Tóm tắt tài liệu kỹ thuật
8040-ACM3-TSAN
Engineering summary from PDF text extraction for 8040-ACM3-TSAN. Verify every value with the OEM datasheet.
Summary
Product identification
- Model: 8040-ACM3-TSAN
- Series: 8" ACM RO Element Series
- Membrane Type: ACM Fully Aromatic Polyamide Advanced Composite Membrane
- Configuration: Spiral Wound, Fiberglass Outer Wrap
- Active Membrane Area: 365 ft² (33.5 m²)
Operating limits
- Recommended Applied Pressure: 100 - 300 psi (7 - 21 bar)
- Maximum Applied Pressure: 600 psi (41 bar)
- Recommended Operating Temperature: 35 - 113°F (2 - 45°C)
- Feedwater pH Range: 2 - 11 continuous
- Chlorine Tolerance: <0.1 ppm
- Maximum Feed Flow: 80 GPM (18 m³/hr)
- Minimum Brine Flow/Permeate Flow Ratio: 5:1
- Maximum SDI (15 minutes): 5.0
- Maximum Turbidity: 1 NTU
Product water
- Permeate Flow: 11,000 GPD (41.0 m³/day)
- Note: Permeate flow is clean water flux at standard conditions. Not applicable for all feedwater conditions. Individual element's permeate flow may vary ± 15%.
- Average Salt Rejection: 98.50%
- Minimum Salt Rejection: 99.20%
Mechanical / hydraulic
- Element Weight: 45 lbs (20 kg)
- Length: 40.0 inches (1,016 mm)
- Diameter: 7.9 inches (200 mm)
- Permeate Tube: 1.50 inches (38.1 mm)
- Core Tube: TriSep Style
- Feed Spacer: 0.031" thick diamond spacer
Performance Test Conditions
Performance is based on the following test conditions:
- NaCl Concentration: 2,000.0 ppm
- Applied Pressure: 225.0 psi
- Temperature: 25°C
- Recovery: 15%
- pH: 8.0
- Operation Duration: 30 minutes
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.