Quay lại TriSep Membranes
MANN+HUMMEL logo

Tóm tắt tài liệu kỹ thuật

8040-ACM4-TSA

Engineering summary from PDF text extraction for 8040-ACM4-TSA. Verify every value with the OEM datasheet.

Summary

Product identification

  • Model: 8040-ACM4-TSA
  • Series: 8" ACM-LP Low Pressure RO Element Series
  • Membrane Type: ACM-LP Fully Aromatic Polyamide Low Pressure Advanced Composite
  • Configuration: Spiral Wound, Fiberglass Outer Wrap

Operating limits

  • Recommended Applied Pressure: 50 - 300 psi (3 - 21 bar)
  • Maximum Applied Pressure: 600 psi (41 bar)
  • Recommended Operating Temperature: 35 - 113°F (2 - 45°C)
  • Feedwater pH Range: 2 - 11 continuous
  • Chlorine Tolerance: <0.1 ppm
  • Maximum Feed Flow: 80 GPM (18 m³/hr)
  • Minimum Brine Flow/Permeate Flow Ratio: 5:1
  • Maximum SDI (15 minutes): 5.0
  • Maximum Turbidity: 1 NTU

Performance

Performance is based on the following test conditions: 2,000.0 ppm NaCl, 225.0 psi, 25°C, 15% recovery, pH 8.0, 30 minutes operation.

  • Permeate Flow: 14,600 GPD (55.0 m³/day)
    • Note: Permeate flow is clean water flux at standard conditions. Individual element's permeate flow may vary +/- 15%.
  • Average Salt Rejection: 98.00%
  • Minimum Salt Rejection: 99.00%

Mechanical / hydraulic

  • Element Weight: 45 lbs (20 kg)
  • Length (A): 40.0 inches (1,016 mm)
  • Diameter (B): 7.9 inches (200 mm)
  • Permeate Tube (C): 1.50 inches (38.1 mm)
  • Core Tube Style: TriSep Style
  • Feed Spacer: 0.031" thick diamond spacer
  • Active Membrane Area: 365 ft² (33.5 m²)

Disclaimer: This summary is based on the provided text extract. The full OEM PDF datasheet may contain additional figures, footnotes, or more recent revisions. Contractual data for any project must match the specific OEM PDF revision used on that project.

Official datasheet (PDF)

PDF datasheet

Nội dung tổng hợp từ tài liệu kỹ thuật công khai nhằm tra cứu và so sánh sơ bộ. Bản tóm tắt không thay thế bảng dữ liệu hiện hành được nhà sản xuất chứng nhận. Kiểm tra phiên bản và giới hạn thiết kế trước khi sử dụng.