Summary

Product identification

  • NANO-SW membrane element.
  • Configuration: Spiral Wound
  • Membrane Polymer: Composite Polyamide
  • Membrane Active Area: 400 ft² (37 m²)
  • Feed Spacer: 34 mil (0.86 mm)
  • Packaging: All membrane elements are supplied with a brine seal, interconnector, and O-rings. Elements are enclosed in a sealed polyethylene bag containing 2% Safeguard® 100 as a preservation solution (or 10-20% CaCl₂ as anti-freezing solution for cold climates), and then packaged in a cardboard box.

Operating limits

  • Maximum Applied Pressure: 600 psig (4.14 MPa)
  • Maximum Operating Temperature: 113 °F (45 °C)
  • pH Range, Continuous (Cleaning): 3-9 (1-11.5)
  • Maximum Pressure Drop for Each Element: 15 psi (0.10 MPa)

Feed water

  • Maximum Chlorine Concentration: < 0.1 ppm
  • Maximum Feedwater Turbidity: 1.0 NTU
  • Maximum Feedwater SDI (15 mins): 5.0
  • Maximum Feed Flow: 85 gpm (19.3 m³/h)
  • Minimum Brine Flow: 12 gpm (2.7 m³/h)
  • Specified Performance Test Conditions:
    • 2000 ppm MgSO₄
    • 110 psig (0.76 MPa) Applied Pressure
    • 77 °F (25 °C) Operating Temperature
    • 15% Permeate Recovery
    • 6.5 - 7.0 pH Range
  • Typical Synthetic Seawater Test Condition:
    • 35,000 ppm NaCl + 8,000 ppm MgSO₄
    • 200 psi (1.4 MPa)
    • 77 °F (25 °C)
    • 15% Permeate Recovery
    • 6.5 – 7.0 feed pH

Product water

  • Specified Performance
    • Permeate Flow: 11,000 gpd (41.6 m³/d)
    • MgSO₄ Rejection: 99.8% (99.6% minimum)
  • Typical Seawater Performance
    • Nominal Permeate Flow: 7,150 gpd (27.0 m³/d)
    • Nominal Chloride Rejection: 25%
    • Nominal Sulfate Rejection: 99.8%

Mechanical / hydraulic

  • Element dimensions (indicative values):
    • A: 40.0 inches (1016 mm)
    • B: 7.89 inches (200 mm)
    • C: 1.125 inches (28.6 mm)