Tóm tắt tài liệu kỹ thuật
8040-ACM5-UWAN
Engineering summary from PDF text extraction for 8040-ACM5-UWAN. Verify every value with the OEM datasheet.
Summary
Product identification
- Model: 8040-ACM5-UWAN
- Series: 8" ACM-LP Low Pressure RO Element Series
- Membrane Type: ACM-LP Fully Aromatic Polyamide Low Pressure Advanced Composite
- Configuration: Spiral Wound, Fiberglass Outer Wrap
- Core Tube: TriSep Style
Operating limits
- Recommended Applied Pressure: 50 - 300 psi (3 - 21 bar)
- Maximum Applied Pressure: 600 psi (41 bar)
- Recommended Operating Temperature: 35 - 113°F (2 - 45°C)
- Maximum Feed Flow: 80 GPM (18 m³/hr)
- Minimum Brine Flow/Permeate Flow Ratio: 5:1
- Feedwater pH Range: 2 - 11 continuous
- Chlorine Tolerance: <0.1 ppm
Feed water
- Maximum SDI (15 minutes): 4.0
- Maximum Turbidity: 1 NTU
Product water
Performance is based on the following test conditions: 2,000.00 ppm NaCl, 150.00 psi, 25°C, 15% recovery, pH 8.00, 30 minutes operation.
- Active Membrane Area: 400 ft² (37.2 m²)
- Permeate flow (for 8040-ACM5-UWAN): 12,500 GPD (47.0 m³/day)*
- Average Salt Rejection: 97.50%
- Minimum Salt Rejection: 98.50%
* Permeate flow is clean water flux at standard conditions. Not applicable for all feedwater conditions. Individual element's permeate flow may vary +/- 15%.
Mechanical / hydraulic
- Element Weight: 50 lbs (23 kg)
- Length (A): 40.00 inches (1,016 mm)
- Diameter (B): 7.9 inches (200 mm)
- Permeate Tube (C): 1.50 inches (38.1 mm)
- Feed Spacer: 0.028" thick diamond spacer