Product identification
The CSM RE4021-BLF is an ultra-low pressure grade reverse osmosis (RO) element designed for low total dissolved solids (TDS) water applications.
- General Features: Ultra-Low-Energy Consumption
- Membrane Type: Thin-Film Composite
- Membrane Material: Polyamide (PA)
- Element Configuration: Spiral-Wound, FRP Wrapping
Performance
Performance is measured under the following test conditions:
- NaCl solution: 500 mg/L
- Applied pressure: 100 psig (0.69 MPa)
- Recovery: 8%
- Temperature: 77℉ (25℃)
- pH: 6.5–7.0
- Permeate flow rate for each element may vary +25 / -25%.
General Features:
- Permeate Flow Rate: 1,200 GPD (4.5 m³/day)
- Nominal Salt Rejection: 99.2% (Minimum 99.0%)
- Effective Membrane Area: 35ft² (3.3 m²)
Operating limits
- Max. Pressure Drop / Element: 15 psi (0.10 MPa)
- Max. Pressure Drop / 240” Vessel: 60 psi (0.41 MPa)
- Max. Operating Pressure: 600 psi (4.14 MPa)
- Max. Feed Flow Rate: 18 gpm (4.09 m³/hr)
- Min. Concentrate Flow Rate: 4 gpm (0.91 m³/hr)
- Max. Operating Temperature: 113°F (45°C)
- Operating pH Range: 2.0 – 11.0
- CIP pH Range: 1.0 – 13.0
- Max. Turbidity: 1.0 NTU
- Max. SDI (15 min): 5.0
- Max. Chlorine Concentration: < 0.1 mg/L
Mechanical / hydraulic
- Model Name: RE4021-BLF
- Length (A): 21.0 inch (533.4 mm)
- Diameter (B): 3.9 inch (99.0 mm)
- Inner Diameter (C): 0.75 inch (19.1 mm)
- Outer Diameter (D/E): 1.05 inch (26.7 mm)
- Inter-Connector Part Number: SWA01050
- Brine Seal Part Number: SWA01046
- Each membrane element is supplied with one interconnector (coupler) and four O-rings.
- All RE4021 elements fit nominal 4.0 inch (101.6 mm) I.D. pressure vessels.
- The element shell is Fiber Reinforced Plastic (FRP).
General Handling Procedures
- Elements must be kept dry at room temperature (7–32°C; 40–95°F) and should not be stored in direct sunlight.
- For WET-TYPE elements, a preservative solution (1% sodium metabisulfite solution) is added to inhibit microbial growth.
- Permeate from the first hour of operation should be discarded.
- Stabilized salt rejection is generally achieved within 1–48 hours of continuous use.
- Keep elements moist at all times after initial wetting.
- Avoid excessive pressure and flow spikes.
- Only use chemicals compatible with the membrane elements and components; incompatible chemicals may void the limited warranty.
- Permeate pressure must always be equal to or less than the feed/concentrate pressure; damage caused by permeate back pressure voids the limited warranty.
- Be aware of glass fiber strands from the FRP shell and use safety equipment during handling.
Certifications
- Certified to NSF/ANSI/CAN 61