Quay lại Microdyn Nadir
MANN+HUMMEL logo

Tóm tắt tài liệu kỹ thuật

FS10-FC-FUS5082

Engineering summary from PDF text extraction for FS10-FC-FUS5082. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product Name: ULTRADYN HOLLOW FIBER UF MEMBRANE MODULE
  • Model: FS10-FC-FUS5082
  • Filtration type: Ultrafiltration

Module components

  • Nozzle cap: Polysulfone (2 units)
  • Cap: Polysulfone (2 units)
  • Case: Polysulfone (1 unit)
  • O-Ring type WG-21: FPM (Fluoro rubber) (2 units)
  • Potting resin: Epoxy resin
  • See the official PDF for exact tabulated dimensions.

Membrane Characteristics

  • Membrane material: Polyethersulfone
  • Molecular cutoff: 500,000 Dalton
  • Hollow fiber inner diameter: 0.8 mm
  • Membrane area: 5.0 m²

Operating limits

  • Feed inlet pressure, max.: 0.6 MPa (This value is for room temperature.)
  • Transmembrane pressure, max.: 0.3 MPa
  • Temperature, max.: 98 °C
  • Applicable pH range: 1 ~ 13
  • Note: Applicable max. pressure depends on operating temperature. Ensure instruction manual.

Performance

  • Standard water flux: 5.3 m³/h (Initial water flux by dead end filtration with pure water under T.M.P. 0.1 MPa at 25°C)
  • Shipping water flux range: 4.4 m³/h (Initial water flux by dead end filtration with pure water under T.M.P. 0.1 MPa at 25°C)
  • Standard inlet feed flow: 3.8 m³/h (Standard condition is adjusted to 1 m/sec feed velocity. Optimum velocity differs for each application.)

Mechanical / hydraulic

  • Weight at operation: 8.5 kg
  • Weight at shipping: 2.5 kg

Connectors

  • Feed/Concentrate: 2S Ferrule
  • Permeate: 1S Ferrule

Chemical specifications

  • Standard preservative: 1000 ppm Benzoic acid

Disclaimer: This summary is generated from an extracted text segment and may not include all figures, footnotes, or the latest revisions present in the full OEM PDF datasheet. Contractual data should always match the specific OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Nội dung tổng hợp từ tài liệu kỹ thuật công khai nhằm tra cứu và so sánh sơ bộ. Bản tóm tắt không thay thế bảng dữ liệu hiện hành được nhà sản xuất chứng nhận. Kiểm tra phiên bản và giới hạn thiết kế trước khi sử dụng.