Quay lại Toray Membranes
Toray logo

Tóm tắt tài liệu kỹ thuật

SUL-G10

Engineering summary from PDF text extraction for SUL-G10. Verify every value with the OEM datasheet.

Summary

Product identification

  • Model: SUL-G10 Small system and energy saving RO element
  • Membrane Type: Cross Linked Fully Aromatic Polyamide Composite
  • Element Configuration: Spiral Wound

Performance Specification

The following performance is based on specific test conditions:

  • Salt Rejection: 99.5 % (99.0 % minimum*)
  • Product Flow Rate: 6.5 m³/day (1700 gpd) (5.5 m³/day (1450 gpd) minimum*)

*For any single element

Test Conditions:

  • Feed Water Pressure: 0.75 MPa (110 psi)
  • Feed Water Temperature: 25 °C (77 °F)
  • Feed Water Concentration: 500 mg/L as NaCl
  • Brine Flow Rate: 20 L/min. (5.3 gpm)
  • Feed Water pH: 6.5

Operating limits

  • Maximum Feed Water Pressure: 4.1 MPa (600 psi)
  • Maximum Feed Water Temperature: 40 °C (104 °F)
  • Feed Water pH Range, Continuous Operation: 3 – 9
  • Feed Water pH Range, Chemical Cleaning: 2 – 11
  • Feed Water Turbidity (SDI): 4 (measured according to ASTM D4189)
  • Recommended Feed Water Pressure: 1.0 MPa (150 psi)
  • Recommended Feed Water Temperature: 35 °C (95 °F)
  • Recommended Feed Flow Rate per Vessel: 50 L/min. (13 gpm)
  • Recommended Brine Flow Rate per Vessel: 10 L/min. (2.6 gpm)
  • Recommended Brine/Permeate Flow Ratio: 6 (at last element)
  • Recommended Pressure Drop (per Element): 0.10 MPa (14 psi)
  • Recommended Pressure Drop (per Vessel): 0.20 MPa (29 psi)

Mechanical / Hydraulic

  • Membrane Surface Area: Nominal 7 m² (75 ft²)
  • Dimensions: See the official PDF for exact tabulated values and diagrams; all dimensions are shown in millimeters.

Disclaimer: This summary is based on the provided text extraction and may not include all figures, footnotes, or the latest revisions. Contractual data for any project must match the OEM PDF revision used on that specific project.

Official datasheet (PDF)

PDF datasheet

Nội dung tổng hợp từ tài liệu kỹ thuật công khai nhằm tra cứu và so sánh sơ bộ. Bản tóm tắt không thay thế bảng dữ liệu hiện hành được nhà sản xuất chứng nhận. Kiểm tra phiên bản và giới hạn thiết kế trước khi sử dụng.