Quay lại Microdyn Nadir
MANN+HUMMEL logo

Tóm tắt tài liệu kỹ thuật

i Sep 500 PES

Engineering summary from PDF text extraction for i Sep 500 PES. Verify every value with the OEM datasheet.

Summary

Product Identification

  • Product Name: MICRODYN iSep™ 500-PES Ultrafiltration Modules
  • Date: 02/05/2020
  • Membrane Chemistry: Polyethersulfone (PES)
  • Construction: Submerged, Negative Pressure Ultrafiltration Module
  • Pore Size: 0.03 micron
  • Key Features: Vacuum-driven, backwashable, spiral-wound membrane design for high fouling water and wastewater streams. Features open feed channels, an integrated tank design, and integrated aeration.

Mechanical / Hydraulic

  • Feed Channel: 90 mil corrugated
  • Membrane Area: 27.4 m² (295 ft²)
  • Module Weight: 23 kg (50 lb)
  • Physical Dimensions (Connections):
    • Item 1 Overflow: 2.0” Grooved End Coupling
    • Item 2 Feed/Drain: 2.0” Grooved End Coupling
    • Item 3 Permeate: 1.5” Cam & Groove Coupling
    • Item 4 Air: 0.75” MNPT

Operating Limits

  • Transmembrane Pressure Range: 0.07 – 0.7 bar (1 – 10 psi)
  • Temperature Range: 1 – 45°C (34 – 113°F)
  • pH Range: 2.0 – 11.0
  • Applicable Air Scour Rate: 5.6 Nm³/hr (3.5 scfm)
  • Cleaning Chlorine Tolerance: 1,000 mg/L

Feed Water

  • Maximum Feed TSS: 1,000 mg/L
  • Maximum Feed Oil & Grease: 300 mg/L
  • Designed to handle high fouling water and wastewater streams, and can handle significantly higher solids than many standard polymeric membranes.
  • Can directly treat some of the most difficult water and wastewater streams.

Product Water

  • Consistently delivers high-quality permeate regardless of feed conditions.

Important Information

  • Start-up: An operational sequence incorporating permeate production, cleaning, and module draining steps is recommended. Refer to the iSep™ 500 Product Manual pages 10-11 for detailed procedures.
  • Cleaning: Modules must be routinely cleaned via backwash, chemically enhanced backwash (CEB), and clean-in-place (CIP). Refer to the iSep™ 500 Product Manual pages 12-15 for detailed procedures.
  • Storage: Modules must be stored appropriately to ensure proper operation and prevent membrane damage. Refer to the iSep™ 500 Product Manual pages 18-19.
  • Customizable Specialty Elements: MICRODYN-NADIR offers a range of membranes and element designs for challenging applications, including low-fouling RO, submerged UF, continuous high temperature, ultra-high pressure, and unique sanitary designs.

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions present in the complete OEM PDF datasheet. For contractual data and complete product specifications, the official OEM PDF revision used on the project must be consulted.

Official datasheet (PDF)

PDF datasheet

Nội dung tổng hợp từ tài liệu kỹ thuật công khai nhằm tra cứu và so sánh sơ bộ. Bản tóm tắt không thay thế bảng dữ liệu hiện hành được nhà sản xuất chứng nhận. Kiểm tra phiên bản và giới hạn thiết kế trước khi sử dụng.