Quay lại TriSep Membranes
MANN+HUMMEL logo

Tóm tắt tài liệu kỹ thuật

8040-ACM5-TSA

Engineering summary from PDF text extraction for 8040-ACM5-TSA. Verify every value with the OEM datasheet.

Summary

Product Identification

  • Product Series: 8" ACM-LP Low Pressure RO Element Series
  • Model: 8040-ACM5-TSA
  • Membrane Type: ACM-LP Fully Aromatic Polyamide Low Pressure Advanced Composite
  • Configuration: Spiral Wound, Fiberglass Outer Wrap
  • Core Tube: TriSep Style Core Tube
  • Active Membrane Area: 365 ft² (33.5 m²)

Mechanical / Hydraulic

  • Element Weight: 45 lbs (20 kg)
  • Length (A): 40.0 inches (1,016 mm)
  • Diameter (B): 7.9 inches (200 mm)
  • Permeate Tube (C): 1.50 inches (38.1 mm)
  • Feed Spacer: 0.031" thick diamond spacer

Operating Limits

  • Recommended Applied Pressure: 50 - 300 psi (3 - 21 bar)
  • Maximum Applied Pressure: 600 psi (41 bar)
  • Recommended Operating Temperature: 35 - 113°F (2 - 45°C)
  • Feedwater pH Range: 2 - 11 continuous
  • Chlorine Tolerance: <0.1 ppm
  • Maximum Feed Flow: 80 GPM (18 m³/hr)
  • Minimum Brine Flow/Permeate Flow Ratio: 5:1

Feed Water

  • Maximum SDI (15 minutes): 5.0
  • Maximum Turbidity: 1 NTU

Product Water

Performance is based on the following test conditions: 2,000.0 ppm NaCl, 150.0 psi, 25°C, 15% recovery, pH 8.0, 30 minutes operation.

  • Permeate Flow: 11,900 GPD (45.0 m³/day)
  • Average Salt Rejection: 97.50%
  • Minimum Salt Rejection: 98.50%

Note: Permeate flow is clean water flux at standard conditions. Individual element's permeate flow may vary +/- 15%.


Disclaimer: This summary is based on the provided text extract. It may not include all figures, footnotes, or the most recent revisions found in the complete OEM PDF datasheet. Contractual data must match the specific OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Nội dung tổng hợp từ tài liệu kỹ thuật công khai nhằm tra cứu và so sánh sơ bộ. Bản tóm tắt không thay thế bảng dữ liệu hiện hành được nhà sản xuất chứng nhận. Kiểm tra phiên bản và giới hạn thiết kế trước khi sử dụng.