Tóm tắt tài liệu kỹ thuật

LOW1-4040-XL

Engineering summary from PDF text extraction for LOW1-4040-XL. Verify every value with the OEM datasheet.

Summary

Product identification

  • Model: LOW1-4040-XL
  • Type: Extra Area - Low Energy, Very High Rejection - Brackish Water Element
  • Configuration: Spiral Wound
  • Membrane Polymer: Composite Polyamide
  • Brine Spacer Material: Polypropylene
  • Nominal Membrane Area: 105 ft² (9.8 m²)

Product water

  • Permeate Flow: 3300 gpd (12.5 m³/d)
  • Salt Rejection: 99.3% nominal (99.0% minimum)

Test Conditions (for listed performance)

  • NaCl Solution: 1500 ppm
  • Applied Pressure: 150 psi (10.3 bar)
  • Operating Temperature: 77 °F (25 °C)
  • Permeate Recovery: 15%
  • pH Range (after 30 min operation): 6.5 ÷ 7.0

Operating limits

  • Maximum Operating Pressure: 300 psi (20.7 bar)
  • Maximum Operating Temperature: 113 °F (45 °C)
  • Maximum Pressure Drop: 10 psi (0.7 bar)
  • Maximum Feed Flow: 16 gpm (3.6 m³/h)
  • Feedwater pH Range: 3.0 ÷ 10.0
  • Minimum ratio of concentrate to permeate flow for any element: 5:1

Feed water

  • Maximum Chlorine Concentration: <0.1 ppm
  • Maximum Feedwater SDI (15 min): 5.0
  • Maximum Feedwater Turbidity: 1.0 NTU

Mechanical / hydraulic

  • Total Length: 40.0 inches (1016 mm)
  • ATD Diameter: 3.95 inches (100.3 mm)
  • Connection Diameter: 0.75 inches (19.1 mm)
  • Core Tube Extension Feed Side: 1.05 inches (26.7 mm)
  • Core Tube Extension Conc. Side: 1.05 inches (26.7 mm)
  • Weight: 8 lbs (3.6 Kg)

Important Operating Guidelines

  • Permeate flow for individual elements may vary ±15 percent.
  • Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite and 10% propylene glycol solution.
  • Permeate obtained from first hour of operation should be discarded.
  • Avoid static permeate-side backpressure at all times.
  • These membranes may be subject to drinking water application restrictions in some countries; please check the application status before use and sale.
  • For element loading, use only glycerine to lubricate o-rings and brine seal.
  • The presence of free chlorine and other oxidizing agents will cause membrane failure, and this damage is not covered under warranty.

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions present in the official PDF datasheet. Contractual data must always match the specific OEM PDF revision used on the project.