Tóm tắt tài liệu kỹ thuật
AK-400
Engineering summary from PDF text extraction for AK-400. Verify every value with the OEM datasheet.
Summary
Product identification
The AK Series are Low Energy Brackish Water RO Elements from the A-Series family of proprietary thin-film reverse osmosis elements, characterized by high flux and high sodium chloride rejection. These elements allow significant energy savings, achieving good rejection at operating pressures as low as 100 psi (689 kPa).
- Membrane: A-series, thin-film membrane (TFM)
| Model | Outer wrap | Part Number |
|---|---|---|
| AK2540TM | Tape | 1206802 |
| AK4040C | Cage | 1223696 |
| AK4040FM | Fiberglass | 3039082 |
| AK4040TM | Tape | 3039149 |
| AK8040F | Fiberglass | 3039160 |
| AK8040F 400 | Fiberglass | 3039161 |
| AK8040F 440 | Fiberglass | 3194308 |
Note: AK4040C elements do not feature brine seal.
Product water
Performance is based on testing conditions of 500ppm NaCl solution at 115psi (793kPa) operating pressure, 77°F (25°C), pH 7.5 and 15% recovery. Average salt rejection is after 24 hours operation. Individual flow rate may vary ±20%.
| Model | Average Permeate Flow gpd (m³/day) | Average NaCl Rejection | Minimum NaCl Rejection |
|---|---|---|---|
| AK2540TM | 750 (2.8) | 99.0% | 98.0% |
| AK4040C | 2,300 (8.7) | 99.0% | 98.0% |
| AK4040FM | 2,200 (8.3) | 99.0% | 98.0% |
| AK4040TM | 2,200 (8.3) | 99.0% | 98.0% |
| AK8040F | 10,000 (37.9) | 99.0% | 98.0% |
| AK8040F 400 | 11,000 (41.6) | 99.0% | 98.0% |
| AK8040F 440 | 12,000 (45.4) | 99.0% | 98.0% |
Operating limits
- Typical Operating Pressure: 100 psi (689 kPa)
- Typical Operating Flux: 10-20 GFD (15-35 LMH)
- Maximum Operating Pressure: 600 psi (4,136 kPa)
- Maximum Temperature:
- Continuous operation: 122°F (50°C)
- Clean In Place (CIP): 122°F (50°C)
- pH Range:
- Optimum rejection: 7.0-7.5
- Continuous operation: 2.0-11.0
- Clean In Place (CIP): 1.0-13.0
- Maximum Pressure Drop:
- Over an element: 15 psi (103 kPa)
- Per housing: 50 psi (345 kPa)
- Chlorine Tolerance: 1,000+ ppm x hours (dechlorination recommended)
Feed water
- NTU: < 1
- SDI₁₅: < 5
Mechanical / hydraulic
Element properties and parameters are indicative numbers, specific values by element may vary within normal manufacturing tolerances.
| Model | Membrane area ft² (m²) | Type | Dimensions A, Inches (cm) | Dimensions B, Inches (cm) | Dimensions C, Inches (cm) | Boxed Weight lbs. (kg) |
|---|---|---|---|---|---|---|
| AK2540TM | 27 (2.5) | Male | 40.0 (101.6) | 0.75 (1.9) | 2.4 (6.1) | 5 (2.3) |
| AK4040C | 90 (8.4) | Female | 40.0 (101.6) | 0.625 (1.59) | 3.9 (9.9) | 9 (4) |
| AK4040FM | 85 (7.9) | Male | 40.0 (101.6) | 0.75 (1.9) | 3.9 (9.9) | 9 (4) |
| AK4040TM | 85 (7.9) | Male | 40.0 (101.6) | 0.75 (1.9) | 3.9 (9.9) | 9 (4) |
| AK8040F | 365 (33.9) | Female | 40.0 (101.6) | 1.125 (2.86) | 7.9 (20.1) | 35 (16) |
| AK8040F 400 | 400 (37.2) | Female | 40.0 (101.6) | 1.125 (2.86) | 7.9 (20.1) | 35 (16) |
| AK8040F 440 | 440 (40.9) | Female | 40.0 (101.6) | 1.125 (2.86) | 7.9 (20.1) | 35 (16) |
The document refers to "Element Dimensions Diagram – Female" and "Element Dimensions Diagram – Male" for visual representation. The AK4040C dimension 'B' includes the interconnector.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. For contractual data, always refer to the specific OEM PDF revision used on your project.
Official datasheet (PDF)
Nội dung tổng hợp từ tài liệu kỹ thuật công khai nhằm tra cứu và so sánh sơ bộ. Bản tóm tắt không thay thế bảng dữ liệu hiện hành được nhà sản xuất chứng nhận. Kiểm tra phiên bản và giới hạn thiết kế trước khi sử dụng.