Summary

Product identification

  • Model: LOW2-4014
  • Type: Low Energy, Excellent Rejection - Brackish Water Element
  • Configuration: Spiral Wound
  • Membrane Polymer: Composite Polyamide
  • Brine Spacer Material: Polypropylene

Performance

  • Nominal Permeate Flow: 370 gpd (1,4 m³/d)
  • Nominal Salt Rejection: 99,4% (99,0% minimum)
  • Nominal Membrane Area: 19 ft² (1,8 m²)

Test Conditions

(After 30 min of operation)

  • NaCl Solution: 1500 ppm
  • Applied Pressure: 150 psi (10,3 bar)
  • Operating Temperature: 77 °F (25 °C)
  • Permeate Recovery: 10%
  • pH Range: 6,5 ÷ 7,0

Mechanical / Hydraulic

  • Total Length (A): 14.0 inches (355,6 mm)
  • Diameter (B): 3.95 inches (100,3 mm)
  • Connection Diameter (C): 0.75 inches (19,1 mm)
  • Core Tube Extension Feed Side (DF): 1.2 inches (30,5 mm)
  • Core Tube Extension Conc. Side (DC): 1.2 inches (30,5 mm)
  • Weight: 3 lbs (1,4 Kg)

Operating limits

  • Maximum Operating Pressure:
    • Fiberglassed: 600 psi (41,4 bar)
    • Tape Wrapped: 300 psi (20,7 bar)
  • Maximum Temperature: 113 °F (45 °C)
  • Maximum Pressure Drop: 10 psi (0,7 bar)
  • Maximum Feed Flow: 12 gpm (45,4 lpm)
  • Maximum Feed Chlorine Concentration: <0,1 ppm
  • Maximum Feedwater SDI (15min): 5,0
  • Maximum Feedwater Turbidity: 1,0 NTU
  • Feedwater pH: 3,0 ÷ 10,0
  • Minimum ratio of concentrate to permeate flow for any element: 5:1

Other Operating Information

  • Minimum permeate flow for individual elements is 15 percent below listed flow.
  • Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite.
  • Permeate obtained from the first hour of operation should be discarded.
  • Avoid static permeate-side backpressure at all times.
  • These membranes may be subject to drinking water application restrictions in some countries; please check the application status before use and sale.
  • For element loading, use only glycerine to lubricate O-rings and brine seal.
  • The presence of free chlorine and other oxidizing agents will cause membrane failure; this damage is not covered under warranty.