Quay lại Rohm & Haas
Rohm & Haas logo

Tóm tắt tài liệu kỹ thuật

Amberlite IRC747

PDF datasheet mirror for Amberlite IRC747 (Rohm & Haas). Verify with OEM before design.

Summary

Product identification

AMBERLITE® IRC747 is an industrial grade chelating resin with a macroporous structure.

Properties

  • Matrix: Styrene divinylbenzene copolymer
  • Functional groups: -CH₂-NH-CH₂-PO₃Na₂
  • Physical form: Beige beads
  • Ionic form as shipped: Na⁺
  • Total exchange capacity: ≥ 1.75 eq/L (Na⁺ form)
  • Moisture holding capacity: 64 to 69 % (Na⁺ form)
  • Specific gravity: 1.10 to 1.14 (Na⁺ form)
  • Shipping weight: 755 g/L (47.1 lb/ft³)
  • Harmonic mean size: 0.520 - 0.660 mm
  • Uniformity coefficient: ≤ 1.8
  • Fine contents: < 0.300 mm : 2.0% max
  • Coarse beads: > 1.000 mm : 5.0% max
  • Maximum reversible swelling: H⁺ → Na⁺ : 45 %

Suggested Operating Conditions

  • Maximum operating temperature: 80°C (175 °F)
  • Minimum bed depth: 700 mm (28 inches)
  • Service flow rate: up to 40 BV/h (5 gpm/ft³)
  • Regeneration: HCl (1N to 2N)
  • Conversion to Na⁺ form: NaOH (1N to 2N)
  • Operating pH: Function of applications

Performance

Characteristic Reaction

R-CH₂-NH-CH₂-PO₃Na₂ + M²⁺ → R-CH₂-NH-CH₂-PO₃M + 2 Na⁺

Relative Affinity

The relative affinity of this resin for the various cations decreases in the order: Pb²⁺ > Cu²⁺ > Zn²⁺ > Mg²⁺ > Ca²⁺ > Cd²⁺ > Ni²⁺ > Co²⁺ > Sr²⁺ > Ba²⁺

Operating pH Range

The resin can operate in a neutral, acidic, or alkaline medium. Recommended minimum pH values are:

  • Cations: Cu²⁺, Zn²⁺, Cd²⁺, Mg²⁺, Pb²⁺, Ca²⁺, Ni²⁺, Co²⁺
  • Minimum pH: 2, 2.5, 3, 4.5 (corresponding to the listed cations)

Applications

  • Brine Purification: Removal of Ca, Mg, and other metals from concentrated brine (e.g., chlor-alkali electrolysis).
  • Zinc Separation: Separation of zinc from various media.
  • Lead Separation: Separation of lead from industrial effluents.

Hydraulic Characteristics

Refer to the original datasheet for figures illustrating bed expansion as a function of backwash flow rate and temperature, and pressure drop in brine as a function of linear velocity and temperature.

Limits of Use

AMBERLITE IRC747 is suitable for industrial uses. For pharmaceutical, food processing, or potable water applications, consult Rohm and Haas.


Disclaimer: This extracted summary may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Nội dung tổng hợp từ tài liệu kỹ thuật công khai nhằm tra cứu và so sánh sơ bộ. Bản tóm tắt không thay thế bảng dữ liệu hiện hành được nhà sản xuất chứng nhận. Kiểm tra phiên bản và giới hạn thiết kế trước khi sử dụng.