Quay lại CMS Membranes
Toray logo

Tóm tắt tài liệu kỹ thuật

CSM UE1810

Engineering summary from PDF text extraction for CSM UE1810. Verify every value with the OEM datasheet.

Summary

Product identification

  • Model: UE1810
  • Application: UF element for residential use
  • Certification: Certified to NSF/ANSI 58
  • Membrane Type: Thin-Film Composite
  • Membrane Material: Polysulfone (PSF)
  • Element Configuration: Spiral-Wound, Tape Wrapping
  • Permeate Flow Rate: 200 GPD (757 L/day)
  • Molecular Weight Cut Off (MWCO): 100K
  • Test Conditions: Stated product performance is based on data taken after 30 minutes of operation at the following test Conditions: Pure water (2 MΩ) at 20 psig applied pressure; 100% recovery; 77℉ (25℃). Permeate flow rate for each element may vary ±15%.
  • Supply Condition: Elements are supplied as Wet-type, soaked in a preservative solution (1.0% food grade SBS) and vacuum sealed in a poly bag. All elements are individually boxed.

Operating limits

  • Max. Operating Pressure: 125 psi (0.86 MPa)
  • Max. Feed Flow Rate: 2 gpm (0.45 m³/hr)
  • Max. Operating Temperature: 113℉ (45℃)
  • Operating pH Range: 3.0 – 10.0
  • Max. Turbidity: 1.0 NTU
  • Max. SDI (15 min): 5.0

Mechanical / hydraulic

  • Model: UE1810
    • A: 0.67 inch (17 mm)
    • B: 0.55 inch (14 mm)
    • C: 10.08 inch (256 mm)
    • D: 0.98 inch (25 mm)
    • E: 1.77 inch (45 mm)

General handling procedures

  • Elements contained in boxes must be kept dry at room temperature (7–32°C; 40–95°F) and should not be stored in direct sunlight.
  • For WET-TYPE elements, the preservative solution (1% sodium metabisulfite solution) is added to prohibit the growth of micro-organisms.
  • Permeate from the first hour of operation should be discarded.
  • Keep elements moist at all times after initial wetting.
  • Avoid excessive pressure and flow spikes.
  • Only use chemicals compatible with the membrane elements and components. Use of such chemicals may void the element limited warranty.
  • Permeate pressure must always be equal to or less than the feed/concentrate pressure. Damage caused by permeate back pressure voids the element limited warranty.

Disclaimer: Extraction may miss figures, footnotes, or revisions; contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Nội dung tổng hợp từ tài liệu kỹ thuật công khai nhằm tra cứu và so sánh sơ bộ. Bản tóm tắt không thay thế bảng dữ liệu hiện hành được nhà sản xuất chứng nhận. Kiểm tra phiên bản và giới hạn thiết kế trước khi sử dụng.