Coriolis flowmeters
35 models in this family. Representative models: Proline Cubemass C 300, Proline Cubemass C 500, Proline Promass A 100.

ملف علامة دولية
Endress+Hauser is a family-owned process instrumentation and automation group founded in 1953.Its influence in water and wastewater plants comes from a broad measurement portfolio - flow, level, pressure, temperature, and liquid analysis - plus calibration, diagnostics, and control-system integration for continuous process reliability.
Endress + Hauser Flow measurement's position in instrumentation and sensors is defined by product families such as Coriolis flowmeters, Electromagnetic flowmeters, Ultrasonic flowmeters and Thermal mass flowmeters.
The portfolio is best understood inside online water-quality measurement, process control, chemical dosing feedback, plant monitoring, and safety interlocks, where engineers compare the technology route, family boundaries, and duty fit before narrowing to individual models.Representative series on this page include Proline Cubemass C 300, Proline Cubemass C 500 and Proline Promass A 100.Engineers should compare measured parameter, range and accuracy, wetted materials, calibration workflow, and control-system communication.
77
Indexed models
6
Product families
0
Subgroups
خطوط المنتجات ودليل الاختيار
يجيب هذا القسم عن سؤالين: ما خطوط المنتجات الرئيسية لدى Endress + Hauser Flow measurement، وما المعايير التي يجب مقارنتها قبل اختيار الطراز المحدد.
تشمل خطوط المنتجات الرئيسية في هذه الصفحة Coriolis flowmeters, Electromagnetic flowmeters, Ultrasonic flowmeters, and Thermal mass flowmeters. ابدأ بهدف المعالجة وشكل المعدة وظروف التشغيل، ثم استخدم فهرس الطرازات أدناه لمقارنة المواصفات التفصيلية.
بعد اختيار خط المنتج، قارن measurement parameter, sample condition, signal integration, and maintenance frequency. كما يجب في مشاريع الاستبدال التحقق من شروط التركيب والواجهات والتوافق مع النظام القائم، وفي المشاريع الجديدة مراعاة التشغيل والصيانة وتوفر قطع الغيار أو المواد الاستهلاكية.
6 product familys on this page.
Coriolis flowmeters
35 models in this family. Representative models: Proline Cubemass C 300, Proline Cubemass C 500, Proline Promass A 100.
Electromagnetic flowmeters
22 models in this family. Representative models: Dosimag-5BH, Dosimag-D5AB, Dosimass-8BE.
Ultrasonic flowmeters
13 models in this family. Representative models: Proline Prosonic Flow E 100, Proline Prosonic Flow I 400, Proline Prosonic Flow W 400.
Thermal mass flowmeters
1 model in this family. Representative models: Flowphant-T-DTT31.
Vortex flowmeters
4 models in this family. Representative models: Proline Prowirl D 200, Proline Prowirl F 200, Proline Prowirl O 200.
Differential flow measurement
2 models in this family. Representative models: IFLRUN, IFLSKID.
Quick Model Index
Search models, families, applications, or parameters; compare 2–4 candidates, save or export the shortlist, and open it on another device by link or QR code.
Showing 77 of 77 models
Select 2–4 models to compare. Your shortlist is saved on this device and can travel by link or QR code.
Proline Cubemass C 300
Coriolis flowmeters
Nominal diameter range: DN 1 to 6 (¹⁄₂₄ to ¹⁄₄") · Measuring range: 0 to 1000 kg/h (0 to 37 lb/min) · Connection: 1.4539 (904L); 1.4404 (316/316L)
The Proline Cubemass C 300 is a compact Coriolis flowmeter designed for measuring small flow rates in skids, test rigs, and robotics.
Proline Cubemass C 500
Coriolis flowmeters
Medium temperature range: –50 to +205 °C (–58 to +401 °F) · Ambient temperature range (Standard): –40 to +60 °C (–40 to +140 °F) · Ambient temperature range (Option): –50 to +60 °C (–58 to +140 °F)
The Proline Cubemass C 500 is a compact Coriolis flowmeter designed for measuring the smallest flow rates in skids, test rigs, and industrial robotics.
Proline Promass A 100
Coriolis flowmeters
Medium temperature range: –50 to +205 °C (–58 to +401 °F) · Ambient temperature range (Standard): –40 to +60 °C (–40 to +140 °F) · Ambient temperature range (Option): –50 to +60 °C (–58 to +140 °F)
The Endress + Hauser Proline Promass A 100 is a compact Coriolis flowmeter designed for precise measurement of small liquid and gas quantities.
Proline Promass A 200
Coriolis flowmeters
Nominal diameter range: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈") · Medium temperature range: -50 to 205 °C (-58 to 401 °F) · Ambient temperature range: -40 to 60 °C (-40 to +140 °F)
The Proline Promass A 200 is a loop-powered Coriolis flowmeter designed for accurate measurement of lowest flow rates in demanding applications.
Proline Promass A 300
Coriolis flowmeters
Medium Temperature Range: -50 to 205 °C (-58 to 401 °F) · Ambient Temperature Range: -40 to 60 °C (-40 to +140 °F) · Nominal Diameter Range: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈")
The Endress+Hauser Proline Promass A 300 is a compact Coriolis flowmeter designed for continuous process control of liquids and gases.
Proline Promass A 500
Coriolis flowmeters
Medium temperature range: -50 to 205 °C (-58 to 401 °F) · Ambient temperature range: -40 to 60 °C (-40 to +140 °F) · Nominal diameter range: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈")
The Endress + Hauser Proline Promass A 500 is a compact Coriolis flowmeter designed for demanding applications.
Proline Promass E 100
Coriolis flowmeters
Measuring range: 0 to 180 000 kg/h (0 to 6600 lb/min) · Medium temperature range: –40 to +150 °C (–40 to +302°F) · Nominal diameter range: DN 8 to 80 (⅜ to 3")
The Proline Promass E 100 is a mid-range Coriolis flowmeter designed for accurate liquid and gas measurement in standard applications with an ultra-compact transmitter.
Proline Promass E 200
Coriolis flowmeters
Medium temperature range: –40 to +150 °C (–40 to +302 °F) · Ambient temperature range: –40 to +60 °C (–40 to +140 °F) · Nominal diameter range: DN 8 to 50 (⅜ to 2")
The Endress + Hauser Proline Promass E 200 is a Coriolis flowmeter designed for accurate liquid and gas measurement in standard chemical industry applications.
Proline Promass E 300
Coriolis flowmeters
Nominal diameter range: DN 8 to 80 (⅜ to 3") · Measuring range: 0 to 180 000 kg/h (0 to 6615 lb/min) · Medium temperature range: –40 to +150 °C (–40 to +302 °F)
The Endress + Hauser Proline Promass E 300 is a mid-range Coriolis flowmeter designed for accurate measurement of liquids and gases in standard applications.
Proline Promass E 500
Coriolis flowmeters
Measuring range: 0 to 180,000 kg/h (0 to 6615 lb/min) · Medium temperature range: –40 to +150 °C (–40 to +302 °F) · Nominal diameter range: DN 8 to 80 (⅜ to 3")
PDF datasheet mirror for Proline Promass E 500 (Endress + Hauser Flow measurement).
Proline Promass F 100
Coriolis flowmeters
Medium temperature range (Standard): –50 to +150 °C (–58 to +302 °F) · Medium temperature range (Option): –50 to +240 °C (–58…+464 °F) · Ambient temperature range (Standard): –40 to +60 °C (–40 to +140 °F)
The Proline Promass F 100 is an ultra-compact Coriolis flowmeter designed for precise measurement of mass flow, density, and temperature.
Proline Promass F 200
Coriolis flowmeters
Medium temperature range (Standard): –50 to +150 °C (–58 to +302 °F) · Medium temperature range (Option): –50 to +205 °C (–58 to +401 °F) · Ambient temperature range: –40 to +60 °C (–40 to +140 °F)
The Proline Promass F 200 is a robust Coriolis flowmeter offering high measurement performance for liquids and gases across various applications.
Proline Promass F 300
Coriolis flowmeters
Medium temperature range (Standard): –50 to +150 °C (–58 to +302 °F) · Medium temperature range (Option): –50 to +240 °C (–58 to +464 °F) · Medium temperature range (High temp option): –50 to +350 °C (–58 to +662 °F)
The Proline Promass F 300 is a Coriolis flowmeter offering premium accuracy and robustness for mass and volume flow measurement.
Proline Promass F 500
Coriolis flowmeters
Nominal diameter range: DN 8 to 250 (⅜ to 10") · Measuring range: 0 to 2 200 000 kg/h (0 to 80 840 lb/min) · Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022); 1.4301 (F304)
The Proline Promass F 500 is a high-accuracy Coriolis flowmeter for demanding liquid and gas applications, featuring integrated Heartbeat Technology for reliability.
Proline Promass G 100
Coriolis flowmeters
Medium Temperature Range: –50 to +150 °C (–58 to +302 °F) · Ambient Temperature Range: –40 to +60 °C (–40 to +140 °F) · Optional Ambient Temperature Range: –50 to +60 °C (–58 to +140 °F)
The Endress + Hauser Proline Promass G 100 is a compact Coriolis flowmeter designed for accurate measurement of liquids and gases in high-pressure applications.
Proline Promass H 100
Coriolis flowmeters
Measuring range: 0 to 70 000 kg/h (0 to 2570 lb/min) · Nominal diameter range: DN 8 to 50 (³⁄₈ to 2") · Connection: Tantalum; 702 (UNS R60702)
The Proline Promass H 100 is a chemically resistant Coriolis flowmeter with an ultra-compact transmitter, designed for aggressive fluids in space-constrained applications.
Proline Promass H 300
Coriolis flowmeters
Measuring range: 0 to 70 000 kg/h (0 to 2570 lb/min) · Nominal diameter range: DN 8 to 50 (³⁄₈ to 2") · Connection: Tantalum; 702 (UNS R60702)
The Proline Promass H 300 is a highly accurate, chemically resistant Coriolis flowmeter designed for aggressive fluids.
Proline Promass H 500
Coriolis flowmeters
Connection: Tantalum; 702 (UNS R60702) · Nominal diameter: DN 8 to 50 (³⁄₈ to 2") · Mass flow (liquid): ±0.10 %
The Proline Promass H 500 is a remote version Coriolis flowmeter designed for aggressive fluids requiring highest corrosion resistance and accuracy.
Proline Promass I 100
Coriolis flowmeters
Measuring range: 0 to 180 000 kg/h (0 to 6600 lb/min) · Medium temperature range: –50 to +150 °C (–58 to +302 °F) · Nominal diameter range: DN 8 to 80 (⅜ to 3")
The Endress + Hauser Proline Promass I 100 is an ultra-compact Coriolis flowmeter designed for measuring liquids and gases with minimal pressure loss.
Proline Promass I 300
Coriolis flowmeters
Medium temperature range: –50 to +150 °C (–58 to +302 °F) · Ambient temperature range (Standard): –40 to +60 °C (–40 to +140 °F) · Ambient temperature range (Option): –50 to +60 °C (–58 to +140 °F)
The Endress + Hauser Proline Promass I 300 is a straight single-tube Coriolis flowmeter designed for accurate liquid and gas measurement with low pressure loss.
Proline Promass I 500
Coriolis flowmeters
Medium temperature range: –50 to +150 °C (–58 to +302 °F) · Ambient temperature range (Standard): –40 to +60 °C (–40 to +140 °F) · Ambient temperature range (Option): –50 to +60 °C (–58 to +140 °F)
The Endress + Hauser Proline Promass I 500 is a remote transmitter Coriolis flowmeter designed for measuring liquids and gases with low pressure loss and gentle fluid...
Proline Promass K 10
Coriolis flowmeters
Nominal diameter range: DN 8 to 80 (⅜ to 3") · Medium temperature range: –40 to +150 °C (–40 to +302 °F) · Ambient temperature range: Standard: –20 to +60 °C (–4 to +140 °F)
The Endress + Hauser Proline Promass K 10 is a compact Coriolis mass flowmeter designed for cost-efficient measurement of liquids and gases.
Proline Promass O 100
Coriolis flowmeters
Connection: 25Cr duplex (Super Duplex), 1.4410 (F53) · Highest degree of protection: IP69 · Mass flow (liquid): ±0.1 % (standard), 0.05 % (option)
The Proline Promass O 100 is a robust, ultra-compact Coriolis flowmeter designed for premium accuracy in high-pressure liquid and gas applications.
Proline Promass O 300
Coriolis flowmeters
Medium temperature range: –40 to +205 °C (–40 to +401 °F) · Ambient temperature range (Standard): –40 to +60 °C (–40 to +140 °F) · Ambient temperature range (Option): –50 to +60 °C (–58 to +140 °F)
The Endress + Hauser Proline Promass O 300 is a robust Coriolis flowmeter designed for premium accuracy in liquids and gases at the highest process pressures.
Proline Promass O 500
Coriolis flowmeters
Medium temperature range: –40 to +205 °C (–40 to +401 °F) · Ambient temperature range (Standard): –40 to +60 °C (–40 to +140 °F) · Ambient temperature range (Option): –50 to +60 °C (–58 to +140 °F)
The Proline Promass O 500 is a robust, remote-version Coriolis flowmeter designed for premium accuracy in high-pressure liquid and gas applications.
Proline Promass P 100
Coriolis flowmeters
Medium temperature range (Standard): –50 to +150 °C (–58 to +302 °F) · Medium temperature range (Option): –50 to +205 °C (–58 to +401 °F) · Ambient temperature range (Standard): –40 to +60 °C (–40 to +140 °F)
The Endress + Hauser Proline Promass P 100 is a Coriolis flowmeter designed for sterile conditions in the life sciences industry.
Proline Promass P 300
Coriolis flowmeters
Nominal diameter range: DN 8 to 50 (⅜ to 2") · Measuring range: 0 to 70,000 kg/h (0 to 2570 lb/min) · Connection: 1.4435 (316L); 1.4404 (316/316L)
The Endress + Hauser Proline Promass P 300 is a specialist Coriolis mass flow meter designed for sterile applications in the life sciences industry.
Proline Promass P 500
Coriolis flowmeters
Nominal diameter range: DN 8 to 50 (⅜ to 2") · Measuring range: 0 to 70 000 kg/h (0 to 2570 lb/min) · Connection: 1.4435 (316L); 1.4404 (316/316L)
The Proline Promass P 500 is a specialist Coriolis flowmeter designed for sterile processes in the life sciences industry.
Proline Promass Q 300
Coriolis flowmeters
Nominal diameter range: DN 25 to 250 (1 to 10") · Measuring range (Mass Flow): 0 to 2,400,000 kg/h (0 to 88183 lb/min) · Connection: 1.4404 (316/316L)
The Proline Promass Q 300 is a Coriolis flowmeter designed for challenging applications, including custody transfer and liquids with entrained gas.
Proline Promass Q 500
Coriolis flowmeters
Connection: 1.4404 (316/316L) · Sensor connection housing (standard): AlSi10Mg, coated · Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L
The Endress+Hauser Proline Promass Q 500 is a Coriolis flowmeter optimized for challenging custody transfer applications.
Proline Promass S 100
Coriolis flowmeters
Medium temperature range: –50 to +150 °C (–58 to +302 °F) · Ambient temperature range (Standard): –40 to +60 °C (–40 to +140 °F) · Ambient temperature range (Option): –50 to +60 °C (–58 to +140 °F)
The Proline Promass S 100 is a hygienic Coriolis flowmeter designed for food and beverage applications with a self-drainable single-tube system.
Proline Promass S 300
Coriolis flowmeters
Nominal diameter range: DN 8 to 50 (⅜ to 2") · Measuring range: 0 to 70,000 kg/h (0 to 2570 lb/min) · Medium temperature range: –50 to +150 °C (–58 to +302 °F)
The Endress + Hauser Proline Promass S 300 is a hygienic Coriolis flowmeter designed for demanding applications in the food and beverage industry.
Proline Promass S 500
Coriolis flowmeters
Nominal diameter range: DN 8 to 50 (⅜ to 2") · Measuring range: 0 to 70 000 kg/h (0 to 2570 lb/min) · Medium temperature range: –50 to +150 °C (–58 to +302 °F)
The Proline Promass S 500 is a remote Coriolis flowmeter designed for hygienic applications in the food and beverage industry.
Proline Promass X 300
Coriolis flowmeters
Medium temperature range: –50 to +180 °C (–58 to +356 °F) · Measuring range: 0 to 4100 t/h (0 to 4520 tn. sh./h) · Nominal diameter range: DN 300 to 400 (12 to 16")
Product Name:Proline Promass X 300、Product Type:Coriolis flowmeter、Description:Highest capacity four-tube flowmeter with a compact, easily accessible transmitter.
Proline Promass X 500
Coriolis flowmeters
Medium temperature range: –50 to +180 °C (–58 to +356 °F) · Ambient temperature range (Standard): –40 to +60 °C (–40 to +140 °F) · Ambient temperature range (Option): –60 to +60 °C (–76 to +140 °F)
This Proline Promass X 500 is a remote-mount Coriolis flowmeter designed for the highest flow rates and demanding on/offshore oil and gas applications.
Dosimag-5BH
Electromagnetic flowmeters
Ambient temperature range: –40 to +60 °C (–40 to +140 °F) · Measuring range: 0.14 to 1.66 l/s (0.035 to 0.44 gal/s) · Nominal diameter range: DN 4 (⁵⁄₃₂"), 8 (⁵⁄₁₆"), 15 (½"), 25 (1")
The Endress + Hauser Dosimag-5BH is an electromagnetic flowmeter designed for precise dosing and filling of conductive liquids in hygienic applications.
Dosimag-D5AB
Electromagnetic flowmeters
Measuring range: 0.14 to 1.66 l/s (0.035 to 0.44 gal/s) · Medium temperature range (Seal material EPDM): –20 to +130 °C (–4 to +266 °F) · Medium temperature range (Seal material Silicone): –20 to +130 °C (–4 to +266 °F)
The Endress+Hauser Dosimag-D5AB is an electromagnetic flowmeter designed for hygienic dosing and filling of conductive liquids in the Food & Beverage and Life Sciences...
Dosimass-8BE
Electromagnetic flowmeters
Medium temperature range: –40 to +125 °C (–40 to +257 °F); 150 °C allowed for 1 h · Ambient temperature range: –20 to +60 °C (–4 to +140 °F) · Measuring range (Mass flow): 0 to 18 000 kg/h (0 to 660 lb/min)
The Endress+Hauser Dosimass-8BE is a compact Coriolis flow meter designed for filling and bottling applications, measuring mass flow, density, and temperature.
Magphant-DTI200
Electromagnetic flowmeters
Measuring range: 0 to 56'550 m³/h · Medium temperature range: -20 to +120°C (-4 to +248°F) · Ambient temperature range: -20 to 60°C (-4 to 140°F)
The Endress + Hauser Magphant DTI200 is a compact, cost-effective electromagnetic flowmeter and limit switch designed for water applications in utilities.
Picomag-DMA
Electromagnetic flowmeters
Medium temperature range: -10 to 70°C (+14 to +158 °F) · Ambient temperature range: -10 to 60 °C · Measuring range (Volume flow): up to 750 l/min
The Picomag-DMA is an electromagnetic flowmeter designed for conductive liquids in various industries, measuring volume flow, temperature, and conductivity.
Proline-Promag D 10
Electromagnetic flowmeters
Medium temperature range (Liner material polyamide): 0 to +60°C (+32 to +140°F) · Ambient temperature range: -40 to 60°C (-40 to 140°F) · Measuring range: 9 dm³/min to 282 m³/h (2.5 gal/min to 1250 gal/min)
The Proline Promag D 10 is a cost-effective electromagnetic flowmeter designed for basic water applications in installations with limited space and plastic piping.
Proline-Promag E 100
Electromagnetic flowmeters
Measuring range: 4 dm³/min to 9600 m³/h (1 to 44 000 gal/min) · Nominal diameter range: DN 15 to 600 (½ to 24") · Medium temperature range: –10 to +110 °C (+14 to +230 °F)
The Endress + Hauser Proline Promag E 100 is an economical magnetic flowmeter designed for basic applications in the chemical and process industry.
Proline-Promag H 10
Electromagnetic flowmeters
Nominal diameter range: DN 2 to 150 (¹⁄₁₂ to 6") · Measuring range (Volume flow): 0.06 dm³/min to 600 m³/h (0.015 to 2650 gal/min) · Medium temperature range: –20 to +150 °C (–4 to +302 °F)
The Proline Promag H 10 is an electromagnetic flowmeter designed for basic hygienic applications in the food and beverage and life sciences industries.
Proline-Promag H 100
Electromagnetic flowmeters
Nominal diameter range: DN 2 to 150 (¹⁄₁₂ to 6") · Measuring range: 0.06 dm³/min to 600 m³/h (0.015 to 2650 gal/min) · Medium temperature range: –20 to +150 °C (–4 to +302 °F)
This is an electromagnetic flowmeter designed for hygienic applications in the food, beverage, and life sciences industries.
Proline-Promag H 200
Electromagnetic flowmeters
Measuring range: 0.06 dm³/min to 300 m³/h (0.015 to 80 gal/min) · Medium temperature range: –20 to +150 °C (–4 to +302 °F) · Ambient temperature range: –40 to +60 °C (–40 to +140 °F)
This is an electromagnetic flowmeter designed for the measurement of smallest flow rates with genuine loop-powered technology. It features a PFA liner.
Proline-Promag H 500
Electromagnetic flowmeters
Medium temperature range: –20 to +150 °C (–4 to +302 °F) · Ambient temperature range: –40 to +60 °C (–40 to +140 °F) · Measuring range: 0.06 dm³/min to 600 m³/h (0.015 gal/min to 2 650 gal/min)
The Proline Promag H 500 is an electromagnetic flowmeter designed for demanding hygienic applications in the food and beverage and life sciences industries.
Proline-Promag P 10
Electromagnetic flowmeters
Measuring range: 4 dm³/min to 9600 m³/h (1 gal/min to 44 000 gal/min) · Medium temperature range (Liner PFA): –20 to +150 °C (–4 to +302 °F) · Medium temperature range (Liner PTFE): –40 to +130 °C (–40 to +266 °F)
The Endress+Hauser Proline Promag P 10 is an electromagnetic flowmeter designed for basic process applications with corrosive liquids and high medium temperatures.
Proline-Promag P 100
Electromagnetic flowmeters
Measuring range: 4 dm³/min to 9600 m³/h (1 to 44,000 gal/min) · Nominal diameter range: DN 15 to 600 (½ to 24") · Power supply: DC 20 to 30 V
The Endress + Hauser Proline Promag P 100 is an electromagnetic flowmeter designed for corrosive liquids and high medium temperatures.
Proline-Promag P 200
Electromagnetic flowmeters
Measuring range: 4 dm³/min to 1100 m³/h (1 to 4850 gal/min) · Nominal diameter range: DN 15 to 200 (½ to 8") · Power supply: DC 18 to 35 V (for 4–20 mA HART with/without pulse/frequency/switch output)
The Proline Promag P 200 is an electromagnetic flowmeter designed for corrosive liquids and high temperatures, suitable for hazardous areas.
Proline-Promag P 300
Electromagnetic flowmeters
Measuring range: 4 dm³/min to 9600 m³/h (1 gal/min to 44 000 gal/min) · Nominal diameter range: DN 15 to 600 (½ to 24") · Power supply: DC 24 V, AC 100 to 230 V, AC 100 to 230 V / DC 24 V (non-hazardous area)
The Proline Promag P 300 is a high-temperature electromagnetic flowmeter designed for corrosive liquids in demanding chemical and process applications.
Proline-Promag P 500
Electromagnetic flowmeters
Nominal diameter range: DN 15 to 600 (½ to 24") · Sensor connection housing (standard): AlSi10Mg, coated · Sensor connection housing (option): 1.4409 (CF3M) similar to 316L
The Proline Promag P 500 is a remote-version electromagnetic flowmeter designed for high-temperature and corrosive chemical process applications.
Proline-Promag W 10
Electromagnetic flowmeters
Measuring range: 0.5 m³/h to 263,000 m³/h (2.5 gal/min to 1665 Mgal/d) · Ambient temperature range: -40 to +60 °C (-40 to +140 °F) · Nominal diameter range: DN 25 to 3000 (1 to 120")
This is an electromagnetic flowmeter designed for basic water and wastewater applications, featuring international drinking water approvals.
Proline-Promag W 300
Electromagnetic flowmeters
Sensor connection housing (standard): AlSi10Mg, coated · Sensor connection housing (option): Polycarbonate; 1.4409 (CF3M) similar to 316L · Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
The Proline Promag W 300 is an electromagnetic flowmeter designed for demanding water and wastewater applications.
Proline-Promag W 400
Electromagnetic flowmeters
Nominal diameter range: DN 25 to 3000 (1 to 120") · Measuring range: 0.5 m³/h to 263000 m³/h (2.5 gal/min to 1665 Mgal/d) · Medium temperature range (Liner material hard rubber): 0 to +80 °C (+32 to +176 °F)
This versatile standard flowmeter is designed for the water and wastewater industry, offering reliable measurement with no pressure loss and flexible engineering for...
Proline-Promag W 500
Electromagnetic flowmeters
Ambient temperature range (Flange material carbon steel): –10 to +60 °C · Ambient temperature range (Flange material stainless steel): –40 to +60 °C · Nominal diameter range: DN 25 to 3000 (1 to 120")
The Proline Promag W 500 is an electromagnetic flowmeter specialized for demanding water and wastewater applications, available in a remote version with up to four I/Os.
Proline-Promag W 800
Electromagnetic flowmeters
Medium temperature range (Liner material hard rubber): 0 to +70 °C (+32 to +158 °F) · Medium temperature range (Liner material polyurethane): –20 to +50 °C (–4 to +122 °F) · Medium temperature range (Liner material PTFE): -20 to 70°C (–4 to +158 °F)
This is a battery-powered electromagnetic flowmeter designed for water industry applications.
Promag 55S
Electromagnetic flowmeters
Measuring range: 0.06 dm³/min to 600 m³/h (0.015 gal/min to 2650 gal/min) · Ambient temperature range: –40 to +60 °C (–40 to +140 °F) · Nominal diameter range: DN 15...600 (1/2"...24")
The Endress+Hauser Promag 55S is an electromagnetic flowmeter designed for abrasive, corrosive, and inhomogeneous fluids with integrated solids content diagnostics.
Proline Prosonic Flow E 100
Ultrasonic flowmeters
Measuring range (Flow velocity): 0.025 to 5 m/s (0.02 to 16.4 ft/s) · Measuring range (Volume flow): 0 to 6360 dm³/min (0 to 1680 gal/min) · Medium temperature range: 0 to 150 °C (17.8 to 302 °F)
The Proline Prosonic Flow E 100 is an economical ultrasonic flowmeter with integrated temperature measurement for demineralized water applications.
Proline Prosonic Flow I 400
Ultrasonic flowmeters
Medium temperature range: –40 to +80 °C (–40 to +176 °F) · Ambient temperature range: -20 to 60°C (-4 to 140°F) · Nominal diameter range: DN200 to 4000 (8 to 160")
The Endress + Hauser Proline Prosonic Flow I 400 is an insertion ultrasonic flowmeter designed for water and wastewater applications in large pipelines.
Proline Prosonic Flow W 400
Ultrasonic flowmeters
Medium Temperature Range: –40 to +130 °C (–40 to +266 °F) · Ambient Temperature Range (Sensor): -40 to 130 °C for all sensor sizes (DN 15 to 4000) · Measuring Range: 0 to 15 m/s (0 to 50 ft/s)
The Endress + Hauser Proline Prosonic Flow W 400 is an ultrasonic clamp-on flowmeter designed for reliable and maintenance-free measurement of conductive and...
Promass U 500
Ultrasonic flowmeters
Medium Temperature Range: 3 to 60°C (37.4 to 140°F) · Ambient Temperature Range: 5 to 40°C (41 to 104°F) · Measuring Range: 0 to 75 kg/h (0 to 165.3 lb/min)
The Endress + Hauser Promass U 500 is a Coriolis flowmeter designed for single-use biopharmaceutical applications, particularly in monoclonal antibody processes.
Prosonic Flow Clamp On 9P5B
Ultrasonic flowmeters
Nominal diameter range: Dual channel, 1 or 2 paths : DN 15 to 4000 (1/2 to 160") · Measuring range: 0 to 15 m/s (0 to 50 ft/s) · Transmitter housing material: AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L
This Prosonic Flow Clamp On 9P5B is an ultrasonic clamp-on flowmeter for various fluids in process industries.
Prosonic Flow Clamp On 91W
Ultrasonic flowmeters
Ambient temperature range: -20 to +60 °C (-4 to +140 °F) · Nominal diameter range: Single channel, 1 or 2 paths: DN15 to 2000 (1/2 to 80") · Measuring range: 0.3 to 10 m/s (1 to 33 ft/s)
The Endress + Hauser Prosonic Flow 91W is a clamp-on ultrasonic flow meter for process water, salt water, and wastewater. It features a single-channel.
Prosonic Flow Clamp On 93TA1
Ultrasonic flowmeters
Measuring range: 0....452'389 m³/h · Degree of protection: IP 40 · Max. process pressure: No limit
The Prosonic Flow Clamp On 93TA1 is a portable ultrasonic flowmeter designed for temporary monitoring and test measurements of liquid applications from outside the pipe.
Prosonic Flow E Heat 9EHB
Ultrasonic flowmeters
Medium temperature range: 0 to 150 °C (17.8 to 302 °F) · Ambient temperature range: -20 to 60 °C (-4 to 140 °F) · Measuring range (velocity): 0.025 to 5 m/s (0.02 to 16.4 ft/s)
The Endress + Hauser Prosonic Flow E Heat 9EHB is an industrial ultrasonic heat flow sensor designed for enhanced energy management and custody transfer.
Prosonic Flow Inline 92F
Ultrasonic flowmeters
Medium temperature range: -40 to +150 °C (-40 to +302 °F) · Medium temperature range (optional): -40 to +200 °C (-40 to +392 °F) · Ambient temperature range (compact): -40 to +60 °C (-40 to +140 °F)
The Prosonic Flow Inline 92F is an ultrasonic flowmeter designed for homogeneous conductive and non-conductive liquids in the chemical and petrochemical industries.
Teqwave F
Ultrasonic flowmeters
Medium temperature range: 0 to 100 °C (32 to 212 °F) · Ambient temperature range: 0 to 50°C (32 to 122°F) · Nominal diameter range: DN 8 (1/4“) to DN 25 (1“)
The Teqwave F is an inline ultrasonic concentration meter designed for real-time liquid analysis in pipes.
Teqwave H
Ultrasonic flowmeters
Process Temperature Range: 0 to 120°C (32 to 248 °F) · Ambient Temperature Range: 0 to 60 °C (32 to 140 °F) · Power Supply: DC 24V ±20%
PDF datasheet mirror for Teqwave H (Endress + Hauser Flow measurement).
Teqwave I
Ultrasonic flowmeters
Process temperature range: 0 to 100 °C (32 to 212 °F) · Medium temperature range: 0 to 100 °C (32 to 212 °F) · Ambient temperature range: 0 to 50 °C (32 to 122 °F)
The Endress + Hauser Teqwave I is an insertion-type ultrasonic concentration meter designed for real-time liquid analysis in vessels and larger pipes.
Teqwave T
Ultrasonic flowmeters
Medium temperature range: 0 to +100 °C (32 to +212 °F) · Ambient temperature range: 0 to 40 °C (32 to 122 °F) · Power supply: Lithium-ion battery, 2300 mAh capacity
The Endress+ Hauser Teqwave T is a portable ultrasonic concentration meter designed for in situ liquid analysis. It features a stainless steel sensor housing.
Flowphant-T-DTT31
Thermal mass flowmeters
Medium temperature range: -20...+85°C (-4...+185°F) · Nominal diameter range: DN 25...1000 (1"...40") · Max. process pressure: 100 bar (1.740 psi)
The Endress + Hauser Flowphant T DTT31 is an intelligent insertion-style thermal flow switch for liquid applications, featuring practically no pressure loss.
Proline Prowirl D 200
Vortex flowmeters
Nominal diameter range: DN 15 to 150 (½ to 6") · Face-to-face length: 65 mm (2.56 in) · Volume flow (liquid): ±0.75 %
The Endress + Hauser Proline Prowirl D 200 is a cost-effective vortex flowmeter available in compact or remote versions.
Proline Prowirl F 200
Vortex flowmeters
Nominal diameter range: DN 15 to 300 (½ to 12") · Measuring range (Liquid): 0.2 to 2100 m³/h (0.15 to 1520 ft³/min) · Measuring range (Steam, gas): 1.5 to 28000 m³/h (0.9 to 16600 ft³/min)
The Proline Prowirl F 200 is a multivariable vortex flowmeter designed for reliable steam, gas, and liquid measurement.
Proline Prowirl O 200
Vortex flowmeters
Nominal diameter range: DN 15 to 300 (½ to 12") · Process connection: 1.4404/F316/F316L · Max. process pressure: PN 250, Class 1500, 40K
The Endress + Hauser Proline Prowirl O 200 is a vortex flowmeter designed for demanding gas and steam applications with high process pressure.
Proline Prowirl R 200
Vortex flowmeters
Nominal diameter range: DN 25 to 250 (1 to 10") · Accuracy: Same accuracy down to Re 10,000 · Process connection: 1.4404/F316/F316L
The Endress + Hauser Proline Prowirl R 200 is a vortex flowmeter designed for low flows and energy management, featuring integrated pipe reduction.
IFLRUN
Differential flow measurement
Medium temperature range: –40 °C to +180 °C · Pressure rating: 150 / 300 / 600 / 900 / 1,500 / 2,500 · Materials in contact with the medium: Low temperature carbon steel, stainless steel
The FLOWRUN is a modular gas metering system designed for industry-standard applications with low measurement uncertainty. It can include upstream and downstream piping.
Brand Products & Technical Documents
Each card keeps the curated model introduction and combines the readable datasheet page, OEM PDF, and official source. Product understanding and document access now share one card set.
35 product profiles
Product profile
The Proline Cubemass C 300 is a compact Coriolis flowmeter designed for measuring small flow rates in skids, test rigs, and robotics.
Product profile
The Proline Cubemass C 500 is a compact Coriolis flowmeter designed for measuring the smallest flow rates in skids, test rigs, and industrial robotics.
Product profile
The Endress + Hauser Proline Promass A 100 is a compact Coriolis flowmeter designed for precise measurement of small liquid and gas quantities.
Product profile
The Proline Promass A 200 is a loop-powered Coriolis flowmeter designed for accurate measurement of lowest flow rates in demanding applications.
Product profile
The Endress+Hauser Proline Promass A 300 is a compact Coriolis flowmeter designed for continuous process control of liquids and gases.
Product profile
The Endress + Hauser Proline Promass A 500 is a compact Coriolis flowmeter designed for demanding applications.
Product profile
The Proline Promass E 100 is a mid-range Coriolis flowmeter designed for accurate liquid and gas measurement in standard applications with an ultra-compact transmitter.
Product profile
The Endress + Hauser Proline Promass E 200 is a Coriolis flowmeter designed for accurate liquid and gas measurement in standard chemical industry applications.
Product profile
The Endress + Hauser Proline Promass E 300 is a mid-range Coriolis flowmeter designed for accurate measurement of liquids and gases in standard applications.
Product profile
PDF datasheet mirror for Proline Promass E 500 (Endress + Hauser Flow measurement).
Product profile
The Proline Promass F 100 is an ultra-compact Coriolis flowmeter designed for precise measurement of mass flow, density, and temperature.
Product profile
The Proline Promass F 200 is a robust Coriolis flowmeter offering high measurement performance for liquids and gases across various applications.
Product profile
The Proline Promass F 300 is a Coriolis flowmeter offering premium accuracy and robustness for mass and volume flow measurement.
Product profile
The Proline Promass F 500 is a high-accuracy Coriolis flowmeter for demanding liquid and gas applications, featuring integrated Heartbeat Technology for reliability.
Product profile
The Endress + Hauser Proline Promass G 100 is a compact Coriolis flowmeter designed for accurate measurement of liquids and gases in high-pressure applications.
Product profile
The Proline Promass H 100 is a chemically resistant Coriolis flowmeter with an ultra-compact transmitter, designed for aggressive fluids in space-constrained applications.
Product profile
The Proline Promass H 300 is a highly accurate, chemically resistant Coriolis flowmeter designed for aggressive fluids.
Product profile
The Proline Promass H 500 is a remote version Coriolis flowmeter designed for aggressive fluids requiring highest corrosion resistance and accuracy.
Product profile
The Endress + Hauser Proline Promass I 100 is an ultra-compact Coriolis flowmeter designed for measuring liquids and gases with minimal pressure loss.
Product profile
The Endress + Hauser Proline Promass I 300 is a straight single-tube Coriolis flowmeter designed for accurate liquid and gas measurement with low pressure loss.
Product profile
The Endress + Hauser Proline Promass I 500 is a remote transmitter Coriolis flowmeter designed for measuring liquids and gases with low pressure loss and gentle fluid...
Product profile
The Endress + Hauser Proline Promass K 10 is a compact Coriolis mass flowmeter designed for cost-efficient measurement of liquids and gases.
Product profile
The Proline Promass O 100 is a robust, ultra-compact Coriolis flowmeter designed for premium accuracy in high-pressure liquid and gas applications.
Product profile
The Endress + Hauser Proline Promass O 300 is a robust Coriolis flowmeter designed for premium accuracy in liquids and gases at the highest process pressures.
Product profile
The Proline Promass O 500 is a robust, remote-version Coriolis flowmeter designed for premium accuracy in high-pressure liquid and gas applications.
Product profile
The Endress + Hauser Proline Promass P 100 is a Coriolis flowmeter designed for sterile conditions in the life sciences industry.
Product profile
The Endress + Hauser Proline Promass P 300 is a specialist Coriolis mass flow meter designed for sterile applications in the life sciences industry.
Product profile
The Proline Promass P 500 is a specialist Coriolis flowmeter designed for sterile processes in the life sciences industry.
Product profile
The Proline Promass Q 300 is a Coriolis flowmeter designed for challenging applications, including custody transfer and liquids with entrained gas.
Product profile
The Endress+Hauser Proline Promass Q 500 is a Coriolis flowmeter optimized for challenging custody transfer applications.
Product profile
The Proline Promass S 100 is a hygienic Coriolis flowmeter designed for food and beverage applications with a self-drainable single-tube system.
Product profile
The Endress + Hauser Proline Promass S 300 is a hygienic Coriolis flowmeter designed for demanding applications in the food and beverage industry.
Product profile
The Proline Promass S 500 is a remote Coriolis flowmeter designed for hygienic applications in the food and beverage industry.
Product profile
Product Name:Proline Promass X 300、Product Type:Coriolis flowmeter、Description:Highest capacity four-tube flowmeter with a compact, easily accessible transmitter.
Product profile
This Proline Promass X 500 is a remote-mount Coriolis flowmeter designed for the highest flow rates and demanding on/offshore oil and gas applications.
22 product profiles
Product profile
The Endress + Hauser Dosimag-5BH is an electromagnetic flowmeter designed for precise dosing and filling of conductive liquids in hygienic applications.
Product profile
The Endress+Hauser Dosimag-D5AB is an electromagnetic flowmeter designed for hygienic dosing and filling of conductive liquids in the Food & Beverage and Life Sciences...
Product profile
The Endress+Hauser Dosimass-8BE is a compact Coriolis flow meter designed for filling and bottling applications, measuring mass flow, density, and temperature.
Product profile
The Endress + Hauser Magphant DTI200 is a compact, cost-effective electromagnetic flowmeter and limit switch designed for water applications in utilities.
Product profile
The Picomag-DMA is an electromagnetic flowmeter designed for conductive liquids in various industries, measuring volume flow, temperature, and conductivity.
Product profile
The Proline Promag D 10 is a cost-effective electromagnetic flowmeter designed for basic water applications in installations with limited space and plastic piping.
Product profile
The Endress + Hauser Proline Promag E 100 is an economical magnetic flowmeter designed for basic applications in the chemical and process industry.
Product profile
The Proline Promag H 10 is an electromagnetic flowmeter designed for basic hygienic applications in the food and beverage and life sciences industries.
Product profile
This is an electromagnetic flowmeter designed for hygienic applications in the food, beverage, and life sciences industries.
Product profile
This is an electromagnetic flowmeter designed for the measurement of smallest flow rates with genuine loop-powered technology. It features a PFA liner.
Product profile
The Proline Promag H 500 is an electromagnetic flowmeter designed for demanding hygienic applications in the food and beverage and life sciences industries.
Product profile
The Endress+Hauser Proline Promag P 10 is an electromagnetic flowmeter designed for basic process applications with corrosive liquids and high medium temperatures.
Product profile
The Endress + Hauser Proline Promag P 100 is an electromagnetic flowmeter designed for corrosive liquids and high medium temperatures.
Product profile
The Proline Promag P 200 is an electromagnetic flowmeter designed for corrosive liquids and high temperatures, suitable for hazardous areas.
Product profile
The Proline Promag P 300 is a high-temperature electromagnetic flowmeter designed for corrosive liquids in demanding chemical and process applications.
Product profile
The Proline Promag P 500 is a remote-version electromagnetic flowmeter designed for high-temperature and corrosive chemical process applications.
Product profile
This is an electromagnetic flowmeter designed for basic water and wastewater applications, featuring international drinking water approvals.
Product profile
The Proline Promag W 300 is an electromagnetic flowmeter designed for demanding water and wastewater applications.
Product profile
This versatile standard flowmeter is designed for the water and wastewater industry, offering reliable measurement with no pressure loss and flexible engineering for...
Product profile
The Proline Promag W 500 is an electromagnetic flowmeter specialized for demanding water and wastewater applications, available in a remote version with up to four I/Os.
Product profile
This is a battery-powered electromagnetic flowmeter designed for water industry applications.
Product profile
The Endress+Hauser Promag 55S is an electromagnetic flowmeter designed for abrasive, corrosive, and inhomogeneous fluids with integrated solids content diagnostics.
13 product profiles
Product profile
The Proline Prosonic Flow E 100 is an economical ultrasonic flowmeter with integrated temperature measurement for demineralized water applications.
Product profile
The Endress + Hauser Proline Prosonic Flow I 400 is an insertion ultrasonic flowmeter designed for water and wastewater applications in large pipelines.
Product profile
The Endress + Hauser Proline Prosonic Flow W 400 is an ultrasonic clamp-on flowmeter designed for reliable and maintenance-free measurement of conductive and...
Product profile
The Endress + Hauser Promass U 500 is a Coriolis flowmeter designed for single-use biopharmaceutical applications, particularly in monoclonal antibody processes.
Product profile
This Prosonic Flow Clamp On 9P5B is an ultrasonic clamp-on flowmeter for various fluids in process industries.
Product profile
The Endress + Hauser Prosonic Flow 91W is a clamp-on ultrasonic flow meter for process water, salt water, and wastewater. It features a single-channel.
Product profile
The Prosonic Flow Clamp On 93TA1 is a portable ultrasonic flowmeter designed for temporary monitoring and test measurements of liquid applications from outside the pipe.
Product profile
The Endress + Hauser Prosonic Flow E Heat 9EHB is an industrial ultrasonic heat flow sensor designed for enhanced energy management and custody transfer.
Product profile
The Prosonic Flow Inline 92F is an ultrasonic flowmeter designed for homogeneous conductive and non-conductive liquids in the chemical and petrochemical industries.
Product profile
The Teqwave F is an inline ultrasonic concentration meter designed for real-time liquid analysis in pipes.
Product profile
PDF datasheet mirror for Teqwave H (Endress + Hauser Flow measurement).
Product profile
The Endress + Hauser Teqwave I is an insertion-type ultrasonic concentration meter designed for real-time liquid analysis in vessels and larger pipes.
Product profile
The Endress+ Hauser Teqwave T is a portable ultrasonic concentration meter designed for in situ liquid analysis. It features a stainless steel sensor housing.
1 product profile
Product profile
The Endress + Hauser Flowphant T DTT31 is an intelligent insertion-style thermal flow switch for liquid applications, featuring practically no pressure loss.
4 product profiles
Product profile
The Endress + Hauser Proline Prowirl D 200 is a cost-effective vortex flowmeter available in compact or remote versions.
Product profile
The Proline Prowirl F 200 is a multivariable vortex flowmeter designed for reliable steam, gas, and liquid measurement.
Product profile
The Endress + Hauser Proline Prowirl O 200 is a vortex flowmeter designed for demanding gas and steam applications with high process pressure.
Product profile
The Endress + Hauser Proline Prowirl R 200 is a vortex flowmeter designed for low flows and energy management, featuring integrated pipe reduction.
2 product profiles
Product profile
The FLOWRUN is a modular gas metering system designed for industry-standard applications with low measurement uncertainty. It can include upstream and downstream piping.
Product profile
The Endress + Hauser FLOWSKID is a complete gas flow metering system designed for custody transfer applications.