Tóm tắt tài liệu kỹ thuật

8040-X201-UWA

Engineering summary from PDF text extraction for 8040-X201-UWA. Verify every value with the OEM datasheet.

Summary

Product identification

  • Series: 8" X-20 Low Fouling RO Element Series
  • Model: 8040-X201-UWA
  • Membrane Type: X20 Fully Aromatic Polyamide-Urea Advanced Composite Membrane
  • Configuration: Spiral Wound, Fiberglass Outer Wrap with FoulGuard Technology
  • Core Tube: TriSep Style
  • Active Membrane Area: 400 ft² (37.2 m²)

Operating limits

  • Recommended Applied Pressure: 100 - 300 psi (7 - 21 bar)
  • Maximum Applied Pressure: 600 psi (41 bar)
  • Recommended Operating Temperature: 35 - 113°F (2 - 45°C)
  • Feedwater pH Range: 2 - 11 continuous
  • Chlorine Tolerance: <0.1 ppm
  • Maximum SDI (15 minutes): 5.0
  • Maximum Turbidity: 2 NTU
  • Maximum Feed Flow: 80 GPM (18 m³/hr)
  • Minimum Brine Flow/Permeate Flow Ratio: 5:1

Feed water

Performance is based on the following test conditions:

  • NaCl Concentration: 2,000.0 ppm
  • Applied Pressure: 225.0 psi
  • Temperature: 25°C
  • Recovery: 15%
  • pH: 8.0
  • Operation Time: 30 minutes

Product water

  • Permeate Flow: 10,400 GPD (39.0 m³/day)
    • Note: Permeate flow is clean water flux at standard conditions. Not applicable for all feedwater conditions. Individual element's permeate flow may vary +/- 15%.
  • Average Salt Rejection: 98.50%
  • Minimum Salt Rejection: 99.50%

Mechanical / hydraulic

  • Length (A): 40.0 inches (1,016 mm)
  • Diameter (B): 7.9 inches (200 mm)
  • Permeate Tube (C): 1.50 inches (38.1 mm)
  • Element Weight: 45 lbs (20 kg)
  • Feed Spacer: 0.028" thick diamond spacer

Disclaimer: This summary is based solely on the extracted text and may not include all figures, footnotes, or the latest revisions found in the official PDF datasheet. Contractual data must match the OEM PDF revision used on the project.