
Tóm tắt tài liệu kỹ thuật
MBD-15-LTOC
PDF datasheet mirror for MBD-15-LTOC (ResinTech). Verify with OEM before design.
Summary
Product identification
- Product Name: MBD-15-LTOC
- Product Type: MIXED BED
- Product Line: ResinTech, Inc.®
- Grade: HIGH CAPACITY LOW TOC MIXED BED POLYSTYRENIC GEL H / OH FORM
- Revision: 1.1
ResinTech MBD-15-LTOC is a mixture of a dark-colored hydrogen form cation resin and a hydroxide form type 1 strong base anion resin in a 1:1 equivalent ratio. The LTOC grade is functionally tested to produce > 18 megohm resistivity and under 10 ppb of TOC.
Applications
- High Purity DI Water
- Portable Exchange Deionization (PEDI) - Low TOC
- Cartridge Applications
- In Place Regeneration
Typical Properties & Physical Characteristics
- Polymer Matrix: Styrenic Gel
- Ionic Form: Hydrogen & Hydroxide
- Functional Group: Sulfonic Acid / Trimethylamine
- Physical Form: Spherical Beads
- Particle Size: 16 to 50 US Mesh (297 - 1190 μm)
- % < 50 mesh (300µm): < 1%
- Reversible Swelling (H/OH to Na/Cl): -15% to -17%
- Temperature Limit: 140°F (60°C)
- Capacity (meq/mL): 0.6
- Moisture Retention: 53% to 65%
- Shipping Weight: 42 - 44 lbs/ft³ (673 - 705 g/L)
- Color: Brown / Black & Amber
- Regenerability: Yes
Suggested Operating Conditions
- Maximum continuous temperature: 140°F
- Maximum intermittent temperature: 180°F
- Minimum bed depth: 24 inches
- Backwash expansion: 50 to 100 percent
- Maximum pressure loss: 25 psi
- Operating pH range: 2 to 12 SU
- Service flow rate (Working): 1 to 5 gpm per cu. ft.
- Service flow rate (Polishing): 3 to 15 gpm per cu. ft.
Packaging Options
- 500 ml samples
- 1 ft³ bags
- 1 ft³ boxes
- 1 ft³ drums
- 7 ft³ drums
- 42 ft³ supersacks
Technical Data
Backwash Expansion
| gpm / sq.ft. | 40˚F | 60˚F | 80˚F | 100˚F |
|---|---|---|---|---|
| 0.0 | 0 | 0 | 0 | 0 |
| 1.0 | 20 | 40 | 60 | 80 |
| 2.0 | 100 |
Pressure Loss
| gpm / sq.ft. | 40˚F | 60˚F | 80˚F | 100˚F |
|---|---|---|---|---|
| 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| 0.5 | ||||
| 1.0 | ||||
| 1.5 | ||||
| 2.0 | ||||
| 2.5 | ||||
| 3.0 | ||||
| 5.0 | 15.0 | |||
| 10.0 | 20.0 |
Throughput Capacity (Gal/cu. ft.)
| TDS (ppm as CaCO₃) | Conductivity (uS/cm) | No CO₂ or SiO₂ | 5 ppm CO₂ or SiO₂ | 10 ppm CO₂ or SiO₂ |
|---|---|---|---|---|
| 2/5 | 111,834 | 31,953 | 18,639 | |
| 5/12.5 | 44,734 | 22,367 | 14,911 | |
| 10/25 | 22,367 | 14,911 | 11,183 | |
| 20/50 | 11,183 | 8,947 | 7,456 | |
| 50/125 | 4,473 | 4,067 | 3,728 | |
| 100/250 | 2,237 | 2,130 | 2,033 | |
| 200/500 | 1,118 | 1,091 | 1,065 | |
| 500/1250 | 447 | 443 | 439 | |
| 1000/2500 | 224 | 223 | 221 |
Note: Mixed Bed throughput capacity is to a 1 µS/cm endpoint. TDS is based on NaCl. Capacity is based on virgin resin.
Disclaimer: This extracted summary may not include all figures, footnotes, or revisions. Contractual data must match the official OEM PDF revision used for the project.
Official datasheet (PDF)
Nội dung tổng hợp từ tài liệu kỹ thuật công khai nhằm tra cứu và so sánh sơ bộ. Bản tóm tắt không thay thế bảng dữ liệu hiện hành được nhà sản xuất chứng nhận. Kiểm tra phiên bản và giới hạn thiết kế trước khi sử dụng.