CSM RE8040-BLF440
Engineering summary from PDF text extraction for CSM RE8040-BLF440. Verify every value with the OEM datasheet.
Summary
Product identification
The RE8040-BLF440 is an ultra-low pressure grade reverse osmosis (RO) element designed for low total dissolved solids (TDS) water. It is suitable for Industrial and Municipal applications. This product is certified to NSF/ANSI/CAN 61.
General Features
- Ultra-Low-Energy Consumption
- Extended effective membrane area
- Membrane Type: Thin-Film Composite
- Membrane Material: Polyamide (PA)
- Element Configuration: Spiral-Wound, FRP Wrapping
Performance Specifications
Test Conditions:
- NaCl solution: 500 mg/L
- Applied pressure: 100 psig (0.69 MPa)
- Recovery: 15%
- Temperature: 77℉ (25℃)
- pH: 6.5–7.0
- Permeate flow rate for each element may vary +25% / -15%.
Performance:
- Permeate Flow Rate: 12,650 GPD (47.9 m³/day)
- Nominal Salt Rejection: 99.2% (Minimum 99.0%)
- Effective Membrane Area: 440 ft² (40.9 m²)
Mechanical / Hydraulic
- Model Name: RE8040-BLF440
- Dimensions:
- A: 40.0 inch (1,016 mm)
- B: 7.9 inch (200 mm)
- C: 1.12 inch (28.5 mm)
- Weight: 15kg
- Part Numbers:
- Inter-Connector: SWA01049
- Brine Seal: SWA01043
- Each membrane element is supplied with one interconnector (coupler) and four O-rings.
- All RE8040 elements fit nominal 8.0 inch (203.2 mm) I.D. pressure vessels.
- The element shell is FRP (Fiber Reinforced Plastic).
Operating limits
- Max. Pressure Drop / Element: 15 psi (0.10 MPa)
- Max. Pressure Drop / 240” Vessel: 60 psi (0.41 MPa)
- Max. Operating Pressure: 600 psi (4.14 MPa)
- Max. Feed Flow Rate: 75 gpm (17.0 m³/hr)
- Min. Concentrate Flow Rate: 16 gpm (3.6 m³/hr)
- Max. Operating Temperature: 113°F (45°C)
- Operating pH Range: 2.0 – 11.0
- CIP pH Range: 1.0 – 13.0
- Max. Turbidity: 1.0 NTU
- Max. SDI (15 min): 5.0
- Max. Chlorine Concentration: < 0.1 mg/L
General Handling Procedures
- Elements in boxes must be kept dry at room temperature (7–32°C; 40–95°F) and not stored in direct sunlight.
- For wet-type elements, a preservative solution (1% sodium metabisulfite solution) is added to prohibit microbial growth.
- Permeate from the first hour of operation should be discarded.
- Stabilized salt rejection is generally achieved within 1–48 hours of continuous use.
- Keep elements moist at all times after initial wetting.
- Avoid excessive pressure and flow spikes.
- Only use chemicals compatible with the membrane elements and components. Use of incompatible chemicals may void the element's limited warranty.
- Permeate pressure must always be equal to or less than the feed/concentrate pressure. Damage caused by permeate back pressure voids the element's limited warranty.
- The element shell is FRP. Be aware of glass fiber strands and use safety equipment.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.