Quay lại Toray Membranes
Toray logo

Tóm tắt tài liệu kỹ thuật

TM720L-400

Engineering summary from PDF text extraction for TM720L-400. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product Type: Low-Pressure-Brackish Water RO Elements
  • Membrane Type: Cross Linked Fully Aromatic Polyamide Composite
  • Available Models: TM720L-400, TM720L-430, TM720L-440

Operating limits

  • Maximum Operating Pressure: 600 psi (4.1 MPa)
  • Maximum Feed Water Temperature: 113˚F (45 ˚C)
  • Maximum Feed Water SDI₁₅: 5
  • Feed Water Chlorine Concentration: Not Detectable
  • Feed Water pH Range, Continuous Operation: 2-11
  • Feed Water pH Range, Chemical Cleaning: 1-12
  • Maximum Pressure Drop per Element: 20 psi (0.14 MPa)
  • Maximum Pressure Drop per Vessel: 60 psi (0.4 MPa)

Feed water

Performance data is based on the following test conditions:

  • Feed Water Pressure: 150 psi (1.03 MPa)
  • Feed Water Temperature: 77°F (25℃)
  • Feed Water Concentration: 2,000 mg/l NaCl
  • Recovery Rate: 15%
  • Feed Water pH: 7

Product performance

  • Minimum Salt Rejection: 99.0%
TypeProduct Flow Rate gpd (m³/d)Feed Spacer Thickness milSalt Rejection %Membrane Area ft² (m²)Diameter Inch
TM720L-4006,800 (25.8)2899.5400 (37)8”
TM720L-4307,300 (27.7)2899.5430 (40)8”
TM720L-4407,500 (28.4)3199.5440 (41)8”

Mechanical / hydraulic

  • All dimensions are shown in Inches (millimeter).
  • Element Length: 40 (1,016)
  • Element Diameter: 7.9 (201) (also listed as 8” in the product performance table)
  • Permeate Tube Diameter: 1.125 (29)

Operating information

  • Elements are wet tested, treated with a 1% by weight percent sodium bisulfite storage solution, and then vacuum packed in oxygen barrier bags, or treated with tested feed water solution and vacuum packed with deoxidant inside.
  • For short term storage, shipment, or system shutdown, elements should be immersed in a protective solution containing 500 - 1,000 ppm of sodium bisulfite (food grade) dissolved in permeate.
  • Permeate from the first hour of operation shall be discarded.
  • The customer is fully responsible for the effects of chemicals that are incompatible with the elements. Their use will void the element Limited Warranty.

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Nội dung tổng hợp từ tài liệu kỹ thuật công khai nhằm tra cứu và so sánh sơ bộ. Bản tóm tắt không thay thế bảng dữ liệu hiện hành được nhà sản xuất chứng nhận. Kiểm tra phiên bản và giới hạn thiết kế trước khi sử dụng.