Condensate contamination, recovery and corrosion products
Use this when condensate contamination, recovery and corrosion products is observed but the cause remains unclear. The diagnostic checks measurement and sampling, operating changes, issue location, and key evidence before suggesting likely causes and the next useful check.
First time here? Start with this
You do not need every data point before you begin
The system asks one discriminating question at a time and updates the candidate causes on the right. Answer from current facts; choose unknown or defer a question when the evidence is not available.
- 1
Confirm the issue
Check whether the symptom is reproducible and whether the measurement or observation is reliable.
- 2
Narrow the causes
Continue through operating changes, issue location, and available inspection results.
- 3
Read the live result
Candidate causes, support, counter-evidence, conflicts, and next actions update as you answer.
This tool analyzes information you already have. It does not insert a safety screen or use safety status to stop the diagnosis. If an alarm, leak, or injury is happening now, follow the site emergency procedure directly.
Automatic troubleshooting · Selections are not uploaded
Only one question is shown at a time. Answer from current facts or defer an unknown item. Possible causes and next checks update on the right as you answer.
- 1Data validity
- 2Operating changes
- 3Issue location
- 4Further confirmation
Question progress
0/32
- Answered
- 0
- To confirm
- 32
- Clues found
- 0
Load a test scenario
Next question
Phase 1 · Data validity
What is the state of unit type, pressure, metallurgy, treatment method, and condensate targets?
The system asks the question most useful for separating possible causes. Unknown or deferred items are not treated as the opposite conclusion.
I have more test or inspection resultsOptionalAdd laboratory analysis, normalized calculations, or checks completed by trained personnel when available. These fields are optional.
View rule sources (17)Standards, regulations, OEM material, and peer-reviewed literature used to audit the diagnostic logic. You do not need to read them before starting.
Each rule cites material directly relevant to its judgment. Current OEM and site procedures remain controlling.
- A-international-expert-guidance-current · IAPWS · 2014IAPWS TGD6-13(2014) Corrosion Product Sampling and Analysis for Fossil and Combined Cycle Plants
- B-international-expert-white-paper-current · IAPWS · 2025IAPWS PCC White Paper on Corrosion Product Sampling, Monitoring and Analysis for Flexible and Fast Starting Plants
- A-international-expert-guidance-current · IAPWS · 2024IAPWS TGD2-09(2024) Cycle Chemistry Instrumentation
- A-international-expert-guidance-current · IAPWS · 2015IAPWS TGD3-10(2015) Volatile Treatments for Steam-Water Circuits
- A-international-expert-guidance-current · IAPWS · 2019IAPWS TGD8-16(2019) Application of Film Forming Substances
- A-international-expert-guidance-current · IAPWS · 2013IAPWS TGD5-13 Steam Purity for Turbine Operation
- A-consensus-standard-current-reaffirmed · ASME · 2018ASME PTC 19.11-2008 (R2018) Steam and Water Sampling
- A-consensus-standard-current · ASTM International · 2025ASTM D3370-25 Standard Practices for Sampling Water from Flowing Process Streams
- A-consensus-standard-current-reapproved · ASTM International · 2025ASTM D1066-18(2025) Standard Practice for Sampling Steam
- A-consensus-standard-current · ASTM International · 2020ASTM D1976-20 Standard Test Method for Elements in Water by ICP-AES
- A-consensus-standard-current-reapproved · ASTM International · 2025ASTM D1688-17(2025) Standard Test Methods for Copper in Water
- A-international-standard-current · ISO · 2017ISO/IEC 17025:2017 Testing and calibration laboratories
- A-government-guide · US DOE · 2012DOE Steam Tip Sheet #8 — Return Condensate to the Boiler
- A-government-guide · US DOE · 2012DOE Improving Steam System Performance: A Sourcebook for Industry
- B-oem-technical-handbook-current · Veolia Water Technologies · 2026Veolia Water Handbook — Condensate System Corrosion
- B-oem-technical-guide-current · Spirax Sarco · 2026Spirax Sarco — Lifting Condensate and Contaminated Condensate
- A-government-safety-current · US OSHA · 2026OSHA Control of Hazardous Energy