Introduction
Emergency potabilisation units can support humanitarian aid, disaster relief and temporary water supply when a suitable source, power and operating support are available. The skid-mounted, manually operated configuration described here is a Lenntech supplier example rated up to 2 cubic meters per hour (2,000 L/h or 528.3 US gallons per hour). Safe production depends on feedwater suitability, validated treatment performance and field acceptance; the nominal capacity does not establish World Health Organization (WHO) compliance.
Key Features of Emergency Potabilisation Units
The example combines the following treatment stages; their selection and operating settings must match the actual contaminants:
- Self-Priming Feed Pump: Equipped with an intake strainer for initial coarse debris removal.
- Coagulation and Flocculation: Chemical treatment to aggregate suspended solids.
- Roughing Filter: Utilizes gravel media for primary solids removal and enhanced flocculation.
- Advanced Media Filtration: Uses crushed glass media for finer particles; do not assign a microbial removal credit without validation.
- Activated Carbon Filtration: For the removal of undesirable taste, odor, and color.
- Microfiltration with Silver: Uses silver-impregnated candles; verify filtration rating, microbial test performance and silver release rather than assuming disinfection.
- Final Chlorination: Disinfection with readily available chlorine tablets.
System Design and Operation
Treatment Process Flow
The following supplier-example train must be assessed against source-water hazards and the required drinking-water quality:
- Raw Water Intake: A self-priming feed pump, fitted with a pre-filtration strainer, draws raw water into the system.
- Coagulation & Flocculation: Coagulants (e.g., ferric chloride, FeCl₃) and anionic flocculants are dosed via Dosatron systems to destabilize and aggregate suspended particles, preparing them for removal.
- Roughing Filtration: Water passes through a gravel-based roughing filter, effectively removing larger suspended solids and further enhancing flocculant effectiveness.
- Advanced Media Filtration: A crushed glass media filter removes finer suspended particles. Its bacterial removal performance must be demonstrated under the intended conditions.
- Activated Carbon Filtration: Water flows through an activated carbon filter, improving aesthetic qualities by adsorbing organic compounds responsible for taste, odor, and color.
- Polishing & Microfiltration: The example uses 0.3 micron (0.000012 inch) silver-impregnated candles. This nominal description alone does not prove a validated barrier for bacteria, viruses or protozoa; check challenge tests, integrity and silver release.
- Final Disinfection: Sodium Dichloroisocyanurate (NaDCC) is dosed with Dosatron equipment toward the example target of approximately 0.5 mg/L (0.5 ppm) free chlorine residual. This is not a fixed input dose or a guarantee against every pathogen. Set dose and contact time from demand, temperature, pH, target organisms and safe storage/distribution conditions.
Technical Specifications
The following values describe the Lenntech example, not a generic specification for all emergency units. Confirm the delivered configuration, operating duty and dimensional orientation:
| Parameter | Specification (Metric) | Specification (Imperial) | Notes |
|---|---|---|---|
| Capacity | 2,000 L/h (2 m³/h) | 528.3 US GPH | Up to |
| Power Requirements | 3 kW | 3 kW | |
| Feed Pump Discharge | 2.5 bar | 36.3 psi | With pre-filtration strainer |
| Coagulant | Dosatron FeCl₃ | Dosatron FeCl₃ | |
| Flocculant | Dosatron PE anionic | Dosatron PE anionic | |
| Roughing Filter Flux | 10 m³/h·m² | 4.09 US GPM/ft² | Gravel media |
| Advanced Filter Flux | 10 m³/h·m² | 4.09 US GPM/ft² | Crushed glass media |
| Activated Carbon CT | 12 minutes | 12 minutes | Contact Time |
| Polishing Step | 0.3 µm silver candles | 0.3 µm silver candles | |
| Chlorination | Dosatron NaDCC | Dosatron NaDCC | Target 0.5 mg/L (0.5 ppm) Cl₂ residual |
| Published Dimensions | 2.2 m x 1.2 m x 1.1 m | 7.22 ft x 3.94 ft x 3.61 ft | Confirm length/width/height orientation before installation |
| Weight (Empty) | 300 kg | 661.4 lbs | Approximate |
Consumables and Spare Parts
The supplier lists the following approximately one-year consumable inventory and basic spares. Actual duration depends on operating hours, water quality, dose, backwashing and cartridge loading; this inventory does not guarantee a year of uninterrupted operation:
- Consumables (approx. 1 year supply):
- Coagulant: 200 kg (440.9 lbs)
- Flocculant: 20 kg (44.1 lbs)
- NaDCC 55% Cl₂: 20 kg (44.1 lbs)
- Silver Cartridges: 1 box (12 units)
- Essential Tools/Spares:
- 25 L (6.6 US gallon) Buckets
- Pump repair kit
Treated Water Quality and Standards
The supplier example targets treated-water turbidity below 1 Nephelometric Turbidity Unit (NTU). Turbidity and chlorine residual are useful operating controls, but neither proves removal of every microbial or chemical hazard. Verify actual source and treated-water tests, validated barriers, safe storage, and the applicable Drinking Water Standards. A generic ISO quality-control claim does not establish compliance with World Health Organization (WHO) guidance or local drinking-water requirements.
AquaChain Engineering Tip
For emergency potabilisation units, it is critical to implement a robust pre-treatment strategy for raw water intake. While the unit includes a strainer, often large debris or excessive turbidity can overwhelm the system. Deploying a simple, coarse pre-screen (e.g., a basket filter or even a fine mesh netting) at the intake point significantly reduces the load on the roughing filter and extends the operational life of the entire system, especially in highly turbid surface water sources.
Frequently Asked Questions
Q1: What is the primary purpose of an emergency potabilisation unit? A1: They can provide temporary drinking-water treatment for humanitarian crises, disaster relief, military or remote applications after confirming source suitability and field acceptance. A portable train cannot make every contaminated source safe without additional treatment.
Q2: Why are these units designed for manual operation? A2: Manual controls can simplify setup and troubleshooting, but still require trained operation, dependable power for pumping, chemical handling and water-quality monitoring. Intermittent power and limited staffing must be included in the deployment plan.
Q3: How is the quality of the treated water verified? A3: Monitor turbidity (the example target is <1 NTU) and chlorine residual (the example target is 0.5 mg/L), then verify the necessary microbial and chemical parameters against local requirements and a water-safety plan. Confirm any claimed ISO standard by its actual scope; it is not by itself evidence of WHO drinking-water compliance.