A technical guide for calculating and designing packed column degassers, focusing on CO2 removal in post-reverse osmosis water treatment processes.

Understanding Degassing in Water Treatment

Degassing removes dissolved gases after processes such as reverse osmosis (RO). This guide addresses dissolved carbon dioxide (CO₂) removal by countercurrent packed air-stripping columns. Ambient air commonly adds oxygen rather than removing dissolved oxygen; oxygen removal needs an appropriate vacuum, steam or inert-gas process. Exhaust containing hazardous gases or volatile contaminants requires suitable collection and treatment.

The Challenge of Dissolved Carbon Dioxide

Groundwater and other sources often contain dissolved CO₂. In water, CO₂ exists in equilibrium with bicarbonate (HCO₃⁻) and carbonate (CO₃²⁻) ions.

Equilibrium Equation: CO₂ + H₂O ⇌ H₂CO₃ ⇌ H⁺ + HCO₃⁻ ⇌ 2H⁺ + CO₃²⁻

During the reverse osmosis process, semipermeable membranes efficiently remove dissolved ions like HCO₃⁻ and CO₃²⁻, channeling them into the concentrate stream. However, dissolved CO₂, being a non-ionic gas, can largely pass through the RO membrane. This leads to a decrease in the pH of the permeate (treated water), making it more acidic.

Removing dissolved CO₂ can raise permeate pH, reduce downstream ionic-polishing load and help corrosion control. It does not automatically produce neutral water: alkalinity, speciation, air CO₂ and treatment targets govern the endpoint. Check the actual downstream material and membrane pH limits; low-pH permeate does not imply universal membrane damage. Packed stripping towers are one available approach.

Fundamental Principles of Degasser Design

The design of a degasser, especially a packed column stripper, relies on understanding gas-liquid mass transfer principles.

Henry's Law and Constant

Henry’s law relates the equilibrium concentration of an infinitely dilute molecular gas in water to its gas-phase partial pressure. Define the solubility constant Hcp=CL/pH_{cp}=C_L/p in mol/(m³·Pa), and the dimensionless volatility ratio Hcc=Cg∗/CLH_{cc}=C_g^*/C_L. With gas concentration in mol/m³ and the ideal-gas relation, Hcc=1/(RTHcp)H_{cc}=1/(R T H_{cp}). These definitions are reciprocal after the gas-law conversion, not interchangeable numerical constants.

Near a reference temperature, a selected paired solubility constant and temperature slope can be used as follows. Use the original data range for wider temperature changes:

Hcp(T)=Hcp,refexp⁡[λ(1T−1Tref)],Hcc(T)=1RTHcp(T)H_{cp}(T)=H_{cp,ref}\exp\left[\lambda\left(\frac{1}{T}-\frac{1}{T_{ref}}\right)\right],\qquad H_{cc}(T)=\frac{1}{R T H_{cp}(T)}

Where:

  • Hcp(T)H_{cp}(T) = Molecular-gas solubility constant at temperature T [mol/(m³·Pa)]
  • Hcp,refH_{cp,ref} = Selected constant at Tref=298.15 KT_{ref}=298.15\text{ K} (25°C)
  • λ=dln⁡Hcp/d(1/T)\lambda=d\ln H_{cp}/d(1/T) = Temperature slope at the reference state [K]; not automatically a standard solution enthalpy
  • R=8.314 J/(mol⋅K)R=8.314\text{ J/(mol}\cdot\text{K)}; match Pa, mol and m³ rather than mixing bar or mass-based solubility constants
  • TT = Absolute temperature [K]; reactive acid/base systems require molecular-species equilibrium, not total analytical concentration

Table 1: Selected molecular-gas Henry data at 25°C (298.15 K), with calculated dimensionless gas/liquid ratios

ComponentHcp,refH_{cp,ref} [mol/(m³·Pa)]λ\lambda [K]HccH_{cc} at 25°C
Ammonia0.5942006.84e-4
Carbon dioxide3.40e-423001.19
Molecular chlorine6.10e-432000.661
Chlorine dioxide0.0135000.0403
Hydrogen sulfide0.00121000.403
Methane1.40e-5160028.8
Oxygen1.30e-5150031
Ozone1.00e-428004.03
Sulfur dioxide0.01329000.031
Carbon tetrachloride3.40e-442001.19
Tetrachloroethene5.70e-447000.708
Benzene0.001838000.224
Chloroform0.002742000.149

The selected paired entries are from the Sander 2023 database: literature-review records except molecular chlorine, an original measurement. HccH_{cc} is calculated using ideal-gas concentrations at 298.15 K, not measured equipment performance. Acid/base reactions (including ammonia/ammonium, carbonates, sulfides, sulfur dioxide and chlorine hydrolysis), salinity and wider temperature ranges require separate assessment; do not use molecular-gas constants for total analytical species.

Minimum Air/Water Ratio and Stripping Factor

For clean incoming gas and dilute linear equilibrium, the minimum volumetric air/water ratio depends on target removal. A ratio below the minimum cannot attain the target; equality is an ideal equilibrium pinch requiring unlimited contact height.

For inlet water C0>0C_0>0, target 0<Cu<C00<C_u<C_0 and known HccH_{cc}, the clean-gas minimum is rmin=(1−Cu/C0)/Hccr_{min}=(1-C_u/C_0)/H_{cc}. Actual gas flow must be stated at tower temperature and pressure. Incoming gas contamination creates an additional equilibrium floor.

Here the conventional stripping factor is S=Hcc(Qa/Qw)S=H_{cc}(Q_a/Q_w). The distinct design margin ϕ\phi is actual air/water ratio divided by its target-specific minimum; they must not be confused:

S=HccQaQw,rmin=1−Cu/C0Hcc,ϕ=Qa/QwrminS=H_{cc}\frac{Q_a}{Q_w},\qquad r_{min}=\frac{1-C_u/C_0}{H_{cc}},\qquad \phi=\frac{Q_a/Q_w}{r_{min}}

  • If S<1−Cu/C0S<1-C_u/C_0 (equivalently ϕ<1\phi<1 for clean inlet gas), the target is infeasible. A value S<1S<1 by itself does not prove failure.
  • If S=1−Cu/C0S=1-C_u/C_0 (ϕ=1\phi=1), an ideal clean-gas column is at the pinch; finite packing height cannot attain that exact target.
  • Choose S>1−Cu/C0S>1-C_u/C_0 and sufficient mass transfer/contact height. This inequality alone is not a removal guarantee; allow for inlet gas contamination, fouling and operating variation.

Degasser Design Procedure

Designing a packed column degasser involves several steps to determine its dimensions and operating parameters.

Step 1: Define Design Criteria and Select Packing

Crucial design criteria include:

  • Packing Factor (CfC_f): Obtain the chosen packing’s hydraulic factor with the exact units and curve convention specified by the supplier.
  • Air/Water Ratio: Determined based on desired removal and Henry's constant.
  • Gas Pressure Drop: A preliminary example target is 50 Pa/m50\text{ Pa/m} (approximately 0.0022 psi/ft0.0022\text{ psi/ft}); choose the actual gradient from hydraulics, flooding margin and blower energy.

Table 2: Illustrative packing geometry and wetting data; obtain verified hydraulic factors for the selected packing

Packing typeNominal diameter [m (in)]Hydraulic factor CfC_fIllustrative surface ata_t [m²/m³]Illustrative critical tension σc\sigma_c [N/m (lbf/ft)]
Nor-Pac0.0508 (2.0)Supplier value; match curve units102.00.033 (0.00226)
Plastic Tri-Pac0.0508 (2.0)Supplier value; match curve units157.00.033 (0.00226)
Nor-Pac0.0381 (1.5)Supplier value; match curve units144.00.033 (0.00226)
Flex ring0.0508 (2.0)Supplier value; match curve units115.00.033 (0.00226)
Pall Ring0.0508 (2.0)Supplier value; match curve units102.00.033 (0.00226)

Step 2: Determine Fluid Densities and Eckert Curve X-Value

Use the pressure-drop or generalized pressure-drop correlation specified for the selected packing to size the cross-section. A common Eckert flow parameter uses liquid/gas mass loading, not the inverse:

x=LmGmρGρL−ρGx=\frac{L_m}{G_m}\sqrt{\frac{\rho_G}{\rho_L-\rho_G}}

Where:

  • ρL\rho_L = Density of water [kg/m³]
  • ρG\rho_G = Density of gas (air) [kg/m³]
  • Lm/GmL_m/G_m = Liquid/gas mass-flux ratio [dimensionless]; ρL−ρG\rho_L-\rho_G is the density difference

A. Water Density (ρL\rho_L) Calculation

For a small temperature change near a reference T1=293.15 KT_1=293.15\text{ K} (20∘C20^\circ\text{C}), a local expansion approximation can estimate water volume. For a wider range or precise design, use validated water properties at the actual temperature and pressure:

ΔV=V0⋅β⋅ΔT\Delta V = V_0 \cdot \beta \cdot \Delta T

Where:

  • ΔV\Delta V = Volume change [m³]
  • V0V_0 = Original volume (e.g., 1 m31 \text{ m}^3)
  • β\beta = Local water volumetric expansion coefficient, approximately 0.21×10−3 K−10.21\times10^{-3}\text{ K}^{-1} near 293.15 K293.15\text{ K}; not constant across all temperatures
  • ΔT=T2−T1\Delta T = T_2 - T_1 = Temperature difference [K]

For a fixed water mass mwm_w [kg], the new volume is V0+ΔVV_0+\Delta V; use a reference density to establish that mass before calculating:

ρL=mwV0+ΔV\rho_L=\frac{m_w}{V_0+\Delta V}

B. Air Density (ρG\rho_G) Calculation

The density of air at a certain temperature (TT) can be determined using the ideal gas law:

ρG=P⋅MR⋅T\rho_G = \frac{P \cdot M}{R \cdot T}

Where:

  • PP = Absolute operating air pressure in Pa; 1 atm=101.325 kPa1\text{ atm}=101.325\text{ kPa}, with local elevation and blower pressure considered
  • MM = Molar mass of air (28.97 kg/kmol28.97 \text{ kg/kmol} or 0.02897 kg/mol0.02897 \text{ kg/mol})
  • RR = Universal gas constant (8314 J/(kmol⋅K)8314 \text{ J/(kmol} \cdot \text{K)} or 8.314 J/(mol⋅K)8.314 \text{ J/(mol} \cdot \text{K)})
  • TT = Absolute temperature in Kelvin (K)

C. Mass Flux Ratio (Gm/LmG_m/L_m)

With gas and liquid flowing through the same column area, mass-flux ratio is determined from actual volumetric rates and both densities:

GmLm=QaρGQwρL\frac{G_m}{L_m}=\frac{Q_a\rho_G}{Q_w\rho_L}

Where:

  • QaQ_a = Actual air volume flow at tower temperature/pressure [m³/s], not an unconverted standard-volume rate
  • QwQ_w = Water flow rate [m³/s]

Step 3: Determine 'y' on the Eckert Curve

Select the curve for the chosen packing, pressure-drop gradient and valid loading range. Read its ordinate from the calculated flow parameter using that curve’s own units and viscosity corrections:

y=ychart(x,ΔPZ,packing)y=y_{chart}\left(x,\frac{\Delta P}{Z},\text{packing}\right)

This notation means chart lookup, not a universal algebraic fit. No unidentified “red curve” or fixed power-law fit establishes the chosen pressure-drop limit. Verify allowable superficial gas velocity and flooding margin with the supplier’s hydraulic correlation.

Step 4: Calculate Gas Mass Flux (GmG_m)

Use the allowable superficial gas velocity uGu_G [m/s] obtained from the verified hydraulic correlation at the selected gas/liquid loading. Convert it to gas mass flux:

Gm=ρGuGG_m=\rho_G u_G

Where:

  • GmG_m = Mass flux of gas [kg/(m²·s)]
  • CfC_f = Supplier hydraulic factor, used only with its documented chart definition and unit basis
  • gg = Gravitational acceleration (9.81 m/s29.81 \text{ m/s}^2)
  • μL\mu_L = Water dynamic viscosity [kg/(m·s) = Pa·s]; convert to any viscosity unit required by the selected chart

Dynamic Viscosity of Water (μL\mu_L) Use a validated water-property correlation or table at the actual temperature and pressure. At atmospheric pressure, a useful reference at 20°C is:

μL(293.15 K,1 atm)≈1.002×10−3 Pa⋅s=1.002 cP\mu_L(293.15\text{ K},1\text{ atm})\approx1.002\times10^{-3}\text{ Pa}\cdot\text{s}=1.002\text{ cP}

Where:

  • μL\mu_L = Dynamic viscosity of water [kg/(m·s)]
  • TT = Temperature [K]; obtain the corresponding property rather than holding the 20°C value fixed for other temperatures

Once fluid properties and hydraulic capacity are known, obtain GmG_m and verify the permitted operating margin below flooding.

Step 5: Calculate Water Mass Flux (LmL_m) and Column Cross-Section

The mass flux of the water (LmL_m) can be calculated from the gas mass flux and the mass flux ratio:

Lm=GmQwρLQaρGL_m=G_m\frac{Q_w\rho_L}{Q_a\rho_G}

Finally, the cross-sectional area (A) of the stripping column can be determined using the water flow rate (QwQ_w) and its density (ρL\rho_L):

A=Qw⋅ρLLmA = \frac{Q_w \cdot \rho_L}{L_m}

For a circular tower, dcol=4A/πd_{col}=\sqrt{4A/\pi}. Recheck liquid distribution, minimum wetting, turndown and gas pressure drop at this diameter.

Mass Transfer Coefficients and Column Height

To determine the required height of the stripping column, the overall mass transfer coefficient and individual diffusion coefficients are needed.

Diffusion Coefficients

Mass transfer occurs via diffusion from the water phase to the air phase. The diffusion coefficient depends on temperature and the properties of the diffusing substance (CO₂) and the medium (water or air).

A. Diffusion Coefficient of CO₂ in Water (DLD_L) The Hayduk–Laudie relation estimates aqueous diffusion of dilute non-electrolytes, with a specific empirical unit convention:

DL=13.26×10−5μW1.14⋅VB0.589D_L = \frac{13.26 \times 10^{-5}}{\mu_W^{1.14} \cdot V_B^{0.589}}

Where:

  • DLD_L = Diffusion coefficient of CO₂ in water [cm²/s (10−4 m2/s10^{-4} \text{ m}^2/\text{s})]
  • μW\mu_W = Dynamic viscosity of water [cP] (1 kg/(m⋅s)=1000 cP1 \text{ kg/(m·s)} = 1000 \text{ cP})
  • VBV_B = Solute molar volume parameter [cm³/mol], conventionally at the normal boiling point. CO₂ has no liquid normal boiling point at 1 atm: 194.6 K is near sublimation. Use a validated CO₂ volume estimate within the selected method or measured diffusion data; do not insert liters/mol without conversion.

B. Diffusion Coefficient of CO₂ in Air (DGD_G) A dilute-gas Chapman–Enskog correlation estimates CO₂ diffusion in air using Lennard–Jones parameters and a diffusion collision integral:

DG=1.8583×10−3T3/21/MA+1/MBPσAB2ΩD(T∗)D_G=\frac{1.8583\times10^{-3}T^{3/2}\sqrt{1/M_A+1/M_B}}{P\sigma_{AB}^2\Omega_D(T^*)}

Where:

  • DGD_G = Diffusion coefficient of CO₂ in air [cm²/s (10−4 m2/s10^{-4} \text{ m}^2/\text{s})]
  • TT = Temperature [Kelvin]
  • MAM_A = Molecular weight of CO₂ (44.01 g/mol44.01 \text{ g/mol})
  • MBM_B = Molecular weight of air (28.97 g/mol28.97 \text{ g/mol})
  • PP = Absolute gas pressure in atm for this coefficient; 1 atm=101325 Pa1\text{ atm}=101325\text{ Pa}, so Pa cannot be inserted directly
  • σAB=(σA+σB)/2\sigma_{AB}=(\sigma_A+\sigma_B)/2 = Mean Lennard–Jones collision diameter [Å] for this coefficient
    • σA\sigma_A for CO₂ = 3.941 A˚=0.3941 nm3.941\text{ Å}=0.3941\text{ nm}
    • σB\sigma_B for air = 3.711 A˚=0.3711 nm3.711\text{ Å}=0.3711\text{ nm}
  • ϵAB/k=(ϵA/k)(ϵB/k)\epsilon_{AB}/k=\sqrt{(\epsilon_A/k)(\epsilon_B/k)} = Combined energy temperature [K]
    • ϵA/k\epsilon_A/k for CO₂ = 195.2 K195.2\text{ K}; this parameter is not obtained by treating the sublimation temperature as a liquid boiling point
    • ϵB/k\epsilon_B / k (for air) = 78.6 K78.6 \text{ K}
  • kk = Boltzmann's constant (1.38×10−16 g⋅cm2/(s2⋅K)1.38 \times 10^{-16} \text{ g·cm}^2/(\text{s}^2 \cdot \text{K}) or 1.38×10−23 J/K1.38 \times 10^{-23} \text{ J/K})
  • ΩD(T∗)\Omega_D(T^*) = Dimensionless diffusion collision integral; the Neufeld fit below applies for 0.3≤T∗≤1000.3\le T^*\le100
    • T∗=T/(ϵAB/k)T^*=T/(\epsilon_{AB}/k).
    • ΩD(T∗)=1.06036(T∗)0.15610+0.19300e−0.47635T∗+1.03587e−1.52996T∗+1.76474e−3.89411T∗\Omega_D(T^*)=\frac{1.06036}{(T^*)^{0.15610}}+0.19300e^{-0.47635T^*}+1.03587e^{-1.52996T^*}+1.76474e^{-3.89411T^*}

C. Dynamic Viscosity of Air (μG\mu_G) For dilute air near atmospheric conditions, use the Sutherland approximation with consistent absolute temperatures:

μG=μ0(TT0)3/2T0+SμT+Sμ\mu_G=\mu_0\left(\frac{T}{T_0}\right)^{3/2}\frac{T_0+S_\mu}{T+S_\mu}

Where:

  • μG\mu_G = Dynamic viscosity of air [kg/(m·s)]
  • μ0=1.716×10−5 Pa⋅s\mu_0=1.716\times10^{-5}\text{ Pa}\cdot\text{s} = Reference air viscosity
  • T0=273.15 KT_0=273.15\text{ K} = Reference temperature
  • Sμ=110.4 KS_\mu=110.4\text{ K} = Sutherland temperature offset, distinct from the stripping factor
  • TT = Air temperature [K]; use validated mixture/high-pressure data when the dilute-air approximation is inappropriate

Total Mass Transfer Constant (KL⋅aK_L \cdot a)

On a liquid-concentration basis, combine liquid-side velocity coefficient kLk_L, gas-side concentration-based velocity coefficient kgk_g and wetted area:

1KLa=1kLaw+1Hcckgaw\frac{1}{K_L a}=\frac{1}{k_L a_w}+\frac{1}{H_{cc}k_g a_w}

Where:

  • KL⋅aK_L \cdot a = Total mass transfer constant [s⁻¹]
  • kLk_L = Liquid-side mass transfer coefficient [m/s]
  • kgk_g = Gas-side concentration-based mass-transfer coefficient [m/s], distinct from pressure-based kG(p)k_G^{(p)}
  • awa_w = Wetted surface area of the packing [m²/m³]
  • HccH_{cc} = Dimensionless equilibrium gas/liquid concentration ratio at the actual temperature

Onda Correlations for Mass Transfer Coefficients

The Onda empirical correlations estimate awa_w, kLk_L and gas-side transfer for suitable random packings. Use one coherent unit system. The original pressure-based gas coefficient kG(p)k_G^{(p)} converts to the velocity coefficient kg=kG(p)RTk_g=k_G^{(p)}RT used here.

A. Wetted Surface Area (awa_w) aw=at(1−e−1.45⋅ReL0.1⋅FrL−0.05⋅WeL0.2⋅(σC/σ)0.75)a_w = a_t \left( 1 - e^{-1.45 \cdot Re_L^{0.1} \cdot Fr_L^{-0.05} \cdot We_L^{0.2} \cdot (\sigma_C / \sigma)^{0.75}} \right)

Where:

  • ata_t = Specific surface area of the packing [m²/m³]
  • σ\sigma = Surface tension of water [kg/s² (N/m)]
  • σC\sigma_C = Critical surface tension of the packing material [kg/s² (N/m)]
  • ReLRe_L = Liquid Reynolds number
  • FrLFr_L = Liquid Froude number
  • WeLWe_L = Liquid Weber number

Dimensionless Numbers:

  • Liquid Reynolds Number (ReLRe_L): ReL=LmatμLRe_L=\frac{L_m}{a_t\mu_L}
  • Liquid Froude Number (FrLFr_L): FrL=atLm2gρL2Fr_L=\frac{a_t L_m^2}{g\rho_L^2}
  • Liquid Weber Number (WeLWe_L): WeL=Lm2ρLσatWe_L=\frac{L_m^2}{\rho_L\sigma a_t}

Where:

  • LmL_m = Mass flux of water [kg/(m²·s)]
  • dPd_P = Nominal diameter of the packing [m]
  • μL\mu_L = Dynamic viscosity of water [kg/(m·s)]
  • ρL\rho_L = Density of water [kg/m³]
  • gg = Gravitational acceleration (9.81 m/s29.81 \text{ m/s}^2)

B. Liquid-Side Mass Transfer Coefficient (kLk_L) kL(ρLμLg)1/3=0.0051(LmawμL)2/3(μLρLDL)−1/2(atdP)0.4k_L\left(\frac{\rho_L}{\mu_Lg}\right)^{1/3}=0.0051\left(\frac{L_m}{a_w\mu_L}\right)^{2/3}\left(\frac{\mu_L}{\rho_LD_L}\right)^{-1/2}(a_td_P)^{0.4}

Where:

  • DLD_L = Diffusion coefficient of CO₂ in water [m²/s]

C. Gas-Side Mass Transfer Coefficient (kgk_g) kgatDG=5.23(GmatμG)0.7(μGρGDG)1/3(atdP)−2,kg=kG(p)RT\frac{k_g}{a_tD_G}=5.23\left(\frac{G_m}{a_t\mu_G}\right)^{0.7}\left(\frac{\mu_G}{\rho_GD_G}\right)^{1/3}(a_td_P)^{-2},\qquad k_g=k_G^{(p)}RT

Where:

  • GmG_m = Mass flux of air [kg/(m²·s)]
  • μG\mu_G = Dynamic viscosity of air [kg/(m·s)]
  • ρG\rho_G = Density of air [kg/m³]
  • DGD_G = Diffusion coefficient of CO₂ in air [m²/s]

Conditions for Onda Correlations:

  • These correlations are empirical for the packing and loading regimes studied; they are not universally valid for every modern geometry or contaminated water.
  • In the original gas correlation, use coefficient 2.002.00 instead of 5.235.23 for Raschig rings or Berl saddles smaller than 15 mm15\text{ mm}.
  • Use consistent seconds-based mass flux, viscosity and diffusivity here. Do not mix the original hours-based property values into seconds-based calculations.
  • Confirm geometry, wetting, distribution, loading range and scale-up using supplier/pilot data. There is no universal diameter threshold that justifies multiplying KLaK_La by 0.750.75.

Column Height Determination

For countercurrent dilute stripping with constant flows, temperature, pressure and KLaK_La, linear molecular-species Henry equilibrium gives Cg=Cg,in+(CL−Cu)/(Qa/Qw)C_g=C_{g,in}+(C_L-C_u)/(Q_a/Q_w). Integrating the liquid-side driving force gives the packing height below. Require positive driving force throughout; for S=1S=1, use NTU=(C0−Cu)/(Cu−Cg,in/Hcc)NTU=(C_0-C_u)/(C_u-C_{g,in}/H_{cc}) rather than the singular logarithmic form.

α=1−1S,β=CuS−Cg,inHcc,NTU=1αln⁡(αC0+βαCu+β),Z=QwAKLaNTU\alpha=1-\frac{1}{S},\quad\beta=\frac{C_u}{S}-\frac{C_{g,in}}{H_{cc}},\quad NTU=\frac{1}{\alpha}\ln\left(\frac{\alpha C_0+\beta}{\alpha C_u+\beta}\right),\quad Z=\frac{Q_w}{A K_L a}NTU

Where:

  • ZZ = Required packing height [m]; total tower height also includes distributors, supports, freeboard and mist separation
  • QwQ_w = Water flow rate [m³/s]
  • AA = Cross-sectional area of the column [m²]
  • KL⋅aK_L \cdot a = Total mass transfer constant [s⁻¹]
  • C0C_0 = Inlet dissolved molecular-species concentration [mol/m³]; Cg,inC_{g,in} = Incoming gas concentration in the same molar-volume units
  • CuC_u = Target dissolved molecular-species concentration [mol/m³], with 0<Cu<C00<C_u<C_0; acid/base replenishment and reactions need additional modeling
  • S=HccQa/QwS=H_{cc}Q_a/Q_w = Conventional stripping factor. Check both end-point driving forces and the incoming-gas equilibrium floor before applying the formula.

AquaChain Engineering Tip

For preliminary design, obtain the selected packing’s verified hydraulic factor (CfC_f), surface area (ata_t) and pressure-drop/transfer data. Pilot actual water and incoming air, including pH/alkalinity, contamination, fouling and distribution. Account for exhaust treatment, oxygen pickup, hygienic air filtration and the complete blower/duct/distributor pressure drop.

Frequently Asked Questions

Q1: Why is CO₂ removal particularly important after reverse osmosis? A1: RO rejects bicarbonate and other ions while molecular CO₂ can pass, reducing permeate pH and increasing downstream polishing load. CO₂ removal can support pH stabilization and corrosion control, but the final pH and compatibility depend on alkalinity, air composition and actual material/membrane limits.

Q2: What is the significance of the stripping factor (S) in degasser design? A2: Here S=HccQa/QwS=H_{cc}Q_a/Q_w describes air flow relative to molecular-gas equilibrium. For clean incoming air, the target-specific minimum is Smin=1−Cu/C0S_{min}=1-C_u/C_0; adequate height and mass transfer are also necessary. The actual/minimum flow margin ϕ\phi is a different quantity. Nonzero incoming gas contamination adds an equilibrium floor.

Q3: Are there any alternatives to packed column degassers for CO₂ removal? A3: While packed columns are common, other methods include spray towers, tray columns, and membrane contactors. The choice depends on factors like desired removal efficiency, flow rate, footprint, and operating costs. For very high purity requirements or specific gas compositions, membrane contactors can offer advantages.

Learn more about related processes: Deaeration Technology