Tóm tắt tài liệu kỹ thuật
IMT 225 UF-MB-TAP
PDF datasheet mirror for IMT 225 UF-MB-TAP (IMT Ultrafiltration). Verify with OEM before design.
Summary
Product identification
The product is an Ultrafiltration element, model 225 UF/MB/TAP.
Mechanical / hydraulic
Element data
- Material housing: PVC
- Material connector: PVC
- Housing length: 250 mm (10 inch) ± 2.0
- Element length: 376 mm (15 inch) ± 3.0
- Element length (without screw ends): 328 mm (13 inch) ± 3.0
- Distance permeate connector-feed connector: 142 mm (6 inch) ± 2.0
- Distance permeate connector-feed connector (without screw ends): 118 mm (5 inch) ± 2.0
- Distance permeate connector-element center: 55 mm (121 inch) ± 2.0
- Permeate connection male OD: 1/2"
- Feed connection male OD: 1/2"
- Housing OD: 50 mm (2 inch)
- Element OD: 50 mm (2 inch)
- Endcaps ID (without screw ends): 25 mm (1 inch)
- Weight: 0.4 kg (1 lbs)
Membrane data
- Material: PES
- Type: SevenBore®
- Diameter bores ID: 0.9 mm (0.04 inch)
- Diameter fiber OD: 4.0 mm (0.16 inch)
- MWCO: 100-150 kD
- Area: 0.25 m² (3 ft²)
Operating limits
Typical process conditions
- Maximum operating temperature: 40 °C (104 °F)
- Maximum system pressure: 10 bar (145 psi)
- Transmembrane pressure:
- Operation: < 1.0 bar (< 14.5 psi)
- Maximum: 2.5 bar (36 psi)
- Productivity:
- Clean water at 25 °C (77 °F): 1300-1600 l/m²barh (53-65 gfd/psi)
- Process: 100 to 350 l/m²h (60 to 210 gfd)
- Backwash/forward flush: 250 l/m²h (150 gfd)
- Permeate flow at 100 l/m²h: 25 l/h (0.11 gpm)
- pH range during operation: 3-10
Cleaning
- Soaking time during cleaning: min 5 min
- pH range during cleaning: 1-13
- Disinfecting chemicals:
- Hypochlorite (NaOCl): 50-200 ppm
- Hydrogen peroxide (H₂O₂): 100-200 ppm
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the official OEM PDF datasheet. Contractual data must always match the specific OEM PDF revision used for the project.