General
9 models in this family. Representative models: HYDRAcap, HYDRAcap-40, HYDRAcap-40-LD.

ملف علامة دولية
Hydranautics is a Nitto Group membrane company with roots going back to 1963, reverse-osmosis membrane work beginning in 1970, and Nitto Denko ownership from 1987.In water-treatment procurement it is treated as a long-established membrane technology house, not just a model label: the brand is associated with RO, NF, UF, MF, and specialty membranes for desalination, reuse, high-purity water, and process separation.
Hydranautics UF Modules's position in ultrafiltration modules is defined by product families such as hollow-fiber, capillary, submerged, pressurized, and MBR-related UF membrane modules.The portfolio is best understood inside pretreatment, reuse, drinking water clarification, MBR solids separation, turbidity control, and pathogen barrier service, where engineers compare the technology route, family boundaries, and duty fit before narrowing to individual models.
Representative series on this page include HYDRAcap, HYDRAcap-40 and HYDRAcap-40-LD.Selection should focus on membrane material, pore size or MWCO, flux, cleaning method, module format, and skid layout.
9
Indexed models
1
Product families
0
Subgroups
خطوط المنتجات ودليل الاختيار
يجيب هذا القسم عن سؤالين: ما خطوط المنتجات الرئيسية لدى Hydranautics UF، وما المعايير التي يجب مقارنتها قبل اختيار الطراز المحدد.
تشمل خطوط المنتجات الرئيسية في هذه الصفحة General. ابدأ بهدف المعالجة وشكل المعدة وظروف التشغيل، ثم استخدم فهرس الطرازات أدناه لمقارنة المواصفات التفصيلية.
بعد اختيار خط المنتج، قارن module format, flux target, backwash strategy, and chemical tolerance. كما يجب في مشاريع الاستبدال التحقق من شروط التركيب والواجهات والتوافق مع النظام القائم، وفي المشاريع الجديدة مراعاة التشغيل والصيانة وتوفر قطع الغيار أو المواد الاستهلاكية.
1 product family on this page.
General
9 models in this family. Representative models: HYDRAcap, HYDRAcap-40, HYDRAcap-40-LD.
Quick Model Index
Search models, families, applications, or parameters; compare 2–4 candidates, save or export the shortlist, and open it on another device by link or QR code.
Showing 9 of 9 models
Select 2–4 models to compare. Your shortlist is saved on this device and can travel by link or QR code.
HYDRAcap
General
Maximum Feed Pressure: 73 psig (5 bar) · Transmembrane Pressure (TMP) range: 4 - 22 psig (27 - 152 kPa) · Backwash Pressure: 35 psig (242 kPa)
The HYDRAcap is an ultrafiltration module featuring capillary technology with a hydrophilic polyethersulfone membrane. It offers high filtrate quality.
HYDRAcap-40
General
Filtrate Flow: 7.7 – 18.9 gpm (1.8 – 4.3 m³/h) · Nominal Membrane Area: 320 ft² (30 m²) · Pore size: 0.02 micron
The HYDRAcap-40 is a capillary ultrafiltration module utilizing hydrophilic polyethersulfone membrane for inside-to-outside filtration.
HYDRAcap-40-LD
General
Filtrate Flow: 5 – 12.3 gpm (1.1 – 2.8 m³/h) · Pore size: 0.02 micron · Nominal Membrane Area: 208 ft² (19.3 m²)
The HYDRAcap-40-LD is a capillary ultrafiltration module featuring a hydrophilic polyethersulfone membrane with a 0.02-micron pore size.
HYDRAcap-MAX-40
General
Filtrate Flow: 7.5 – 24.4 gpm (1.7 – 5.5 m³/h) · Nominal Membrane Area: 560 ft² (52 m²) · Pore size: 0.1 micron
The HYDRAcap-MAX-40 is a capillary microfiltration module with a PVDF membrane offering 560 ft² of nominal area for outside-to-inside filtration.
HYDRAcap-60
General
Filtrate Flow: 12.1 – 29.5 gpm (2.7 – 6.7 m³/h) · Nominal Membrane Area: 500 ft² (46 m²) · Pore size: 0.02 micron
The HYDRAcap-60 is a capillary ultrafiltration module constructed with hydrophilic polyethersulfone membrane polymer. It operates with inside-to-outside filtration.
HYDRAcap-60-LD
General
Retention / pore size: 0.02 micron · Filtrate Flow: 7.8 – 19 gpm (1.8 – 4.3 m³/h) · Pore size: 0.02 micron
The HYDRAcap-60-LD is a capillary ultrafiltration module utilizing a hydrophilic polyethersulfone membrane with a 0.02 micron pore size.
HYDRAcap-MAX-60
General
Filtrate Flow: 11.7 – 37.9 gpm (2.7 – 8.6 m³/h) · Nominal Membrane Area: 840 ft² (78 m²) · Pore Size: 0.1 micron
The HYDRAcap-MAX-60 is a capillary microfiltration module utilizing PVDF membrane polymer for outside-to-inside filtration.
HYDRAcap-80
General
Filtrate Flow: 16.3 – 39.5 gpm (3.7 – 9.0 m³/h) · Nominal Membrane Area: 670 ft² (62.2 m²) · Maximum Applied Feed Pressure: 73 psig (5 bar)
The HYDRAcap-80 is a capillary ultrafiltration module with a hydrophilic polyethersulfone membrane, suitable for inside-to-outside filtration.
HYDRAcap-MAX-80
General
Filtrate Flow: 15.7 – 51.0 gpm (3.6 – 11.6 m³/h) (Typical module performance for most feedwaters) · Nominal Membrane Area: 1130 ft² (105 m²) · Pore size: 0.08 micron
The HYDRAcap-MAX-80 is a capillary ultrafiltration module featuring a TIPS PVDF membrane with a nominal area of 1130 ft².
Brand Products & Technical Documents
Each card keeps the curated model introduction and combines the readable datasheet page, OEM PDF, and official source. Product understanding and document access now share one card set.
9 product profiles
Product profile
The HYDRAcap is an ultrafiltration module featuring capillary technology with a hydrophilic polyethersulfone membrane. It offers high filtrate quality.
Product profile
The HYDRAcap-40 is a capillary ultrafiltration module utilizing hydrophilic polyethersulfone membrane for inside-to-outside filtration.
Product profile
The HYDRAcap-40-LD is a capillary ultrafiltration module featuring a hydrophilic polyethersulfone membrane with a 0.02-micron pore size.
Product profile
The HYDRAcap-MAX-40 is a capillary microfiltration module with a PVDF membrane offering 560 ft² of nominal area for outside-to-inside filtration.
Product profile
The HYDRAcap-60 is a capillary ultrafiltration module constructed with hydrophilic polyethersulfone membrane polymer. It operates with inside-to-outside filtration.
Product profile
The HYDRAcap-60-LD is a capillary ultrafiltration module utilizing a hydrophilic polyethersulfone membrane with a 0.02 micron pore size.
Product profile
The HYDRAcap-MAX-60 is a capillary microfiltration module utilizing PVDF membrane polymer for outside-to-inside filtration.
Product profile
The HYDRAcap-80 is a capillary ultrafiltration module with a hydrophilic polyethersulfone membrane, suitable for inside-to-outside filtration.
Product profile
The HYDRAcap-MAX-80 is a capillary ultrafiltration module featuring a TIPS PVDF membrane with a nominal area of 1130 ft².