Tóm tắt tài liệu kỹ thuật
AsHR-4040
Engineering summary from PDF text extraction for AsHR-4040. Verify every value with the OEM datasheet.
Summary
Product identification
- Model: AsHR-4040
- Configuration: Spiral Wound
- Type: High Arsenic Removal - Nanofiltration Element
- Membrane Polymer: Composite Polyamide
- Brine Spacer Material: Polypropylene
Specifications
- Nominal Membrane Area: 85 ft² (7.9 m²)
- Permeate Flow: 2200 gpd (8.3 m³/d)
- Stabilized Salt Rejection: >97%
- Arsenic Removal (minimum): 97%
Operating limits
- Maximum Operating Temperature: 113 °F (45 °C)
- Maximum Operating Pressure:
- Fiberglassed: 600 psi (41.4 bar)
- Tape Wrapped: 300 psi (20.7 bar)
- Maximum Feed Flow: 16 gpm (3.6 m³/h)
- Maximum Chlorine Concentration: <0.1 ppm
- Maximum Feedwater SDI (15min): 5.0
- Maximum Feedwater Turbidity: 1.0 NTU
- Maximum Pressure Drop: 10 psi (0.7 bar)
- Feedwater pH Range: 3.0 ÷ 10.0
- Minimum Ratio of Concentrate to Permeate Flow: 5:1 for any element
Test Conditions (Permeate Flow and Rejection)
- Operating Temperature: 77 °F (25 °C)
- Permeate Recovery: 15%
- pH Range: 6.5 ÷ 7.0
- Solution: MgSO₄ 2000 ppm
- Applied Pressure: 70 psi (4.8 bar)
Mechanical / hydraulic
- Total Length (A): 40.0 inches (1016 mm)
- ATD Diameter (B): 3.95 inches (100.3 mm)
- Connection Diameter (C): 0.75 inches (19.1 mm)
- Core Tube Extension: 1.05 inches (26.7 mm)
- Weight: 8 lbs (3.6 Kg)
Operational Guidelines and Notices
- Permeate obtained from the first hour of operation should be discarded.
- Avoid static permeate-side backpressure at all times.
- These membranes may be subject to drinking water application restrictions in some countries; check application status before use and sale.
- For element loading, use only glycerine to lubricate o-rings and brine seal.
- Permeate flow for individual elements may vary +35% or -20%.
- Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite.
- Free chlorine and other oxidizing agents will cause membrane failure, and such damage is not covered under warranty.
Disclaimer: This summary is based on text extracted from a PDF datasheet. This extraction may miss figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Nội dung tổng hợp từ tài liệu kỹ thuật công khai nhằm tra cứu và so sánh sơ bộ. Bản tóm tắt không thay thế bảng dữ liệu hiện hành được nhà sản xuất chứng nhận. Kiểm tra phiên bản và giới hạn thiết kế trước khi sử dụng.