Quay lại Pentek filters
Pentair logo

Tóm tắt tài liệu kỹ thuật

Polyval Cartridges

Engineering summary from PDF text extraction for Polyval Cartridges. Verify every value with the OEM datasheet.

Summary

Product Identification

Polyval® and Polyval® HE pleated polypropylene cartridges offer an economic alternative for initial fine filtration stages. They are designed to filter water or fluids from the point of entry to the point of use, including secondary circuit systems in industrial processes.

  • Polyval®: Continuous length construction with 90% filtration efficiency.
  • Polyval® HE: 10'' module construction with 98% filtration efficiency.
  • Filtration Thresholds: From 0.2 µm to 40 µm.
  • High surface retention capacity.
  • Excellent chemical compatibility.
  • Resistance to bacterial aggression.
  • No fiber release.
  • Available end cap types: DOE, 3S, 3F, 7S, 7F.

Operating Limits

  • Media: Polypropylene
  • Operating Temperature: 5°C – 65°C
  • Frame/Structure: Polypropylene
  • End Caps: Polypropylene
  • Seal: Neoprene
  • Maximum Differential Pressure (Delta P):
    • Polyval: 2.4 bar
    • Polyval HE: 2.5 bar

Performance and Dimensions

  • Filtration Thresholds (nominal): 0.2 µm, 0.45 µm, 1 µm, 5 µm, 20 µm, 40 µm.
  • Filtration Efficiency:
    • Polyval: 90%
    • Polyval HE: 98%
  • Available Lengths: 9-3/4'', 10'', 20'', 30'', 40''.
  • Filtration Surface Area (for a 10'' length):
    • Polyval: 0.30 m²
    • Polyval HE: 0.57 m²

For specific Efiltec reference numbers, lengths, filtration thresholds, and end cap combinations, please refer to the official PDF.

Applications

  • Filtration of well water or tap water.
  • Filtration of process water to protect sensitive systems and equipment.
  • Boiler feed water filtration.
  • Recycled water filtration.
  • Chemical filtration.

Precautions for Use

  • Performance is dependent on proper system sizing.
  • Certain applications may require water treatment systems to comply with specific standards or certifications.
  • These cartridges should not be used with microbiologically unsafe water or fluid.
  • Polyval cartridges are not classified as medical devices.

Disclaimer: This summary is based on the provided text extract. It may not include all figures, footnotes, or revisions present in the complete OEM PDF datasheet. Contractual data must match the specific OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Nội dung tổng hợp từ tài liệu kỹ thuật công khai nhằm tra cứu và so sánh sơ bộ. Bản tóm tắt không thay thế bảng dữ liệu hiện hành được nhà sản xuất chứng nhận. Kiểm tra phiên bản và giới hạn thiết kế trước khi sử dụng.