Quay lại Hydranautics Membranes
Hydranautics logo

Tóm tắt tài liệu kỹ thuật

HYDRAcap-MAX-60

Engineering summary from PDF text extraction for HYDRAcap-MAX-60. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product Name: HYDRAcap® MAX 60
  • Configuration: Capillary Ultrafiltration Module
  • Membrane Polymer: TIPS PVDF
  • Nominal Membrane Area: 840 ft² (78 m²)
  • Fiber Dimensions: ID 0.024” (0.6 mm), OD 0.047” (1.2 mm)
  • Pore size: 0.08 micron
  • Operating Mode: Outside to Inside Filtration, Dead End or Cross flow mode
  • Certifications: NSF61, NSF419 (US LT2ESWTR – Public Drinking Water Compliance)

Operating limits

  • Maximum Applied Feed Pressure:
    • 73 psig (5.0 bar) at ≤20 °C
    • 58 psig (4 bar) between 21 – 30 °C
    • 44 psig (3 bar) between 31 – 40 °C
  • Maximum Transmembrane Pressure: 30 psig (2.0 bar)
  • Instantaneous Chlorine Tolerance: 5000 ppm (for 60 minutes or less)
  • Maximum Chlorine Exposure: 1,000,000 ppm-hrs
  • Maximum Feed Turbidity: 300 NTU (Higher values can be treated; consult Hydranautics’ technical staff.)
  • Maximum Operating Temperature: 104 °F (40 °C)
  • pH Operating Range: 2.0 – 11.0
  • Cleaning pH Range: 1.0 – 13.0

Product water

  • Filtrate Flow: 11.7 – 37.9 gpm (2.7 – 8.6 m³/h)
  • Filtrate Turbidity: ≤ 0.10 NTU
  • Bacteria removal: ≥ 4 log
  • Typical Filtrate Flux Range: 20 – 65 gfd (34 – 110 l/m²/h)

Mechanical / hydraulic

  • Dimensions:
    • A: 72.15 inches (1832.6 mm)
    • B: 63.11 inches (1602.9 mm)
    • C: 67.90 inches (1724.7 mm)
  • Pipe connections: 2” Victaulic
  • Dry Weight: 115 lbs (52 kg)
  • Wet Weight: 220 lbs (100 kg)

Process Conditions

  • Air Scour Rate: 7.3 – 9.1 acfm (12.3 – 15.4 m³/h)
  • Air Scour Duration: 120 – 240 seconds
  • Air Scour Frequency: Once every 20 – 60 minutes
  • Maintenance Clean Frequency: 1 – 3 times per day
  • Maintenance Clean Duration: 20 – 30 minutes
  • Disinfection Chemicals: NaOCl, ClO₂, or NH₂Cl
  • Cleaning Chemicals: NaOH, HCl, H₂SO₄, or Citric Acid