ICT-5

Engineering summary from PDF text extraction for ICT-5. Verify every value with the OEM datasheet.

Summary

Product identification

Ozone generator: ICT 05-10

Operating limits

  • Ozone production:
    • Concentration, max: 240 g/Nm³
  • Feed gas (Oxygen):
    • Purity: 99% (max dew point -60 °C / -140 °F)
    • Inlet pressure: 2 – 4 bar g (29.0 - 58.0 psig)
    • Internal pressure: 0.8 – 1.2 bar g (11.6 - 17.4 psig)
  • Cooling water:
    • Quality: Fresh, filtered & clean
    • Inlet pressure: 1 – 5 bar g (14.5 - 72.5 psig)
    • Temperature: 5 -12 °C (41- 53.6 °F)
    • Flow: 0.5 l/min

Electrical

  • Voltage rating: 230 VAC, 50 Hz (Optional: 115 VAC, 60 Hz)
  • Power consumption, max: 125 W

Mechanical / hydraulic

  • Cabinet: Stainless steel
  • Connections:
    • O₂ in: 8 mm, push in
    • O₃ out: 8 mm, tube fitting
    • Cooling water in: 8 mm, push in
    • Cooling water out: 8 mm, push in
  • Dimensions (H x W x D): 300 x 200 x 155 mm (11.8 x 7.9 x 6.1 in)
  • Weight: 8.5 kg (18.7 lb)
  • IP class: 64

Specifications by model

ModelNominal O₃ prod. [g/h]O₃ concentration [g/Nm³]O₂ flow [g/Nm³]O₂ pressure, max [g/Nm³]
ICT-50-51350.61.2 / 17.4
ICT-5LAB0-51350.61.2 / 17.4
ICT-100-101352.51.2 / 17.4

Advantages

  • Low energy consumption
  • High ozone concentration
  • Very low noise level
  • Compact design
  • Easy to maintain
  • Alarm signal output (relay)
  • 4-20 mA analogue input