Back to Eaton filterbags
EFLogo pending

Datasheet summary

Eaton FlowLine FBF-0102-BD10-050D

Engineering summary from PDF text extraction for Eaton FlowLine FBF-0102-BD10-050D. Verify every value with the OEM datasheet.

Summary

Product identification

  • Bag Filter: FLOWLINE FBF-0102-BD10-050D
  • Code number: F610583

Operating limits

  • Max. theoretic flow rate: 40 m³/h (dependent on filter element / fluid)
  • Max. allowable pressure (PS): 10 bar
  • Min./max. allowable Temperature (TS): 120 °C

Mechanical / hydraulic

  • Filter area: 0,50 m²
  • Number of restrainer baskets: 1 qty
  • Filter housing volume (V): approx. 27 liter
  • Filter housing weight: approx. 27 kg
  • Installation height: approx. 1820 mm
  • Installation space: approx. 500 x 500 mm
  • Design code: AD 2000-Merkblätter
  • PED 97/23/EC classification: Art. 3 § 3

Materials of construction

  • Housing (lid, main flange): Stainless Steel CF8M
  • All other wetted parts: Stainless Steel 304
  • Restrainer basket: Stainless Steel 304
  • Closure (swing eyebolts): Carbon Steel Zinc plated
  • Other parts (non wetted): Stainless Steel SS 304
  • Gasket: NBR
  • Restrainer basket gasket: FPM

Housing connections

  • N1/N2 (inlet/ outlet): DN 50 PN 16 (DIN flange)
  • N3 (lid hole): G ¼“ female thread DIN ISO 228-1 without plug

Packing

  • Dimensions (L x W x H): 1190 x 360 x 300 mm

Spare parts

  • Restrainer basket: BKT-AS-BB-02
  • Bag fixing ring: 1x BFR-110-AC-01
  • NBR lid gasket: 1x OR-FBF-B-C01
  • FPM-Restrainer basket gasket: 1x P-EBF-V-B01
  • Swing Eyebolts: 4x EBS-M16-ZA-65

Accessories (optional)

  • Mesh strainers (25 - 800 µm): FMB-AS-AC-02(-25–800)
  • Evacuation balloon: BAL-SE-AC-02
  • Bag positioner: BLK-SE-AC-02
  • LOFNETIC magnetic insert: LOFNET-1BAR/2BAR-02
  • Wall mounting brackets: WMB-EBF-BB-01
  • Leg assembly: LAY-EBF-BB-01
  • Pressure gauge (10 bar) G ¼“: M-10-S
  • Vent valve G¼“: E-1/4-S
  • Pipe enlarging module DN50/DN65: RV-050/065D-AC
  • Gaskets available in: FPM, EPDM

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original PDF datasheet. For contractual data, always refer to the specific OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.