Datasheet summary
ROSave.Z
Engineering summary from PDF text extraction for ROSave.Z. Verify every value with the OEM datasheet.
Summary
Product identification
ROSave.Z* is a Z.Plex* technology depth filter engineered specifically for reverse osmosis pretreatment and suitable for many pure water applications. It features a thermally bonded construction and mel-bonded end adaption.
Features and Benefits
- Engineered specifically for reverse osmosis pretreatment and suitable for many pure water applications
- Depth filter traps particles throughout the media
- True depth media offers longer filter lifetime
- Very low pressure drop and flow resistance
- Thermally bonded construction and mel-bonded end adaption
Applications
- Reverse osmosis pre-filtration for Veolia RO systems and universal equipment
- Beverage
- Electronics
- Pre/post DI or active carbon
Specifications
Micron Ratings
- Nominal Ratings: 1, 5 microns
- Efficiency of nominal filters varies by application. Nominal-rated filters have a wider distribution of pore sizes and rejected particle sizes, primarily used to compare efficiencies across filter families and between manufacturers. Efficiency depends on particle shape, size, composition, application, and testing protocol.
Dimensions
- Inner Diameter (nominal): 1 in (2.5 cm)
- Outer Diameter: 2.5 in (6.4 cm)
- Lengths:
- 9 3/4 in (24.8 cm)
- 9 7/8 in (25.1 cm)
- 10 in (25.4 cm)
- 19 1/2 in (49.5 cm)
- 20 in (50.8 cm)
- 29 1/4 in (74.3 cm)
- 30 in (76.2 cm)
- 40 in (101.6 cm)
- Longer lengths up to 70 in may be available upon request.
Materials of Construction
- Filter Media: Polypropylene
- Adapters: Polypropylene
- Elastomer: Buna, EPDM, Silicone, Viton¹ (trademark), Santoprene² (licensed, flat gasket only)
Operating limits
- Maximum pressure drop: 35 psid (2.4 bar) @ 77°F (25°C)
- Recommended change-out pressure drop: 20 psid (1.4 bar) @ 77°F (25°C)
Certifications
- U.S. FDA 21CFR 177.1520 food contact requirements
- Article 3 of the EU Framework Regulation No. 1935/2004/EC safety requirements
- EU Plastics Regulation No. 10/2011 (may be used as intended in all compliant EU Member states)
- USP class VI-121°C Plastics criteria
- NSF 61 criteria
- ISO 9001 criteria
Efficiency Information
Table 2 in the official PDF provides removal efficiency based on a modified ASTM 795 test procedure, showing removal ratings (µm) at 90.0%, 99.0%, and 99.9% efficiencies for 1 µm and 5 µm filters. See the official PDF for exact tabulated values.
Clean Water Flow Rate
Graph 1 in the official PDF illustrates the clean water flow rate based on a 10 in length filter for both 1 µm and 5 µm filters, showing differential pressure (psi, mbar) versus flow rate (gpm, lpm). See the official PDF for the graphical data.
Ordering Information
The ordering code structure is RO.Zs MICRON-LENGTH-END1-END2-ELASTOMER. Columns 3, 4, and 5 (End #1 Adapter, End #2 Adapter, Elastomer Material) are optional. Bulk packaging uses "-B".
- Type: RO.Zs
- Micron Rating (nominal):
- 01 = 1 µm
- 05 = 5 µm
- Cartridge Length:
- 9 3/4 in (24.8 cm)
- 9 7/8 in (25.1 cm)
- 10 in (25.4 cm)
- 19 1/2 in (49.5 cm)
- 20 in (50.8 cm)
- 29 1/4 in (74.3 cm)
- 30 in (76.2 cm)
- 40 in (101.6 cm)
- Longer lengths up to 70 in may be available upon request.
- End #1 Adapter:
- E = 222 O-Ring
- F = 226 O-Ring
- L = Extended Core
- X = Standard Plain End (no gasket)
- Y = Flat Gasket
- H = Fin
- K = Self Seal Spring
- S = Solid End
- End #2 Adapter:
- X = Standard Plain End (no gasket)
- Y = Flat Gasket
- Elastomer Material:
- B = Buna
- E = EPDM
- P = Santoprene² (flat gasket only)
- S = Silicone
- V = Viton¹
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions present in the complete OEM PDF datasheet. For contractual data and precise specifications, the official OEM PDF revision used on the project must be consulted.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.