SEA5-4021

Engineering summary from PDF text extraction for SEA5-4021. Verify every value with the OEM datasheet.

Summary

Product Identification

  • Model: SEA5-4021
  • Description: Low Energy, Excellent Rejection, Very High Productivity - Sea Water Element
  • Configuration: Spiral Wound
  • Membrane Polymer: Composite Polyamide
  • Brine Spacer Material: Polypropylene

Specifications

  • Permeate Flow: 700 gpd (2.6 m³/d)
  • Nominal Salt Rejection: 99.6% (99.4% minimum)
  • Nominal Membrane Area: 35 ft² (3.2 m²)

Test Conditions

(After 30 min of operation)

  • NaCl Solution: 32000 ppm
  • Applied Pressure: 800 psi (56 bar)
  • Operating Temperature: 77 °F (25 °C)
  • Permeate Recovery: 10%
  • pH Range: 6.5 ÷ 7.0

Operating Limits

  • Maximum Operating Pressure: 1000 psi (69 bar)
  • Maximum Operating Temperature: 113 °F (45 °C)
  • Maximum Pressure Drop: 10 psi (0.7 bar)
  • Maximum Feed Flow: 12 gpm (45.4 lpm)
  • Maximum Feed Chlorine Concentration: <0.1 ppm
  • Maximum Feedwater SDI (15min): 5.0
  • Maximum Feedwater Turbidity: 1.0 NTU
  • Feedwater pH: 3.0 ÷ 10.0
  • Minimum ratio of concentrate to permeate flow for any element: 5:1

Mechanical / Hydraulic

Dimensions

  • Total Length (A): 21.0 inches (533.4 mm)
  • Element Diameter (B): 3.95 inches (100.3 mm)
  • Permeate Connection Diameter (C): 0.75 inches (19.1 mm)
  • Core Tube Extension Diameter (DF) Feed Side: 1.2 inches (30.5 mm)
  • Core Tube Extension Diameter (DC) Conc. Side: 1.2 inches (30.5 mm)
  • Weight: 4 lbs (1.8 Kg)

Guidelines

  • Permeate obtained from the first hour of operation should be discarded.
  • Avoid static permeate-side backpressure at all times.
  • These membranes may be subject to drinking water application restrictions in some countries; check the application status before use and sale.
  • For element loading, use only glycerine to lubricate o-rings and brine seal.
  • The presence of free chlorine and other oxidizing agents will cause membrane failure, and the damage is not covered under warranty.

Disclaimer: This summary is based on the provided text extraction. It may not include all figures, footnotes, or the most recent revisions present in the official PDF datasheet. Contractual data must match the specific OEM PDF revision used on the project.