Quay lại Filmtec Membranes
DuPont logo

Tóm tắt tài liệu kỹ thuật

XLE-2540

Engineering summary from PDF text extraction for XLE-2540. Verify every value with the OEM datasheet.

Summary

Product identification

  • FilmTec™XLE-2540 (Part Number: 154543)
  • FilmTec™TW30-2540 (Part Number: 80643)

Typical Properties

  • FilmTec™XLE-2540:
    • Feed Spacer Thickness: 28 mil
    • Permeate Flow Rate: 850 gpd (3.2 m³/d)
    • Stabilized Salt Rejection: 99.0%
    • Test Conditions: 77°F (25°C), 15% recovery, 100 psig (6.9 bar) applied pressure, 500 ppm NaCl feed stream.
  • FilmTec™TW30-2540:
    • Feed Spacer Thickness: 28 mil
    • Permeate Flow Rate: 1,000 gpd (3.8 m³/d)
    • Stabilized Salt Rejection: 99.5%
    • Test Conditions: 77°F (25°C), 15% recovery, 225 psig (15.5 bar) applied pressure, 2,000 ppm NaCl feed stream.
  • Permeate flows for individual elements may vary +/-20%.

Mechanical / Hydraulic

  • Element Dimensions (inches (mm)):
    • XLE-2540:
      • A: 40.0 (1,016)
      • B: 1.19 (30.2)
    • TW30-2540:
      • A: 40.0 (1,016)
      • B: 1.19 (30.2)
  • Elements fit nominal 2.5-inch I.D. pressure vessels.

Operating limits

  • Membrane Type: Polyamide Thin-Film Composite
  • Maximum Operating Temperatureª: 113°F (45°C)
  • Maximum Operating Pressure: 600 psig (41 bar)
  • Maximum Feed Flow Rate: 6 gpm (1.4 m³/hr)
  • Maximum Pressure Drop (per element): 13 psig (0.9 bar)
  • Maximum Pressure Drop across an entire pressure vessel (housing): 50 psi (3.4 bar)
  • pH Range:
    • Continuous Operationª: 2 - 11
    • Short-Term Cleaning (30 min.)ᵇ: 1 - 13

ª Maximum temperature for continuous operation above pH 10 is 95ºF (35ºC). ᵇ Refer to Cleaning Guidelines (Form No. 45-D01696-en).

Feed water

  • Maximum Feed Silt Density Index (SDI): SDI 5
  • Free Chlorine Toleranceᶜ: <0.1 ppm

ᶜ Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. Oxidation damage is not covered under warranty.

General Guidelines

  • Keep elements moist at all times after initial wetting.
  • To prevent biological growth during prolonged system shutdowns, it is recommended that membrane elements be immersed in a preservative solution.
  • Avoid static permeate-side backpressure at all times.
  • Avoid any abrupt pressure or cross-flow variations on the spiral elements during start-up, shutdown, cleaning or other sequences.
  • During start-up, feed pressure should be increased gradually over a 30-60 second time frame.
  • During start-up, cross-flow velocity at set operating point should be achieved gradually over 15-20 seconds.
  • The use of this product in and of itself does not necessarily guarantee the removal of cysts and pathogens from water.

Disclaimer

This extraction may miss figures, footnotes, or revisions from the original PDF. Contractual data must match the OEM PDF revision used on the project.