Quay lại OLTREMARE
OLTREMARE logo

Tóm tắt tài liệu kỹ thuật

FOUL1-2540

Engineering summary from PDF text extraction for FOUL1-2540. Verify every value with the OEM datasheet.

Summary

Product identification

  • Model: FOUL1-2540
  • Type: Low Fouling, Neutral Charged - Brackish Water Element
  • Configuration: Spiral Wound
  • Membrane Polymer: Composite Polyamide
  • Brine Spacer Material: Polypropylene

Nominal Performance

Based on the following test conditions:

  • Solution: 1500 ppm NaCl
  • Applied Pressure: 225 psi (15.5 bar)
  • Operating Temperature: 77 °F (25 °C)
  • Recovery: 10%
  • Permeate pH (After 30 min of operation): 6.5 ÷ 7.0

Performance specifications:

  • Nominal Permeate Flow: 650 gpd (2.5 m³/d)
  • Salt Rejection: 98.0% minimum
  • Nominal Membrane Area: 28 ft² (2.6 m²)

Mechanical / hydraulic

Dimensions:

  • Total Length (A): 40.0 inches (1016 mm)
  • Diameter (B): 2.4 inches (61 mm)
  • Connection Diameter (C): 0.75 inches (19.1 mm)
  • Core Tube Extension Feed Side (DF): 1.2 inches (30.5 mm)
  • Core Tube Extension Conc. Side (DC): 1.2 inches (30.5 mm)
  • Weight: 4 lbs (1.8 Kg)

Operating limits

  • Operating Pressure:
    • Fiberglassed: 600 psi (41.4 bar)
    • Tape Wrapped: 300 psi (20.7 bar)
  • Temperature: 113 °F (45 °C)
  • Pressure Drop: 10 psi (0.7 bar)
  • Maximum Flow: 6 gpm (23 lpm)
  • Feedwater pH Range: 3.0 ÷ 10.0
  • Minimum ratio of concentrate to permeate flow for any element: 5:1

Feed water

  • Chlorine Concentration: <0.1 ppm
  • SDI (15min): 5.0
  • Turbidity: 1.0 NTU

Product water

  • Minimum permeate flow for individual elements 15 percent below listed flow.
  • Permeate obtained from the first hour of operation should be discarded.
  • Avoid static permeate-side backpressure at all times.

Handling and Storage Notes

  • Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite and 10% propylene glycol solution.
  • For element loading, use only glycerine to lubricate o-rings and brine seal.
  • The presence of free chlorine and other oxidizing agents will cause membrane failure, and the damage is not covered under warranty.