Back to Water glossary

Water glossary

WHO Drinking-Water Guidelines: Historical Chemical Reference

Historical chemical reference entries associated with WHO drinking-water guidance, their scope, and the current guideline framework.

Introduction to WHO Guidelines

WHO drinking-water guidance supports national standards and preventive risk management. This article retains a selected historical chemical comparison associated with the 1993 second edition; it is not the latest guideline table. The current consolidated fourth edition incorporates the first, second and third addenda and was published in 2026.

Use the current WHO edition and chemical fact sheets for present assessment, alongside applicable national law. The illustrative concentration column below is not a universal normal freshwater range. Reference entries also include acceptability or operational considerations, which must not be mistaken for health-based limits; “No guideline” does not establish harmlessness.

For a broader perspective on drinking water quality, you may also find our article on Drinking Water Standards insightful.

Inorganic Substances in Drinking Water

The presence of inorganic elements and compounds in drinking water can originate from natural geological formations, agricultural runoff, or industrial discharges. The WHO guidelines set health-based limits to mitigate potential risks.

Element/SubstanceSymbol/FormulaIllustrative reported concentration (not a universal range)Historical reference entry
AluminiumAl0.2 mg/L (0.2 ppm)No guideline
Ammonia/ammoniumNH₃/NH₄⁺< 0.2 mg/L (up to 0.3 mg/L in anaerobic waters)No guideline
AntimonySb< 4 µg/L (4 ppb)0.005 mg/L (5 ppb)
ArsenicAs0.01 mg/L (10 ppb)0.01 mg/L (10 ppb)
AsbestosNo guideline
BariumBa0.3 mg/L (0.3 ppm)0.7 mg/L (0.7 ppm)
BerylliumBe< 1 µg/L (1 ppb)No guideline
BoronB< 1 mg/L (1 ppm)0.3 mg/L (0.3 ppm)
CadmiumCd< 1 µg/L (1 ppb)0.003 mg/L (3 ppb)
ChlorideCl⁻250 mg/L (250 ppm)No health guideline; taste can be detectable above about 250 mg/L
ChromiumCr³⁺, Cr⁶⁺< 2 µg/L (2 ppb)0.05 mg/L (50 ppb)
ColourNot mentionedNo guideline
CopperCu2 mg/L (2 ppm)2 mg/L (2 ppm)
CyanideCN⁻0.07 mg/L (70 ppb)
Dissolved oxygenO₂No guideline
FluorideF< 1.5 mg/L (up to 10 mg/L)1.5 mg/L (1.5 ppm)
Hardnessmg/L CaCO₃No guideline
Hydrogen sulfideH₂SNo guideline
IronFe0.5 - 50 mg/L (0.5 - 50 ppm)No guideline
LeadPb0.01 mg/L (10 ppb)
ManganeseMn0.5 mg/L (0.5 ppm)0.5 mg/L (500 ppb), provisional in 1993
MercuryHg< 0.5 µg/L (0.5 ppb)0.001 mg/L (1 ppb)
MolybdenumMo< 0.01 mg/L (10 ppb)0.07 mg/L (70 ppb)
NickelNi< 0.02 mg/L (20 ppb)0.02 mg/L (20 ppb)
Nitrate and nitriteNO₃⁻, NO₂⁻Site-specific; measure separatelyNitrate: 50 mg/L as nitrate; nitrite: 3 mg/L as nitrite, provisional in 1993; not total nitrogen
TurbidityNot mentionedNo guideline
pHNo guideline
SeleniumSe< 0.01 mg/L (10 ppb)0.01 mg/L (10 ppb)
SilverAg5 – 50 µg/L (5 – 50 ppb)No guideline
SodiumNa< 20 mg/L (20 ppm)No health guideline; taste consideration around 200 mg/L
SulfateSO₄²⁻500 mg/L (500 ppm)No health guideline; assess sources above 500 mg/L with health authorities
Inorganic tinSnNo guideline
TDS (Total Dissolved Solids)No guideline
UraniumUNo chemical health guideline in 1993; approximately 0.14 mg/L natural uranium was a radiological equivalent, not a current chemical limit
ZincZn3 mg/L (3 ppm)No health guideline; acceptability problems above about 3 mg/L

Organic Compounds in Drinking Water

Organic compounds can enter drinking water sources from various anthropogenic activities, including industrial processes, agriculture, and urban runoff. The WHO guidelines provide limits for numerous organic contaminants.

Chlorinated Alkanes

SubstanceFormulaHistorical reference entry
Carbon tetrachlorideCCl₄2 µg/L (2 ppb)
DichloromethaneCH₂Cl₂20 µg/L (20 ppb)
1,1-DichloroethaneC₂H₄Cl₂No guideline
1,2-DichloroethaneClCH₂CH₂Cl30 µg/L (30 ppb)
1,1,1-TrichloroethaneCH₃CCl₃2000 µg/L (2000 ppb)

Chlorinated Ethenes

SubstanceFormulaHistorical reference entry
1,1-DichloroetheneC₂H₂Cl₂30 µg/L (30 ppb)
1,2-DichloroetheneC₂H₂Cl₂50 µg/L (50 ppb)
TrichloroetheneC₂HCl₃70 µg/L (70 ppb)
TetrachloroetheneC₂Cl₄40 µg/L (40 ppb)

Aromatic Hydrocarbons

SubstanceFormulaHistorical reference entry
BenzeneC₆H₆10 µg/L (10 ppb)
TolueneC₇H₈700 µg/L (700 ppb)
XylenesC₈H₁₀500 µg/L (500 ppb)
EthylbenzeneC₈H₁₀300 µg/L (300 ppb)
StyreneC₈H₈20 µg/L (20 ppb)

Polynuclear Aromatic Hydrocarbons (PAHs)

SubstanceFormulaHistorical reference entry
Benzo(a)pyreneC₂₀H₁₂0.7 µg/L (0.7 ppb)

The 0.7 µg/L entry refers to benzo(a)pyrene, not the sum of all PAHs. Other PAHs have different evidence and cannot be represented by one molecular formula.

Chlorinated Benzenes

SubstanceFormulaHistorical reference entry
Monochlorobenzene (MCB)C₆H₅Cl300 µg/L (300 ppb)
1,2-Dichlorobenzene (1,2-DCB)C₆H₄Cl₂1000 µg/L (1000 ppb)
1,3-Dichlorobenzene (1,3-DCB)C₆H₄Cl₂No guideline
1,4-Dichlorobenzene (1,4-DCB)C₆H₄Cl₂300 µg/L (300 ppb)
Trichlorobenzenes (TCBs)C₆H₃Cl₃20 µg/L (20 ppb)

Miscellaneous Organic Constituents

SubstanceFormulaHistorical reference entry
Di(2-ethylhexyl)adipate (DEHA)C₂₂H₄₂O₄80 µg/L (80 ppb)
Di(2-ethylhexyl)phthalate (DEHP)C₂₄H₃₈O₄8 µg/L (8 ppb)
AcrylamideC₃H₅NO0.5 µg/L (0.5 ppb)
Epichlorohydrin (ECH)C₃H₅ClO0.4 µg/L (0.4 ppb)
Hexachlorobutadiene (HCBD)C₄Cl₆0.6 µg/L (0.6 ppb)
Ethylenediaminetetraacetic acid (EDTA)C₁₀H₁₆N₂O₈200 µg/L (200 ppb)
Nitrilotriacetic acid (NTA)N(CH₂COOH)₃200 µg/L (200 ppb)

Organotins

SubstanceFormulaHistorical reference entry
DialkyltinsR₂SnX₂No guideline
Tributyltin oxide (TBTO)C₂₄H₅₄OSn₂2 µg/L (2 ppb)

Pesticides in Drinking Water

Pesticides are widely used in agriculture and can contaminate water sources through runoff and leaching. The WHO sets guidelines for various pesticides due to their potential health impacts.

SubstanceFormulaHistorical reference entry
AlachlorC₁₄H₂₀ClNO₂20 µg/L (20 ppb)
AldicarbC₇H₁₄N₂O₂S10 µg/L (10 ppb)
Aldrin and dieldrinC₁₂H₈Cl₆ / C₁₂H₈Cl₆O0.03 µg/L (0.03 ppb)
AtrazineC₈H₁₄ClN₅2 µg/L (2 ppb)
BentazoneC₁₀H₁₂N₂O₃S30 µg/L (30 ppb)
CarbofuranC₁₂H₁₅NO₃5 µg/L (5 ppb)
ChlordaneC₁₀H₆Cl₈0.2 µg/L (0.2 ppb)
ChlorotoluronC₁₀H₁₃ClN₂O30 µg/L (30 ppb)
DDTC₁₄H₉Cl₅2 µg/L (2 ppb)
1,2-Dibromo-3-chloropropaneC₃H₅Br₂Cl1 µg/L (1 ppb)
2,4-Dichlorophenoxyacetic acid (2,4-D)C₈H₆Cl₂O₃30 µg/L (30 ppb)
1,2-DichloropropaneC₃H₆Cl₂No guideline
1,3-DichloropropaneC₃H₆Cl₂No guideline
1,3-DichloropropeneC₃H₄Cl₂20 µg/L (20 ppb)
Ethylene dibromide (EDB)BrCH₂CH₂BrNo guideline
Heptachlor and heptachlor epoxideC₁₀H₅Cl₇ / C₁₀H₅Cl₇O0.03 µg/L (0.03 ppb)
Hexachlorobenzene (HCB)C₆Cl₆1 µg/L (1 ppb)
IsoproturonC₁₂H₁₈N₂O9 µg/L (9 ppb)
LindaneC₆H₆Cl₆2 µg/L (2 ppb)
MCPAC₉H₉ClO₃2 µg/L (2 ppb)
Methoxychlor(C₆H₄OCH₃)₂CHCCl₃20 µg/L (20 ppb)
MetolachlorC₁₅H₂₂ClNO₂10 µg/L (10 ppb)
MolinateC₉H₁₇NOS6 µg/L (6 ppb)
PendimethalinC₁₃H₁₉O₄N₃20 µg/L (20 ppb)
Pentachlorophenol (PCP)C₆HCl₅O9 µg/L (9 ppb)
PermethrinC₂₁H₂₀Cl₂O₃20 µg/L (20 ppb)
PropanilC₉H₉Cl₂NO20 µg/L (20 ppb)
PyridateC₁₉H₂₃ClN₂O₂S100 µg/L (100 ppb)
SimazineC₇H₁₂ClN₅2 µg/L (2 ppb)
TrifluralinC₁₃H₁₆F₃N₃O₄20 µg/L (20 ppb)

Chlorophenoxy Herbicides (excluding 2,4-D and MCPA)

SubstanceFormulaHistorical reference entry
2,4-DBC₁₀H₁₀Cl₂O₃90 µg/L (90 ppb)
DichlorpropC₉H₈Cl₂O₃100 µg/L (100 ppb)
FenopropC₉H₇Cl₃O₃9 µg/L (9 ppb)
MCPBC₁₁H₁₃ClO₃No guideline
MecopropC₁₀H₁₁ClO₃10 µg/L (10 ppb)
2,4,5-TC₈H₅Cl₃O₃9 µg/L (9 ppb)

Disinfectants and Disinfection By-products

Disinfectants are essential for treating drinking water, but they can react with natural organic matter to form disinfection by-products (DBPs), some of which may be harmful.

Disinfectants

SubstanceFormulaHistorical reference entry
MonochloramineNH₂Cl3 mg/L (3 ppm)
ChlorineCl₂5 mg/L (5 ppm)
Chlorine dioxideClO₂No guideline
IodineI₂No guideline

Disinfectant By-products

SubstanceFormulaHistorical reference entry
BromateBrO₃⁻25 µg/L (25 ppb)
ChlorateClO₃⁻No guideline
ChloriteClO₂⁻200 µg/L (200 ppb)
FormaldehydeHCHO900 µg/L (900 ppb)
MX (3-Chloro-4-dichloromethyl-5-hydroxy-2(5H)-furanone)C₅H₃Cl₃O₃No guideline
Cyanogen chlorideClCN70 µg/L (70 ppb)
ChloropicrinCCl₃NO₂No guideline

Chlorophenols

SubstanceFormulaHistorical reference entry
2-Chlorophenol (2-CP)C₆H₅ClONo guideline
2,4-Dichlorophenol (2,4-DCP)C₆H₄Cl₂ONo guideline
2,4,6-Trichlorophenol (2,4,6-TCP)C₆H₃Cl₃O200 µg/L (200 ppb)

Trihalomethanes

SubstanceFormulaHistorical reference entry
BromoformCHBr₃100 µg/L (100 ppb)
DibromochloromethaneCHBr₂Cl100 µg/L (100 ppb)
BromodichloromethaneCHBrCl₂60 µg/L (60 ppb)
ChloroformCHCl₃200 µg/L (200 ppb)

Chlorinated Acetic Acids

SubstanceFormulaHistorical reference entry
Monochloroacetic acidC₂H₃ClO₂No guideline
Dichloroacetic acidC₂H₂Cl₂O₂50 µg/L (50 ppb)
Trichloroacetic acidC₂HCl₃O₂100 µg/L (100 ppb)
Chloral hydrate (trichloroacetaldehyde)CCl₃CH(OH)₂10 µg/L (10 ppb)
ChloroacetonesC₃H₅OClNo guideline

Halogenated Acetonitriles

SubstanceFormulaHistorical reference entry
DichloroacetonitrileC₂HCl₂N90 µg/L (90 ppb)
DibromoacetonitrileC₂HBr₂N100 µg/L (100 ppb)
BromochloroacetonitrileC₂HBrClNNo guideline
TrichloroacetonitrileC₂Cl₃N1 µg/L (1 ppb)

AquaChain Engineering Tip

Plan sampling around source vulnerability and actual treatment. Where chlorination is used, assess DBPs such as trihalomethanes and haloacetic acids at relevant distribution points, and use competent laboratories and validated methods. WHO guidance informs this work, while legally enforceable compliance follows local law; chemical tables do not replace microbial control.

Frequently Asked Questions

Q: What is the primary purpose of the WHO Drinking-Water Quality Guidelines? A: The guidelines serve as an international reference to promote and protect public health by establishing a scientific basis for national drinking water quality standards and risk management strategies.

Q: Are these guidelines legally binding for all countries? A: No, the WHO guidelines are not legally binding; they are recommendations that countries adapt into their national regulations based on local conditions, resources, and priorities.

Q: Why are there "No guideline" entries for some substances? A: An absent guideline may reflect insufficient evidence, low exposure at expected concentrations, or a primarily operational or acceptability concern. It is not a finding of universal safety. Check the reason in the relevant current fact sheet and assess the actual exposure.

References