Datasheet summary
Beco Membran PF Plus
Engineering summary from PDF text extraction for Beco Membran PF Plus. Verify every value with the OEM datasheet.
Summary
Product identification
The BECO MEMBRAN PFplus is a membrane filter cartridge specifically developed for the beverage industry as a final sterile end filter prior to bottling. It is designed for use after pre-filtration (e.g., using BECO depth filter sheets or pre-filter cartridges).
- Pore sizes:
- 0.22 µm (KVBL range for bacteria retention)
- 0.45 µm (KVBB range for bacteria retention)
- 0.65 µm (KVBY range for yeast retention)
- 1.0 µm (KVBA range for yeast retention)
- Materials:
- Pleated, hydrophilic polyvinylidenefluoride (PVDF) membranes
- Inside and outside support corpus and end caps made of polypropylene
- Silicone O-rings
Operating limits
- Maximum differential pressure (in direction of flow):
- 5.50 bar at 125 °C
- 1.70 bar at 180 °C
- 0.35 bar at 121 °C
- Maximum differential pressure (against flow direction): 3.5 bar at 25 °C (intermittent)
- Maximum operating temperature: 80 °C
- Resistance to hot water rinsing: Up to 95 °C
- Sterilization:
- Max temperature of 95 °C (hot water)
- Saturated steam at a max temperature of 109 °C for a period of 20 minutes (after steam has emerged from all openings and valves)
- Chemical resistance: Wide resistance (< pH 12) to common cleaning agents
Feed water
- For rinsing and sterilization, the water should be decalcified and filtered (1 µm).
Product water
The filter cartridges guarantee reliable filtration of yeast and bacteria.
- Retention efficiency:
- KVBL 0.22 µm: ≥ 10⁷ Pseudomonas aeruginosa and E. Coli
- KVBB 0.45 µm: ≥ 10⁷ Lactobacillus hilgardii, Oenococcus oeni
- KVBY 0.65 µm: ≥ 10⁷ Saccharomyces cerevisiae
- KVBA 1.0 µm: ≥ 10⁶ Saccharomyces cerevisiae
Mechanical / hydraulic
- Outer diameter: 69 mm
- Standard lengths: 25 cm/10", 50 cm/20", 75 cm/30" (100 cm/40" available on request)
- Filtration surface: 0.78 m² per 25 cm/10" element
- Integrity test (Max. diffusion rate per 25 cm element):
- 0.22 µm: 15.2 ml/min at 2.8 bar test pressure
- 0.45 µm: 17.1 ml/min at 1.5 bar test pressure
- 0.65 µm: 9.1 ml/min at 0.6 bar test pressure
- 1.00 µm: 6.3 ml/min at 0.5 bar test pressure
- Adapters:
- Code 0: Closed flat cap without centering tip
- Code 5: Double O-ring (2-222)
- Code 7: Double O-ring (2-226) quarter turn fastener
- Closed flat cap with centering tip for Code 5 and 7
- Gasket: Silicone (A)
- Flow Rates: Water flow rates for a 75 cm/30" element at 25 °C are shown graphically in the datasheet. See the official PDF for exact tabulated values.
Disclaimer: This summary is based on the provided text extraction and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.