Debubbling
5 models in this family. Representative models: MM Series 0.5 x 1, MM Series 0.75 x 1, MM Series 1.7 x 5.5.
ملف علامة دولية
3M Liqui-Cel and Liqui-Flux records should be read as 3M membrane contactor and membrane-filtration technologies.Liqui-Cel is used for dissolved gas control such as degassing and carbonation management, while Liqui-Flux UF modules support filtration duties where compact membrane modules and established 3M component supply are useful.
3M-Liqui-Cel® Membrane Contactors's position in RO/NF membranes and related equipment is defined by product families such as Debubbling, Gas transfer, Degassing (low surface tension fluids) and Application / guidance.
The portfolio is best understood inside brackish water, seawater desalination, ultrapure water, process separation, reuse, degassing, and membrane system packaging, where engineers compare the technology route, family boundaries, and duty fit before narrowing to individual models.Representative series on this page include MM Series 0.5 x 1, MM Series 0.75 x 1 and MM Series 1.7 x 5.5.Engineers should compare element size, salt rejection, permeate flow, pressure rating, fouling resistance, connection type, and vessel fit.
30
Indexed models
4
Product families
0
Subgroups
خطوط المنتجات ودليل الاختيار
يجيب هذا القسم عن سؤالين: ما خطوط المنتجات الرئيسية لدى 3M-Liqui-Cel® Contactors، وما المعايير التي يجب مقارنتها قبل اختيار الطراز المحدد.
تشمل خطوط المنتجات الرئيسية في هذه الصفحة Debubbling, Gas transfer, Degassing (low surface tension fluids), and Application / guidance. ابدأ بهدف المعالجة وشكل المعدة وظروف التشغيل، ثم استخدم فهرس الطرازات أدناه لمقارنة المواصفات التفصيلية.
بعد اختيار خط المنتج، قارن pressure rating, element count, port layout, and code requirement. كما يجب في مشاريع الاستبدال التحقق من شروط التركيب والواجهات والتوافق مع النظام القائم، وفي المشاريع الجديدة مراعاة التشغيل والصيانة وتوفر قطع الغيار أو المواد الاستهلاكية.
4 product familys on this page.
Debubbling
5 models in this family. Representative models: MM Series 0.5 x 1, MM Series 0.75 x 1, MM Series 1.7 x 5.5.
Gas transfer
13 models in this family. Representative models: EXF Series 2.5 x 8, EXF Series 4 x 13, EXF Series 4 x 28.
Degassing (low surface tension fluids)
6 models in this family. Representative models: SP Series 0.5 x 1, SP Series 1 x 3, SP Series 2 x 6.
Application / guidance
6 models in this family. Representative models: 3M Liqui-Cel General brochure, 3M liqui-Cel Inlet & sweep gas guideline, 3M Liqui-Cel cleaning & storage.
Quick Model Index
Search models, families, applications, or parameters; compare 2–4 candidates, save or export the shortlist, and open it on another device by link or QR code.
Showing 30 of 30 models
Select 2–4 models to compare. Your shortlist is saved on this device and can travel by link or QR code.
MM Series 0.5 x 1
Debubbling
Liquid Flow Guidelines: 5 – 30 ml/min (Liquid must flow on the shellside) · Weight (approximate) - Dry: 10 grams · Membrane/Potting Material: Polypropylene / Epoxy
The 3M™ Liqui-Cel™ MM-0.5x1 Series is a membrane contactor designed for gas transfer applications.
MM Series 0.75 x 1
Debubbling
Liquid Flow Guidelines: 15 - 200 ml/min · Maximum Shellside LIQUID Working Temperature/Pressure: 5-25°C, 3.1 barg (41-77°F, 45 psig) · Membrane/Potting Material: Polypropylene / Epoxy
This 3M™ Liqui-Cel™ MM-0.75x1 Series Membrane Contactor features a no baffle disc design with X40 fiber membrane material.
MM Series 1.7 x 5.5
Debubbling
Liquid Flow Guidelines: <2500 ml/min · Nominal diameter: 43 mm (1.7 in) · Nominal length: 182 mm (7.2 in) or 114 mm (4.5 in) – See the official PDF for exact dimensions and specific orientations
The 3M™ Liqui-Cel™ MM-1.7x5.5 Series Membrane Contactor is designed for gas or vacuum transfer applications with a polycarbonate housing.
MM Series 1.7 x 8.75
Debubbling
Weight (approximate): 186 grams (dry) · Membrane/Potting Material: Polypropylene/Polyurethane · Housing Material: Polycarbonate
The 3M™ Liqui-Cel™ MM-1.7x8.75 Series is a membrane contactor designed for degassing liquids. It features a parallel flow.
MM Series 1.7 x 10
Debubbling
Liquid Flow Guidelines: <2000 ml/min · Maximum Lumenside LIQUID Working Temperature/Pressure: 5-20°C, 8 barg · Maximum Applied Shellside Gas Temperature/Pressure: 20°C, 6 barg
The 3M™ Liqui-Cel™ MM-1.7x10 Series Membrane Contactor is designed for gasification and degassing applications.
EXF Series 2.5 x 8
Gas transfer
Maximum Applied Gas Pressure: 4.8 barg at 25°C (70 psig at 77°F) (This is for integrity testing; normal operating pressures are typically lower.) · Overall length: 254 mm (10.0 in) or 277 mm (10.9 in) depending on orientation · Diameter: 67 mm (2.6 in) to 77 mm (3.1 in)
The 3M-Liqui-Cel EXF-2.5x8 is a membrane contactor designed for gas removal from liquids.
EXF Series 4 x 13
Gas transfer
Liquid Flow Guidelines: 0.5–3.4 m³/hr (2–15 gpm) · Overall length: 512 mm (20.1 in) · Diameter: 116 mm (4.6 in)
The 3M™ Liqui-Cel™ EXF-4x13 is an Extra-Flow membrane contactor designed for gas transfer applications in water treatment.
EXF Series 4 x 28
Gas transfer
Liquid Flow Guidelines: 0.9 – 6.8 m³/hr (4 – 30 gpm) · Overall Length: 889 mm (35.0 in) · Diameter (main): 116 mm (4.6 in)
The 3M™ Liqui-Cel™ EXF-4x28 is an Extra-Flow membrane contactor designed for gas transfer applications.
EXF Series 6 x 28
Gas transfer
Liquid Flow Guidelines: 1 – 11 m³/hr (5 – 50 gpm) · Maximum Applied Gas Pressure: 4.1 barg at 25°C (60 psig at 77°F) · Membrane/Potting Material: Polypropylene/Epoxy
The 3M™ Liqui-Cel™ EXF-6x28 Series is a membrane contactor available with X50 fiber for CO₂ removal or X40 fiber for O₂ removal.
EXF Series 8 x 20
Gas transfer
Liquid Flow Guidelines: 1 – 11 m³/hr (5 – 50 gpm) · Maximum Applied Gas Pressure: 5.2 barg at 25°C (75 psig at 77°F) · Housing Material: 316L SS Housing, ABS Cartridge Shell
The 3M™ Liqui-Cel™ EXF-8x20 Series is a membrane contactor recommended for gas transfer applications, including oxygen and carbon dioxide removal.
EXF Series 8 x 20 Stainless steel housing
Gas transfer
Liquid Flow Guidelines: 1 – 11 m³/hr (5 – 50 gpm) · Maximum Applied Gas Pressure: 2.1 barg at 25°C (30 psig at 77°F) (for integrity testing at ambient temperatures; normal operating pressures are typically lower) · Pressure Guideline: Liquid pressure should always exceed gas pressure
The 3M™ Liqui-Cel™ EXF-8x20 is an industrial series membrane contactor designed for CO₂ removal and other gas transfer applications.
EXF Series 8 x 40
Gas transfer
Liquid Flow Rate: 7 – 28 m³/hr (30 – 125 gpm) · Maximum Applied Gas Pressure: 2.1 barg at 25°C (30 psig at 77°F) · Length: 1502 mm (59.2 in)
The 3M™ Liqui-Cel™ EXF-8x40 Series is an extra-flow membrane contactor with a center baffle, designed for high-pressure O₂ removal.
EXF Series 8 x 80
Gas transfer
Liquid Flow Guidelines: 7 – 28 m³/hr (30 – 125 gpm) · Maximum Applied Gas Pressure: 2.1 barg at 25°C (30 psig at 77°F) (for integrity testing at ambient temperatures; normal operating pressures are typically lower) · Overall Length: 2518 mm (99.2 in)
The 3M Liqui-Cel EXF-8x80 Series is a membrane contactor designed for high-pressure gas transfer applications like O₂ removal.
EXF Series 8 x 40/8 x 80 cartridge
Gas transfer
Weight (Dry, approximate): 11 kg (25 lbs) · Cartridge Shell and Center Tube Material: ABS · End Cap Adapter and Inner Connector Material: ABS
The EXF Series 8 x 40/8 x 80 cartridge is a membrane contactor designed for high-pressure oxygen removal and other gas transfer applications.
EXF Series 10 x 28
Gas transfer
Liquid Flow Guidelines: 10 – 57 m³/hr (44 – 250 gpm) · Pressure Limits Basis: Pressures are based on fluid group 2 (other) liquids and gases per the European Union Pressure Equipment Directive 2014/68/EU · Membrane/Potting Material: Polypropylene / Epoxy
The 3M-Liqui-Cel® EXF-10x28 Series Membrane Contactor is designed for gas transfer applications like CO₂ or O₂ removal from liquids.
EXF Series 10 x 28
Gas transfer
Liquid Flow Guidelines: 10 – 48 m³/hr (44 – 210 gpm) · Maximum Shellside LIQUID Working Temperature/Pressure: 5-50°C, 4.1 barg (41-122°F, 60 psig) · Maximum Applied Gas Pressure: 4.1 barg at 25°C (60 psig at 77°F)
The 3M™ Liqui-Cel™ EXF-10x28 is an industrial series membrane contactor designed for liquid degassing applications.
EXF Series 14 x 28
Gas transfer
Liquid Flow Guidelines: 16 – 91 m³/hr (70 – 400 gpm) · Maximum Applied Gas Pressure: 4.1 barg at 25°C (60 psig at 77°F) · Overall length (with Nylon End Caps): 1156 mm (45.5 in)
The 3M Liqui-Cel EXF-14x28 Series Membrane Contactor is designed for gas transfer applications, featuring an Extra-Flow with Center Baffle cartridge.
EXF Series 14 x 40
Gas transfer
Liquid Flow Guidelines: 16 – 125 m³/hr (70 – 550 gpm) · Maximum Applied Gas Pressure: 4.1 barg at 25°C (60 psig at 77°F) · Overall length with engineered thermoplastic end caps: 1466 mm (57.7 in)
The 3M™ Liqui-Cel™ EXF-14x40 Series is a membrane contactor designed for O₂ removal and other gas transfer applications.
SP Series 0.5 x 1
Degassing (low surface tension fluids)
Liquid Flow Guidelines: 5 – 30 ml/min (Liquid must flow on the shellside) · Membrane/Potting Material: Polyolefin / Epoxy · Material: Black Polyethylene
The 3M-Liqui-Cel SP-0.5x1 Series is a membrane contactor designed for gas transfer applications.
SP Series 1 x 3
Degassing (low surface tension fluids)
Liquid Flow Guidelines: 15 - 60 ml/min (Liquid must flow on the shellside) · Typical Membrane Surface Area: 294 cm² · Membrane/Potting Material: Polyolefin / Polyethylene
The SP Series 1x3 is a membrane contactor designed for degasification of low surface tension liquids.
SP Series 2 x 6
Degassing (low surface tension fluids)
Liquid Flow Guidelines: 100 ml/min – 1 liter/min (Liquid must flow on the shellside) · Overall Length: 143 mm (5.6 in) · Diameter: 56 mm (2.2 in)
The 3M™ Liqui-Cel™ SP-2x6 Series is a membrane contactor for gas/liquid contacting applications. It features a no baffle radial flow cartridge configuration.
SP Series 2.5 x 8
Degassing (low surface tension fluids)
Liquid Flow Guidelines (Shellside): 0.1 – 0.7 m³/hr (0.5 – 3 gpm) · Oxygen Removal % vs. Water Flow Rate: Shows the percentage of oxygen removal relative to water flow rate (in m³/hr and gpm) at different vacuum levels (50 torr, 75 torr) · Maximum Applied Gas Pressure: 4.1 barg at 25°C (60 psig at 77°F)
The 3M™ Liqui-Cel™ SP-2.5x8 Series is a membrane contactor designed for liquid degassing and gas transfer applications.
SP Series 4 x 13
Degassing (low surface tension fluids)
Liquid Flow Guidelines: 0.2 – 3.4 m³/hr (1–15 gpm) · Maximum Applied Gas Pressure: 4.1 barg at 25°C (60 psig at 77°F) · Nominal Dimensions (Polypropylene housing): 116 mm (4.6 in), 85 mm (3.3 in), 413.6 mm (16.3 in). See full housing drawing on 3M.com/Liqui-Cel for additional details
The SP Series 4x13 is an Extra-Flow membrane contactor with a center baffle, constructed with a polypropylene housing and polyolefin membrane.
SP Series 4 x 28
Degassing (low surface tension fluids)
Liquid Flow Guidelines: 1.1-6.8 m³/hr (5-30 gpm) · Maximum Applied Gas Pressure: 4.1 barg at 25°C (60 psig at 77°F) · Material: Polypropylene, 316L SS (32 Ra finish)
The 3M-Liqui-Cel SP Series 4x28 is a membrane contactor designed for degassing and gas transfer applications, available with fluoroelastomer or perfluoroelastomer seals.
3M Liqui-Cel General brochure
Application / guidance
Transverse flow: Liquid flows into the liquid inlet, crosses the hollow fibers, and then exits through the opposite port. No baffle is used. A vacuum or strip gas can be applied to either gas port · Radial flow: A plugged center tube on one side forces liquid radially over the hollow fibers. Primarily used for degassing low surface tension fluids · Extra-flow in high pressure vessel: An RO-style vessel generates a much higher maximum pressure. Liquid is directed radially across the membrane array by a baffle
3M™ Liqui-Cel™ Membrane Contactors are gas transfer devices that use microporous hollow fiber membranes to remove, add, or control dissolved gases in liquids.
3M liqui-Cel Inlet & sweep gas guideline
Application / guidance
Selection cues: housing diameter · pressure rating · port format and element count
This document provides guidelines for inlet water and sweep gas quality for 3M™ Liqui-Cel™ Membrane Contactors.
3M Liqui-Cel cleaning & storage
Application / guidance
Water pressure: Max 2 bar (29 psi) · Water temperature: Max 85°C (185°F) · Chlorine: 100 ppm for 15 min (Once/month). Use Hypochlorite at high pH only; avoid Chlorine Dioxide
These 3M Liqui-Cel EXF Series membrane contactors are designed for removing or adding dissolved gases and bubbles to compatible liquids in industrial and food and...
3M Liqui-Cel operating manual
Application / guidance
Cleaning Pressure Differential: For 2.5x8-inch, 4-inch, and 10-inch membrane contactors, lumen side pressure should never exceed shell side pressure during cleaning · High Pressure: Similar to Extra-Flow but with a different housing concept for high-pressure applications (e.g., 8 x 40 and 8 x 80-inch contactors) · Power Supply: Always use a grounded power supply of the appropriate voltage matching the system’s vacuum pump or blower voltage, with 15 amp fuse protection and a local disconnect switch
The 3M™ Liqui-Cel™ Extra-Flow Membrane Contactors are designed to add or remove dissolved gases from liquid streams using microporous polypropylene hollow fibers.
3M Liqui-Cel membrane contactor power plant thailand
Application / guidance
Membrane Pore Size: 0.03 µm · Pressure: 1.6 bar min · pH: 6.5-8
This 3M Liqui-Cel membrane contactor is designed for CO₂ removal in power plant applications, operating downstream of a double-pass RO system.
Brand Products & Technical Documents
Each card keeps the curated model introduction and combines the readable datasheet page, OEM PDF, and official source. Product understanding and document access now share one card set.
5 product profiles
Product profile
The 3M™ Liqui-Cel™ MM-0.5x1 Series is a membrane contactor designed for gas transfer applications.
Product profile
This 3M™ Liqui-Cel™ MM-0.75x1 Series Membrane Contactor features a no baffle disc design with X40 fiber membrane material.
Product profile
The 3M™ Liqui-Cel™ MM-1.7x5.5 Series Membrane Contactor is designed for gas or vacuum transfer applications with a polycarbonate housing.
Product profile
The 3M™ Liqui-Cel™ MM-1.7x8.75 Series is a membrane contactor designed for degassing liquids. It features a parallel flow.
Product profile
The 3M™ Liqui-Cel™ MM-1.7x10 Series Membrane Contactor is designed for gasification and degassing applications.
13 product profiles
Product profile
The 3M-Liqui-Cel EXF-2.5x8 is a membrane contactor designed for gas removal from liquids.
Product profile
The 3M™ Liqui-Cel™ EXF-4x13 is an Extra-Flow membrane contactor designed for gas transfer applications in water treatment.
Product profile
The 3M™ Liqui-Cel™ EXF-4x28 is an Extra-Flow membrane contactor designed for gas transfer applications.
Product profile
The 3M™ Liqui-Cel™ EXF-6x28 Series is a membrane contactor available with X50 fiber for CO₂ removal or X40 fiber for O₂ removal.
Product profile
The 3M™ Liqui-Cel™ EXF-8x20 Series is a membrane contactor recommended for gas transfer applications, including oxygen and carbon dioxide removal.
Product profile
The 3M™ Liqui-Cel™ EXF-8x20 is an industrial series membrane contactor designed for CO₂ removal and other gas transfer applications.
Product profile
The 3M™ Liqui-Cel™ EXF-8x40 Series is an extra-flow membrane contactor with a center baffle, designed for high-pressure O₂ removal.
Product profile
The 3M Liqui-Cel EXF-8x80 Series is a membrane contactor designed for high-pressure gas transfer applications like O₂ removal.
Product profile
The EXF Series 8 x 40/8 x 80 cartridge is a membrane contactor designed for high-pressure oxygen removal and other gas transfer applications.
Product profile
The 3M-Liqui-Cel® EXF-10x28 Series Membrane Contactor is designed for gas transfer applications like CO₂ or O₂ removal from liquids.
Product profile
The 3M™ Liqui-Cel™ EXF-10x28 is an industrial series membrane contactor designed for liquid degassing applications.
Product profile
The 3M Liqui-Cel EXF-14x28 Series Membrane Contactor is designed for gas transfer applications, featuring an Extra-Flow with Center Baffle cartridge.
Product profile
The 3M™ Liqui-Cel™ EXF-14x40 Series is a membrane contactor designed for O₂ removal and other gas transfer applications.
6 product profiles
Product profile
The 3M-Liqui-Cel SP-0.5x1 Series is a membrane contactor designed for gas transfer applications.
Product profile
The SP Series 1x3 is a membrane contactor designed for degasification of low surface tension liquids.
Product profile
The 3M™ Liqui-Cel™ SP-2x6 Series is a membrane contactor for gas/liquid contacting applications. It features a no baffle radial flow cartridge configuration.
Product profile
The 3M™ Liqui-Cel™ SP-2.5x8 Series is a membrane contactor designed for liquid degassing and gas transfer applications.
Product profile
The SP Series 4x13 is an Extra-Flow membrane contactor with a center baffle, constructed with a polypropylene housing and polyolefin membrane.
Product profile
The 3M-Liqui-Cel SP Series 4x28 is a membrane contactor designed for degassing and gas transfer applications, available with fluoroelastomer or perfluoroelastomer seals.
6 product profiles
Product profile
3M™ Liqui-Cel™ Membrane Contactors are gas transfer devices that use microporous hollow fiber membranes to remove, add, or control dissolved gases in liquids.
Product profile
This document provides guidelines for inlet water and sweep gas quality for 3M™ Liqui-Cel™ Membrane Contactors.
Product profile
These 3M Liqui-Cel EXF Series membrane contactors are designed for removing or adding dissolved gases and bubbles to compatible liquids in industrial and food and...
Product profile
The 3M™ Liqui-Cel™ Extra-Flow Membrane Contactors are designed to add or remove dissolved gases from liquid streams using microporous polypropylene hollow fibers.
Product profile
This 3M Liqui-Cel membrane contactor is designed for CO₂ removal in power plant applications, operating downstream of a double-pass RO system.
Product profile
This product provides guidelines for inlet water and sweep gas conditions for 3M™ Liqui-Cel™ Membrane Contactors. Recommended pre-treatment includes softening.