Eaton FlowLine FBF-0101-BD10-050D

Engineering summary from PDF text extraction for Eaton FlowLine FBF-0101-BD10-050D. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product Name: Bag Filter FLOWLINE FBF-0101-BD10-050D
  • Code number: F610582

Operating limits

  • Max. allowable pressure (PS): 10 bar
  • Min./max. allowable Temp. (TS): 120 °C
  • Design code: AD 2000-Merkblätter, PED 97/23/EC classification Art. 3 § 3

Mechanical / hydraulic

  • Max. theoretic flow rate: 20 m³/h (dependent on filter element / fluid)
  • Filter area: 0,25 m²
  • Number of restrainer baskets: 1
  • Filter housing volume (V): approx. 15,5 liter
  • Filter housing weight: approx. 21,5 kg
  • Installation height: approx. 1040 mm
  • Installation space: approx. 500 x 500 mm
  • Housing connections:
    • N1/N2 (inlet/ outlet): DN 50 PN 16 (DIN flange)
    • N3 (lid hole): G ¼“ female thread DIN ISO 228-1 without plug
  • Packing dimensions (L x W x H): 790 x 360 x 300 mm

Material of construction

  • Housing (lid, main flange): Stainless Steel CF8M
  • For all other wetted parts: Stainless Steel 304
  • Restrainer basket: Stainless Steel 304
  • Closure (Swing eyebolts): Carbon Steel Zinc plated
  • Other parts (non wetted): Stainless Steel 304
  • Gasket: NBR
  • Restrainer basket gasket: FPM

Spare parts

  • Restrainer basket: BKT-AS-BB-01
  • Bag fixing ring: 1x BFR-110-AC-01
  • NBR lid gasket: 1x OR-FBF-B-C01
  • FPM-Restrainer basket gasket: 1x P-EBF-V-B01
  • Swing eyebolts: 4x EBS-M16-ZA-65

Accessories (optional)

  • Mesh strainers (25 - 800 µm): FMB-AS-AC-01(-25–800)
  • Evacuation balloon: BAL-SE-AC-01
  • Bag positioner: BLK-SE-AC-01
  • LOFNETIC magnetic insert: LOFNET-1BAR/2BAR-01
  • Wall mounting brackets: WMB-EBF-BB-01
  • Leg assembly: LAY-EBF-BB-01
  • Pressure gauge (10 bar): G ¼“ M-10-S
  • Vent valve G¼“: E-1/4-S
  • Pipe enlarging module DN50/DN65: RV-050/065D-AC
  • Gaskets available in: FPM, EPDM

Disclaimer: This summary is based solely on the provided text extract. It may not include all figures, footnotes, or the latest revisions present in the official PDF datasheet. For contractual data, always refer to the specific OEM PDF revision used on the project.