Tóm tắt tài liệu kỹ thuật
4040-X201-TSF
Engineering summary from PDF text extraction for 4040-X201-TSF. Verify every value with the OEM datasheet.
Summary
Product identification
- Series: 4" X-20 Low Fouling RO Element Series
- Model: 4040-X201-TSF
- Membrane Type: X20 Fully Aromatic Polyamide-Urea Advanced Composite Membrane
- Configuration: Spiral Wound, Fiberglass Outer Wrap with FoulGuard Technology
- Active Membrane Area: 85 ft² (7.9 m²)
Operating limits
- Recommended Applied Pressure: 100 - 300 psi (7 - 21 bar)
- Maximum Applied Pressure: 600 psi (41 bar)
- Recommended Operating Temperature: 35 - 113°F (2 - 45°C)
- Feedwater pH Range: 2 - 11 continuous
- Chlorine Tolerance: <0.1 ppm
- Maximum Feed Flow: 20 GPM (4.5 m³/hr)
- Minimum Brine Flow/Permeate Flow Ratio: 5:1
- Maximum SDI (15 minutes): 5.0
- Maximum Turbidity: 2 NTU
Feed water
- pH Range: 2 - 11 continuous
- Chlorine Tolerance: <0.1 ppm
- Maximum SDI (15 minutes): 5.0
- Maximum Turbidity: 2 NTU
Product water
- Permeate Flow: 2,400 GPD (9.0 m³/day)
- Average Salt Rejection: 98.50%
- Minimum Salt Rejection: 99.50%
- Note on permeate flow: Permeate flow is clean water flux at standard conditions. Not applicable for all feedwater conditions. Individual element's permeate flow may vary +/- 15%.
Mechanical / hydraulic
- Core Tube Style: Filmtec Style Core Tube
- Element Weight: 15 lbs (7 kg)
- Length (A): 40.0 inches (1,016 mm)
- Diameter (B): 4.0 inches (101 mm)
- Permeate Tube (C) Diameter: 0.75 inches (19.1 mm)
- Feed Spacer: 0.031" thick diamond spacer
Performance Test Conditions
Performance is based on the following test conditions:
- 2,000.0 ppm NaCl
- 225.0 psi
- 25°C
- 15% recovery
- pH 8.0
- 30 minutes operation
Disclaimer
This summary is based solely on the provided text extract. It may not include all figures, footnotes, or the latest revisions present in the official PDF datasheet. For contractual data, always refer to the specific OEM PDF revision used for the project.
Official datasheet (PDF)
Nội dung tổng hợp từ tài liệu kỹ thuật công khai nhằm tra cứu và so sánh sơ bộ. Bản tóm tắt không thay thế bảng dữ liệu hiện hành được nhà sản xuất chứng nhận. Kiểm tra phiên bản và giới hạn thiết kế trước khi sử dụng.