Tóm tắt tài liệu kỹ thuật
SWC5-MAX
Engineering summary from PDF text extraction for SWC5-MAX. Verify every value with the OEM datasheet.
Summary
Product identification
- Membrane Element: SWC5 MAX
- Configuration: Spiral Wound
- Membrane Polymer: Composite Polyamide
- Membrane Active Area: 440 ft² (40.8m²)
Performance
- Permeate Flow: 9,900 gpd (37.5 m³/d)
- Salt Rejection: 99.8 % (99.7 % minimum)
- Boron Rejection (Typical): 92.0%†
The stated performance is initial (data taken after 30 minutes of operation), based on the following test conditions:
- 32,000 ppm NaCl
- 800 psi (5.5 MPa) Applied Pressure
- 77 °F (25 °C) Operating Temperature
- 10% Permeate Recovery
- 6.5 - 7.0 pH Range
- † When tested at standard test conditions with 5.0ppm Boron in feed solution.
Operating limits
- Maximum Applied Pressure: 1200 psig (8.27 MPa)
- Maximum Chlorine Concentration: < 0.1 PPM
- Maximum Operating Temperature: 113 °F (45 °C)
- pH Range, Continuous (Cleaning): 2-11 (1-13)
- Maximum Feedwater Turbidity: 1.0 NTU
- Maximum Feedwater SDI (15 mins): 5.0
- Maximum Feed Flow: 75 GPM (17.0 m³/h)
- Minimum Ratio of Concentrate to Permeate Flow for any Element: 5:1
- Maximum Pressure Drop for Each Element: 15 psi
Note: The limitations shown are for general use. For specific projects, operating at more conservative values may ensure the best performance and longest life of the membrane. See Hydranautics Technical Bulletins for more detail on operation limits, cleaning pH, and cleaning temperatures.
Mechanical / hydraulic
- A: 40.0 inches (1016 mm)
- B: 7.89 inches (200 mm)
- C: 1.125 inches (28.6 mm)
- Weight: 36 lbs. (16.4 kg)
Notices
- Permeate flow for individual elements may vary ±15 percent.
- Membrane active area may vary ±4%.
- Element weight may vary.
- All membrane elements are supplied with a brine seal, interconnector, and o-rings.
- Elements are enclosed in a sealed polyethylene bag containing less than 1.0% sodium meta-bisulfite solution, and then packaged in a cardboard box.