Tóm tắt tài liệu kỹ thuật
LOW3-4040-XL
Engineering summary from PDF text extraction for LOW3-4040-XL. Verify every value with the OEM datasheet.
Summary
Product Identification
- Model: LOW3-4040-XL
- Type: Extra Area - Low Energy, Excellent Productivity - Brackish Water Element
- Configuration: Spiral Wound
- Membrane Polymer: Composite Polyamide
- Brine Spacer Material: Polypropylene
Product Water
- Permeate Flow: 3700 gpd (14 m³/d)
- Salt Rejection: 98.8% nominal (98.0% minimum)
Performance Test Conditions
Performance specifications are based on the following test conditions (after 30 min of operation):
- NaCl Solution: 1500 ppm
- Applied Pressure: 150 psi (10.3 bar)
- Operating Temperature: 77 °F (25 °C)
- Permeate Recovery: 15%
- Permeate pH: 6.5 ÷ 7.0
Mechanical / Hydraulic
- Nominal Membrane Area: 105 ft² (9.8 m²)
- Dimensions:
- Total Length (A): 40.0 inches (1016 mm)
- ATD Diameter (B): 3.95 inches (100.3 mm)
- Connection Diameter (C): 0.75 inches (19.1 mm)
- Core Tube Extension Feed Side (DF): 1.05 inches (26.7 mm)
- Core Tube Extension Concentrate Side (DC): 1.05 inches (26.7 mm)
- Weight: 8 lbs (3.6 Kg)
Operating Limits
- Operating Pressure: 300 psi (20.7 bar)
- Temperature: 113 °F (45 °C)
- Pressure Drop: 10 psi (0.7 bar)
- Feed Flow: 16 gpm (3.6 m³/h)
- Chlorine Concentration: <0.1 ppm
- Feedwater pH Range: 3.0 ÷ 10.0
- Feedwater SDI (15min): 5.0
- Feedwater Turbidity: 1.0 NTU
- Minimum ratio of concentrate to permeate flow for any element: 5:1
Notices and Guidelines
- Permeate flow for individual elements may vary ±15 percent.
- Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite and 10% propylene glycol solution.
- Permeate obtained from the first hour of operation should be discarded.
- Avoid static permeate-side backpressure at all times.
- These membranes may be subject to drinking water application restrictions in some countries; please check the application status before use and sale.
- For element loading, use only glycerine to lubricate o-rings and brine seal.
- The customer is fully responsible for the effects of incompatible chemicals on elements. The presence of free chlorine and other oxidizing agents will cause membrane failure, and this damage is not covered under warranty.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions found in the official PDF datasheet. Contractual data must always match the OEM PDF revision used on the project.
Official datasheet (PDF)
Nội dung tổng hợp từ tài liệu kỹ thuật công khai nhằm tra cứu và so sánh sơ bộ. Bản tóm tắt không thay thế bảng dữ liệu hiện hành được nhà sản xuất chứng nhận. Kiểm tra phiên bản và giới hạn thiết kế trước khi sử dụng.