العودة إلى Testomat
Testomat logo

ملخص ورقة البيانات

Testomat 2000 CLF

Engineering summary from PDF text extraction for Testomat 2000 CLF. Verify every value with the OEM datasheet.

Summary

Product identification

The Testomat 2000® CLF is a wet-chemical online process photometer for monitoring free chlorine.

Application

  • Monitoring of chlorination systems for drinking water/swimming pool water
  • Protection for reverse osmosis membranes
  • Monitoring of biocides and conditioning agents containing chlorine

Operating limits

  • Ambient temperature: 10–45 °C (50 - 104°F)
  • Water temperature: 10 to 40 °C (50 to 104°F)

Feed water

  • Operating pressure: 1 to 8 bar (15 to 116 psi) OR 0.3 to 1 bar (5 to 15 psi) (after removing valve body from regulator/filter housing)
  • Water inlet: Opaque hose with 6 mm external diameter / 4 mm internal diameter
  • Mains water supply

Product water

  • Measuring range (Free chlorine): 0.00 - 0.99 mg/l and 1.0 - 2.5 mg/l
  • Water outlet: Hose with 6 mm external diameter / 4 mm internal diameter

Electrical

  • Power supply: 230–240 VAC, 115 VAC, 24 VAC (all 50–60Hz)
  • Power consumption: max. 30 VA
  • Protection class: I
  • Degree of protection: IP 65

Mechanical / hydraulic

  • Dimensions (Width x Height x Depth): 380 x 480 x 280 mm
  • Weight: approx. 9.5 kg
  • Menu languages: German, English, French, Italian (others upon request)
  • Option: booster pump (see accessories)

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

أُعد المحتوى من مراجع تقنية عامة للبحث والمقارنة الأولية. لا يغني الملخص عن ورقة بيانات حالية معتمدة من الشركة المصنعة. تحقق من الإصدارات وحدود التصميم قبل الاستخدام.