Datasheet summary
Flotrex HR
Engineering summary from PDF text extraction for Flotrex HR. Verify every value with the OEM datasheet.
Summary
Product Identification
The Flotrex HR (FHR) filters are pleated filters constructed entirely from Halar (ECTFE), an industrial-grade fluoropolymer. They are designed for robust performance in harsh chemical environments, offering broad chemical compatibility and consistent, uniform process streams.
- Materials of Construction:
- Media: Halar Microfiber
- Support Layers: Halar
- Core and Cage: Halar
- Endcaps and Adapters: Halar
- Absolute Micron Ratings: 3, 10, and 25 µm
- Filtration Efficiency: 99.9% at rated pore size (based on ASTM F795 and F661 test methods)
- Manufacturing: Produced and packaged in a cleanroom environment for assured cleanliness.
- Applications: Designed for both pre- and final filtration in demanding applications, including:
- Filtration of aggressive chemicals (e.g., Toluene and Xylene)
- Filtration of Ozonated Water
- Beverage
Operating Limits
- Maximum Forward Differential Pressure: 60 psi (4.1 bar) at 70ºF (21ºC)
- Maximum Reverse Differential Pressure: 30 psi (2.1 bar) at 70ºF (21ºC)
- Maximum Operating Temperature: 180ºF (82ºC) at 10 psid (0.69 bar) in water
Mechanical / Hydraulic
- Nominal Outer Diameter: 2.75” (70 mm)
- Nominal Inner Diameter: 1.25” (31 mm)
- Effective Filtration Area: 8.0 ft² (0.74 m²)
- Nominal Cartridge Lengths: 10 in (25 cm), 20 in (51 cm), 30 in (76 cm), 40 in (102 cm)
- End #1 Adapter Options: Open End Gasket, 222 O-Ring, 226 O-Ring
- End #2 Adapter Options: Open End Gasket, Closed End Cap, Fin Adapter
- Elastomer Materials: Viton, Teflon, Encapsulated Viton
- Flow Performance in Clean Water: See the official PDF for exact tabulated values.
Additional Features
- Sanitization: Filters may be sanitized with compatible chemical agents, such as ozonated water. They must not be autoclaved or steam sterilized.
- Biocompatibility: Meets the test criteria for USP24 Class VI-121°C Plastics and passes the MEM Elution Cytotoxicity Test.
- Extractables: Aqueous extracts contain less than 0.25 EU/ml. Filters typically exhibit low levels of non-volatile residues.
- Ozone Tolerance: FHR filters are ozone tolerant for 9,000 ppm/hr with no extractables.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the OEM PDF datasheet. For contractual data, please refer to the specific OEM PDF revision used on your project.