Tóm tắt tài liệu kỹ thuật
FS10-FC-FUS5082
PDF datasheet mirror for FS10-FC-FUS5082 (Microdyn-Nadir UF). Verify with OEM before design.
Summary
Product identification
- Module Name: FS10-FC-FUS5082
- Product Type: ULTRADYN Hollow Fiber UF Membrane Module
- Manufacturer: DAICEN Membrane Systems Ltd. (markets and distributes under the registered trademark MOLSEP®)
Standard Configurations
- Filtration Type: Ultrafiltration
- Membrane Material: Polyethersulfone
- Molecular Cutoff: 500,000 Dalton
- Hollow Fiber Inner Diameter: 0.8 mm
- Membrane Area: 5.0 m²
- Standard Preservative: 1000 ppm Benzoic acid
Operating Limits
- Max. Feed Inlet Pressure: 0.6 MPa (at room temperature)
- Max. Transmembrane Pressure: 0.3 MPa
- Max. Temperature: 98 °C
- Applicable pH Range: 1 ~ 13
- Note: Applicable max. pressure depends on operating temperature. Ensure instruction manual.
Performance Data
- Standard Water Flux: 5.3 m³/h (Initial water flux by dead end filtration with pure water under T.M.P. 0.1 MPa at 25°C)
- Shipping Water Flux Range: 4.4 m³/h (Initial water flux by dead end filtration with pure water under T.M.P. 0.1 MPa at 25°C)
- Standard Inlet Feed Flow: 3.8 m³/h (Adjusted to 1 m/sec feed velocity; optimum velocity may differ per application)
Mechanical / Hydraulic
- Weight at Operation: 8.5 kg
- Weight at Shipping: 2.5 kg
- Connectors:
- Feed/Concentrate: 2S Ferrule
- Permeate: 1S Ferrule
- Module Components:
- Nozzle cap: Polysulfone (2 units)
- Cap: Polysulfone (2 units)
- Case: Polysulfone (1 unit)
- O-Ring type WG-21: FPM (Fluoro rubber) (2 units)
- Potting resin: Epoxy resin
- Note: Specific dimensions for module components are available in the official PDF.
Disclaimer
MICRODYN-NADIR reserves the right to change specifications without prior notification. This extraction may miss figures, footnotes, or revisions present in the original document. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Nội dung tổng hợp từ tài liệu kỹ thuật công khai nhằm tra cứu và so sánh sơ bộ. Bản tóm tắt không thay thế bảng dữ liệu hiện hành được nhà sản xuất chứng nhận. Kiểm tra phiên bản và giới hạn thiết kế trước khi sử dụng.