Back to SUEZ Filtration
SUELogo pending

Datasheet summary

Memtrex MP CMMP capsules

Engineering summary from PDF text extraction for Memtrex MP CMMP capsules. Verify every value with the OEM datasheet.

Summary

Product identification

Memtrex MP capsule filters (CMMP) feature unique polyethersulfone membranes. These capsules are rinsed with DI water during manufacturing.

Product characteristics

  • High throughput and precise retention characteristics
  • Broad chemical compatibility — ideal for filtration of acids, bases, and solvents
  • Individually integrity tested during manufacturing
  • Rinsed with DI water during manufacturing for improved cleanliness and rinse-up times
  • Low protein binding membrane suitable for biopharmaceutical processes

Applications

Memtrex MP capsule filters are designed for process fluid filtration in the beverage, pharmaceutical, and electronics industries, including applications such as filtration of:

  • Acids, bases, and oxidants
  • Serums and tissue culture media
  • Pharmaceutical intermediates
  • Fine inks and dyes
  • Point-of-use for process water

Available configurations

Memtrex MP Capsule Filters are available in absolute micron ratings of:

  • 0.1 µm
  • 0.2 µm
  • 0.45 µm
  • 0.65 µm

Materials of Construction

  • Filtration Media: Hydrophilic Polyethersulfone Membrane
  • Membrane Support Layers: Polypropylene Microfiber
  • Structural Components: Polypropylene

Dimensions

  • Diameter: 3.5” (9 cm)
  • Capsule Size / Effective Filtration Area / Length (varies with connection style):
    • Small: 0.8 ft² (748 cm²), 3.5 – 5.0” (9 – 13 cm)
    • Medium: 3.0 ft² (2806 cm²), 7.6 – 9.1” (19 – 23 cm)
    • Large: 5.9 ft² (5500 cm²), 11.5 – 13.0” (29 – 33 cm)

Operating limits

  • Max. Operational Pressure:
    • 80 psi (5.5 bar) at 70ºF (21ºC) in liquid
    • 55 psi (3.8 bar) at 70ºF (21ºC) in gas
  • Max. Differential Pressure: 60 psi (4.1 bar) at 70ºF (21ºC)
  • Max. Operating Temperature: 110ºF (43ºC) at ≤30 psid (2.1 bar)

Product water

Integrity Testing

Integrity testing is performed by air diffusion through water saturated membrane.

  • Micron Rating / Test Pressure / Specification:
    • 0.1 µm / 50 psi (3.4 bar) / ≤5.6 cc/min per ft² of EFA
    • 0.2 µm / 30 psi (2.1 bar) / ≤2.4 cc/min per ft² of EFA
    • 0.45 µm / 20 psi (1.4 bar) / ≤2.0 cc/min per ft² of EFA
    • 0.65 µm / 13 psi (0.9 bar) / ≤1.5 cc/min per ft² of EFA

Sanitization

Memtrex MP capsule filters can be sanitized with a variety of commonly used chemical agents. They can be repeatedly autoclaved at 257°F (125°C) for 30 minutes, up to 5 cycles.

Certifications and compliance

The materials contained in these capsule filters meet U.S. FDA requirements for food contact under applicable regulations in 21 CFR. They also meet the test criteria for USP class VI-121°C Plastics.

Ordering information

Capsules can be ordered by specifying the model type (CMMP), absolute micron rating (0.1, 0.2, 0.45, 1.0 µm), capsule size (small, medium, large), and connections. Available connection types include:

  • ¼” – ½” (6.3 – 12.7 mm) hose barb
  • 3/8” (9.5 mm) hose barb
  • ¼” (6.3 mm) NPT male
  • ½” (12.7 mm) NPT male
  • 1.5” (38.1 mm) sanitary flange

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must always match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.