DCT-500

Engineering summary from PDF text extraction for DCT-500. Verify every value with the OEM datasheet.

Summary

Product identification

The DCT-series ozone generators are based on a modular approach, housed in three stainless steel cabinets. The system includes a PLC, power supply, and ozone generator parts on a rack.

Operating limits

  • Ozone concentration, max: 265 g/Nm³
  • Feed gas (Oxygen) pressure, internal: 1 - 2.5 bar g (14.5 - 36.3 psig)
  • Feed gas (Oxygen) pressure, in, max: 5 bar g (72.5 psig)
  • Main cooling water pressure, max: 4 bar (58.0 psig)
  • Pressurized cooling water pressure: 3.4 - 3.6 bar (49.3 - 52.2 psig)

Feed water

Oxygen

  • Purity: 99%
  • Max dew point: -60 °C (-140 °F)

Main cooling water

  • Quality: Fresh, filtered & clean
  • Temperature: 5 -12 °C (41 - 53.6 °F)

Pressurized cooling water

  • Quality: Drinking water
  • Flow rate: < 1 l/min

Product water

Ozone production

ModelNominal O₃ prod. [g/h]O₃ concentration [g/Nm³]At feed gas flow [l/min]Cooling water, min. [l/min]Power consumption [W]
DCT-5000-50021540153.8
DCT-10000-1,000140120307.5
DCT-20000-2,0001402406015
DCT-30000-3,0001403609022.5
DCT-40000-4,00014048012030
DCT-50000-5,00014060015037.5

Electrical

  • Voltage: 400 VAC, 50 Hz

Mechanical / hydraulic

Connections

  • O₂ in: 12 mm, tube fitting
  • O₃ out: 12 mm, tube fitting
  • Main cooling, in: 1” (BSP)
  • Main cooling, out: 1” (BSP)
  • Pressurized cooling: 10 mm, tube fitting

Dimensions

  • PLC: 500 x 400 x 200 mm (19.7 x 15.7 x 7.9 in)
  • Power supply: 500 x 400 x 200 mm (19.7 x 15.7 x 7.9 in)
  • O₃-generator: 800 x 800 x 300 mm (31.5 x 31.5 x 11.8 in)
  • Integrated on rack: 1,600 x 800 x 700 mm (63.0 x 31.5 x 27.6 in)

Weight

ModelWeight [kg/lb]No. of units
DCT-500110 / 242.51
DCT-1000110 / 242.51
DCT-2000220 / 485.02
DCT-3000330 / 727.53
DCT-4000440 / 970.04
DCT-5000550 / 1,212.55

Enclosure

  • IP class: 64

Advantages

  • Modular built system
  • Low noise level
  • Compact design
  • Easy to maintain
  • Alarm signal output (relay)
  • System parameters displayed on the PLC

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.