor available with X50 fiber for CO₂ removal or X40 fiber for O₂ removal.

Closed Circuit Reverse Osmosis
3M logo

Product profile

EXF Series 8 x 20

The 3M™ Liqui-Cel™ EXF-8x20 Series is a membrane contactor recommended for gas transfer applications, including oxygen and carbon dioxide removal.

Closed Circuit Reverse Osmosis
3M logo

Product profile

EXF Series 8 x 20 Stainless steel housing

The 3M™ Liqui-Cel™ EXF-8x20 is an industrial series membrane contactor designed for CO₂ removal and other gas transfer applications.

Show remaining Gas transfer profiles (7)
Closed Circuit Reverse Osmosis
3M logo

Product profile

EXF Series 8 x 40

The 3M™ Liqui-Cel™ EXF-8x40 Series is an extra-flow membrane contactor with a center baffle, designed for high-pressure O₂ removal.

Closed Circuit Reverse Osmosis
3M logo

Product profile

EXF Series 8 x 80

The 3M Liqui-Cel EXF-8x80 Series is a membrane contactor designed for high-pressure gas transfer applications like O₂ removal.

Closed Circuit Reverse Osmosis
3M logo

Product profile

EXF Series 8 x 40/8 x 80 cartridge

The EXF Series 8 x 40/8 x 80 cartridge is a membrane contactor designed for high-pressure oxygen removal and other gas transfer applications.

Closed Circuit Reverse Osmosis
3M logo

Product profile

EXF Series 10 x 28

The 3M-Liqui-Cel® EXF-10x28 Series Membrane Contactor is designed for gas transfer applications like CO₂ or O₂ removal from liquids.

Closed Circuit Reverse Osmosis
3M logo

Product profile

EXF Series 10 x 28

The 3M™ Liqui-Cel™ EXF-10x28 is an industrial series membrane contactor designed for liquid degassing applications.

Closed Circuit Reverse Osmosis
3M logo

Product profile

EXF Series 14 x 28

The 3M Liqui-Cel EXF-14x28 Series Membrane Contactor is designed for gas transfer applications, featuring an Extra-Flow with Center Baffle cartridge.

Closed Circuit Reverse Osmosis
3M logo

Product profile

EXF Series 14 x 40

The 3M™ Liqui-Cel™ EXF-14x40 Series is a membrane contactor designed for O₂ removal and other gas transfer applications.

Degassing (low surface tension fluids)

6 product profiles

Closed Circuit Reverse Osmosis
3M logo

Product profile

SP Series 0.5 x 1

The 3M-Liqui-Cel SP-0.5x1 Series is a membrane contactor designed for gas transfer applications.

Closed Circuit Reverse Osmosis
3M logo

Product profile

SP Series 1 x 3

The SP Series 1x3 is a membrane contactor designed for degasification of low surface tension liquids.

Closed Circuit Reverse Osmosis
3M logo

Product profile

SP Series 2 x 6

The 3M™ Liqui-Cel™ SP-2x6 Series is a membrane contactor for gas/liquid contacting applications. It features a no baffle radial flow cartridge configuration.

Closed Circuit Reverse Osmosis
3M logo

Product profile

SP Series 2.5 x 8

The 3M™ Liqui-Cel™ SP-2.5x8 Series is a membrane contactor designed for liquid degassing and gas transfer applications.

Closed Circuit Reverse Osmosis
3M logo

Product profile

SP Series 4 x 13

The SP Series 4x13 is an Extra-Flow membrane contactor with a center baffle, constructed with a polypropylene housing and polyolefin membrane.

Closed Circuit Reverse Osmosis
3M logo

Product profile

SP Series 4 x 28

The 3M-Liqui-Cel SP Series 4x28 is a membrane contactor designed for degassing and gas transfer applications, available with fluoroelastomer or perfluoroelastomer seals.

Application / guidance

6 product profiles

Closed Circuit Reverse Osmosis
3M logo

Product profile

3M Liqui-Cel General brochure

3M™ Liqui-Cel™ Membrane Contactors are gas transfer devices that use microporous hollow fiber membranes to remove, add, or control dissolved gases in liquids.

Closed Circuit Reverse Osmosis
3M logo

Product profile

3M liqui-Cel Inlet & sweep gas guideline

This document provides guidelines for inlet water and sweep gas quality for 3M™ Liqui-Cel™ Membrane Contactors.

Closed Circuit Reverse Osmosis
3M logo

Product profile

3M Liqui-Cel cleaning & storage

These 3M Liqui-Cel EXF Series membrane contactors are designed for removing or adding dissolved gases and bubbles to compatible liquids in industrial and food and...

Closed Circuit Reverse Osmosis
3M logo

Product profile

3M Liqui-Cel operating manual

The 3M™ Liqui-Cel™ Extra-Flow Membrane Contactors are designed to add or remove dissolved gases from liquid streams using microporous polypropylene hollow fibers.

Closed Circuit Reverse Osmosis
3M logo

Product profile

3M Liqui-Cel membrane contactor power plant thailand

This 3M Liqui-Cel membrane contactor is designed for CO₂ removal in power plant applications, operating downstream of a double-pass RO system.

Closed Circuit Reverse Osmosis
3M logo

Product profile

3M Liqui Cel inlet water &amp; sweep gas guideline L

This product provides guidelines for inlet water and sweep gas conditions for 3M™ Liqui-Cel™ Membrane Contactors. Recommended pre-treatment includes softening.

3M-Liqui-Cel® Membrane Contactors RO Membranes | Models & Datasheets | AquaChain Guide